Literature DB >> 32573132

[Influence of preparation height and cement space on the fit and retention of computer aided design/computer aided manufacturing zirconia crown].

Shuang Xi1, Zi-Xiao Wu1, Cui-Cui Gao1, Yu-Chen Meng1, Dan-Dan Pei1, Yi Lu1.   

Abstract

OBJECTIVE: To investigate the effects of preparation height and cement space on the fit and retention of computer aided design (CAD)/computer aided manufacturing (CAM) zirconia crown, and to provide reference for the clinical design and fabrication of CAD/CAM crowns.
METHODS: 3D printing system was used to fabricate resin abutment teeth with convergence angle of 2° and height of 1-3 mm. The models' optical impressions were collected by the three-shape scanner. Then, the cement spaces were set by Cradle CAD/CAM system at 10-50 μm to create an all-ceramic zirconia crown. The fit of the crowns was measured by using silicone rubber interstitial impression method. The retention of the crowns was measured by pull-off test with uniaxial tensile force after the crown was bonded. The data were analyzed by SPSS 22.0 soft-ware.
RESULTS: When the preparation height was fixed, the fitness values of different cement space groups have statistical difference (P<
0.05), whereas the retention values of different cement space groups have no statistical difference (P>0.05). The fitness values of different preparation height groups have no statistical difference (P>0.05), and the retention values of different preparation height groups have statistical difference (P<0.05) when the cement space was fixed. No interaction was observed between the cement space and the preparation height (P>0.05).
CONCLUSIONS: When cradle CAD/CAM system is used to create a full crown in the clinic, the preparation height should be set to more than 3 mm, and the cement space should be set at 30 μm.

Entities:  

Keywords:  cement space; computer aided design/computer aided manu­facturing zirconia crown; fit; preparation height; retention

Mesh:

Substances:

Year:  2020        PMID: 32573132      PMCID: PMC7296370          DOI: 10.7518/hxkq.2020.03.006

Source DB:  PubMed          Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi        ISSN: 1000-1182


  25 in total

1.  Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns.

Authors:  Shu-Hui Mou; Tsongi Chai; Juo-Song Wang; Yuh-Yuan Shiau
Journal:  J Prosthet Dent       Date:  2002-03       Impact factor: 3.426

2.  [The experimental study of the relationship between preparation height and retention of complete crowns].

Authors:  Li-Ping Chen; Nan Hua; Yan Ge; Jing Zhuang; Qiong Qian
Journal:  Shanghai Kou Qiang Yi Xue       Date:  2004-08

3.  Mixing variables of zinc phosphate cement and their influence on the seating and retention of complete crowns.

Authors:  S F Rosenstiel; A G Gegauff
Journal:  Int J Prosthodont       Date:  1989 Mar-Apr       Impact factor: 1.681

4.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

5.  The effect of surface roughness of crown preparations on retention of cemented castings.

Authors:  D A Felton; B E Kanoy; J T White
Journal:  J Prosthet Dent       Date:  1987-09       Impact factor: 3.426

6.  Accuracy of ceramic restorations made with two CAD/CAM systems.

Authors:  Tamer A Hamza; Hesham A Ezzat; Mohamed Mahmoud Khalil El-Hossary; Hesham Abd El Megid Katamish; Tamer E Shokry; Stephen F Rosenstiel
Journal:  J Prosthet Dent       Date:  2013-02       Impact factor: 3.426

7.  The influence of surface roughness on the retentive ability of two dental luting cements.

Authors:  G Oilo; K D Jørgensen
Journal:  J Oral Rehabil       Date:  1978-10       Impact factor: 3.837

8.  Effect of increasing cement space on cementation of artificial crowns.

Authors:  P R Wilson
Journal:  J Prosthet Dent       Date:  1994-06       Impact factor: 3.426

9.  The effects of die relief agent on the retention of full coverage castings.

Authors:  S G Vermilyea; M J Kuffler; E F Huget
Journal:  J Prosthet Dent       Date:  1983-08       Impact factor: 3.426

10.  Comparative evaluation of marginal fit and axial wall adaptability of copings fabricated by metal laser sintering and lost-wax technique: An in vitro study.

Authors:  Bhushan Satish Gaikwad; Girish Nazirkar; Rajani Dable; Shailendra Singh
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.