Literature DB >> 28043075

An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics.

Byung Hyun Park1, Seung Jun Oh1, Jae Hwan Jung1, Goro Choi1, Ji Hyun Seo1, Do Hyun Kim1, Eun Yeol Lee2, Tae Seok Seo3.   

Abstract

Point-of-care (POC) molecular diagnostics plays a pivotal role for the prevention and treatment of infectious diseases. In spite of recent advancement in microfluidic based POC devices, there are still rooms for development to realize rapid, automatic and cost-effective sample-to-result genetic analysis. In this study, we propose an integrated rotary microfluidic system that is capable of performing glass microbead based DNA extraction, loop mediated isothermal amplification (LAMP), and colorimetric lateral flow strip based detection in a sequential manner with an optimized microfluidic design and a rotational speed control. Rotation direction-dependent coriolis force and siphon valving structures enable us to perform the fluidic control and metering, and the use of the lateral flow strip as a detection method renders all the analytical processes for nucleic acid test simplified and integrated without the need of expensive instruments or human intervention. As a proof of concept for point-of-care DNA diagnostics, we identified the food-borne bacterial pathogen which was contaminated in water or milk. Not only monoplex Salmonella Typhimurium but also multiplex Salmonella Typhimurium and Vibrio parahaemolyticus were analysed on the integrated rotary genetic analysis microsystem with a limit of detection of 50 CFU in 80min. In addition, three multiple samples were simultaneously analysed on a single device. The sample-to-result capability of the proposed microdevice provides great usefulness in the fields of clinical diagnostics, food safety and environment monitoring.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Centrifugal microdevice; Lateral flow strip detection; Loop-mediated isothermal amplification; Point-of-care diagnostics; Solid-phase DNA extraction

Mesh:

Substances:

Year:  2016        PMID: 28043075     DOI: 10.1016/j.bios.2016.11.063

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  31 in total

Review 1.  Loop Mediated Isothermal Amplification: A Promising Tool for Screening Genetic Mutations.

Authors:  Arjuna Srividya; Biswajit Maiti; Anirban Chakraborty; Gunimala Chakraborty
Journal:  Mol Diagn Ther       Date:  2019-12       Impact factor: 4.074

2.  Nucleic acid lateral flow assay for simultaneous detection of hygiene indicator bacteria.

Authors:  Ji Min Kim; Jung Soo Park; Tae Hwi Yoon; Junghun Park; Ki Soo Park
Journal:  Anal Bioanal Chem       Date:  2021-06-16       Impact factor: 4.142

3.  Simultaneous detection of multiple HPV DNA via bottom-well microfluidic chip within an infra-red PCR platform.

Authors:  Wenjia Liu; Antony Warden; Jiahui Sun; Guangxia Shen; Xianting Ding
Journal:  Biomicrofluidics       Date:  2018-03-14       Impact factor: 2.800

4.  Colorimetric detection of DNA at the nanomolar level based on enzyme-induced gold nanoparticle de-aggregation.

Authors:  Qingling Liu; Li Li; Yan Zhao; Zhengbo Chen
Journal:  Mikrochim Acta       Date:  2018-05-15       Impact factor: 5.833

Review 5.  Interfacing Pathogen Detection with Smartphones for Point-of-Care Applications.

Authors:  Xiong Ding; Michael G Mauk; Kun Yin; Karteek Kadimisetty; Changchun Liu
Journal:  Anal Chem       Date:  2018-12-03       Impact factor: 6.986

Review 6.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

Review 7.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

8.  One-Step Nucleic Acid Purification and Noise-Resistant Polymerase Chain Reaction by Electrokinetic Concentration for Ultralow-Abundance Nucleic Acid Detection.

Authors:  Wei Ouyang; Jongyoon Han
Journal:  Angew Chem Int Ed Engl       Date:  2020-04-30       Impact factor: 15.336

9.  Graphene oxide and enzyme-assisted dual-cycling amplification method for sensitive fluorometric determination of DNA.

Authors:  Idorenyin Iwe; Zhigang Li; Jiahao Huang
Journal:  Mikrochim Acta       Date:  2019-10-25       Impact factor: 5.833

Review 10.  Integrated microfluidic systems with sample preparation and nucleic acid amplification.

Authors:  Juxin Yin; Yuanjie Suo; Zheyu Zou; Jingjing Sun; Shan Zhang; Beng Wang; Yawei Xu; Diane Darland; Julia Xiaojun Zhao; Ying Mu
Journal:  Lab Chip       Date:  2019-07-31       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.