Literature DB >> 28024818

Effect of production method on surface roughness, marginal and internal fit, and retention of cobalt-chromium single crowns.

Nils Lövgren1, Rikard Roxner2, Susanne Klemendz2, Christel Larsson3.   

Abstract

STATEMENT OF PROBLEM: New production methods have been developed for metal-ceramic restorations. Different production methods may show different surface roughness and fit, which may affect retention and long-term success.
PURPOSE: The purpose of this in vitro study was to examine 3 different production methods with regard to surface roughness, marginal and internal fit, and retention of cobalt-chromium alloy single-crown copings.
MATERIAL AND METHODS: A master abutment of a premolar mandibular tooth preparation with 4-mm height and a 0.6-mm deep 120-degree chamfer finish line with a 12-degree angle of convergence was replicated in die stone and scanned. Thirty-six cobalt-chromium alloy copings were produced using 3 different production techniques. Twelve copings were produced by laser-sintering, 12 by milling, and 12 by milled wax/lost wax. The surface microstructure of 2 copings in each group was analyzed using interferometry. The remaining 10 copings in each group were used to evaluate marginal and internal fit by using an impression material replica method, and retention was evaluated by using a uniaxial tensile force pull-off test. The copings from each test group were cemented with zinc phosphate cement onto resin abutments. Statistical analyses of differences in marginal and internal fit were performed using 1-way ANOVA and the Mann-Whitney U test. Differences in surface topography were analyzed with the Kruskal-Wallis and Mann-Whitney U tests for nonparametric data. Differences in retentive values were analyzed using the Mann-Whitney U test for nonparametric data (all α=.05).
RESULTS: Differences in surface microstructure were seen. The laser-sintered copings showed increased surface roughness compared with milled and milled wax/lost wax copings. Differences in marginal and internal fit were noted. Laser-sintered showed significantly smaller spaces between coping and abutment than milled wax/lost wax copings (P=.003). At the margins, laser-sintered copings showed significantly smaller spaces than either the milled wax/lost wax group (P=.002) or the milled group (P=.002). At the chamfer, laser-sintered copings showed significantly smaller spaces than milled wax/lost wax copings (P=.005). At the center of the axial walls, laser-sintered copings showed significantly smaller spaces than those in the milled wax/lost wax (P=.004) and milled copings (P=.005). No significant differences were noted between milled and milled wax/lost wax copings (P>.05). No significant differences were detected regarding retentive forces in the pull-off tests (P>.05).
CONCLUSIONS: Laser-sintered Co-Cr crown copings showed increased surface roughness and better internal and marginal fit than copings produced by milling or milled wax/lost wax technique. However, the crown pull-off tests did not reveal any significant differences.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 28024818     DOI: 10.1016/j.prosdent.2016.09.025

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  [Influence of preparation height and cement space on the fit and retention of computer aided design/computer aided manufacturing zirconia crown].

Authors:  Shuang Xi; Zi-Xiao Wu; Cui-Cui Gao; Yu-Chen Meng; Dan-Dan Pei; Yi Lu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-06-01

2.  Assessment of internal fit and micro leakage of conventionally fabricated ceramometallic restoration versus CAD wax and press veneering (in-vitro study).

Authors:  Fatema Khaled Mansour; Rabab Mohammed Ibrahim; Hoda Mansour; Ahmed Mohamed Hamdy
Journal:  BDJ Open       Date:  2021-05-10

3.  Comparison of Retention and Seating of Implant-Supported Hard and Soft Metal Copings.

Authors:  Safoura Ghodsi; Anahita Fayyazi; Maryam Ghiasi; Ahmad Rohanian; Marzieh Alikhasi
Journal:  Front Dent       Date:  2020-10-26

4.  An In Vitro Assessment of Marginal Accuracies in Copings Fabricated With Two Dissimilar Alloys: An Original Research Study.

Authors:  Prince Kumar; Nikhat Fatima; Ganesh Ramesh; Harsh Priyank; Ankita Shrivastav; Susovan Giri; Hiroj Bagde
Journal:  Cureus       Date:  2022-08-20

Review 5.  3D Printing in Digital Prosthetic Dentistry: An Overview of Recent Developments in Additive Manufacturing.

Authors:  Josef Schweiger; Daniel Edelhoff; Jan-Frederik Güth
Journal:  J Clin Med       Date:  2021-05-07       Impact factor: 4.964

6.  Influence of Material Selection on the Marginal Accuracy of CAD/CAM-Fabricated Metal- and All-Ceramic Single Crown Copings.

Authors:  Matthias Rödiger; Lea Schneider; Sven Rinke
Journal:  Biomed Res Int       Date:  2018-03-22       Impact factor: 3.411

7.  Influence of the CAD-CAM Systems on the Marginal Accuracy and Mechanical Properties of Dental Restorations.

Authors:  Roberto Padrós; Luís Giner; Mariano Herrero-Climent; Carlos Falcao-Costa; José-Vicente Ríos-Santos; Francisco Javier Gil
Journal:  Int J Environ Res Public Health       Date:  2020-06-15       Impact factor: 3.390

Review 8.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.

Authors:  Per Svanborg; Lars Hjalmarsson
Journal:  Biomater Investig Dent       Date:  2020-01-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.