The use of pulse oximeters as a non-invasive, real time and online method for the continuous monitoring of oxygen saturation is discussed and compared to other methods like hemoreflectometry, and blood gas analysis. Analyses of linear regression show extraordinarily good correlations between all three monitoring systems. Pulse oximetry and hemoreflectometry on the one hand and blood gas analysis on the other hand sometimes show quite differing values of oxygen saturation. This phenomenon is due to the fact that the measuring methods are based on different working principles as well as it can be explained by the various hemoglobin-types. The pulse rate also measured by the pulse oximeter is nearly completely identical to the heart rate of the ECG. A slight temporal delay between the two acoustic signals is noticed and justified. Pulse oximetry seems to be superior to other oxygen monitoring systems because of its continuous noninvasive measuring technique.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2803212

Source DB:  PubMed          Journal:  Berl Munch Tierarztl Wochenschr        ISSN: 0005-9366            Impact factor:   0.328


  5 in total

1.  Anesthetic Effects of Intramuscular Alfaxalone-Ketamine in Naked Mole Rats (Heterocephalus glaber).

Authors:  Neta Ambar; David Eshar; Trenton C Shrader; Hugues Beaufrère
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-07-17       Impact factor: 1.232

2.  Effects of medetomidine-midazolam-fentanyl IV bolus injections and its reversal by specific antagonists on cardiovascular function in rabbits.

Authors:  Christine Baumgartner; Melanie Bollerhey; Johanna Ebner; Tibor Schuster; Julia Henke; Wolf Erhardt
Journal:  Can J Vet Res       Date:  2010-10       Impact factor: 1.310

3.  Effects of ketamine-xylazine intravenous bolus injection on cardiovascular function in rabbits.

Authors:  Christine Baumgartner; Melanie Bollerhey; Johanna Ebner; Lién Laacke-Singer; Tibor Schuster; Wolf Erhardt
Journal:  Can J Vet Res       Date:  2010-07       Impact factor: 1.310

4.  Accuracy of pulse oximetry and capnography in healthy and compromised horses during spontaneous and controlled ventilation.

Authors:  Judith Koenig; Wayne McDonell; Alexander Valverde
Journal:  Can J Vet Res       Date:  2003-07       Impact factor: 1.310

5.  Assessment of clinical application of pulse oximetry probes in llamas and alpacas.

Authors:  Tamara L Grubb; David E Anderson
Journal:  Vet Med Sci       Date:  2017-07-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.