Tono-Pen estimation of intraocular pressure through bandage contact lenses.

J A Khan1, B A LaGreca.   

Abstract

The Tono-Pen was used to determine the reliability of intraocular pressure readings obtained through bandage contact lenses in 48 eyes of 24 healthy volunteers. The mean difference between readings obtained before lens insertion and readings obtained with the lens in place was 0.27 mm Hg and was not statistically significant (P greater than .2). The mean difference between readings obtained with the lens in place and readings obtained after lens removal was 0.85 mm Hg and was statistically significant (P less than .01). Ninety-five percent confidence intervals suggest that the true difference between mean Tono-Pen readings obtained with and without the lens in place ranges from -0.3 to +1.5 mm Hg. Our results suggest that the Tono-Pen is probably an effective way to estimate intraocular pressure through bandage contact lenses, with a probable true mean difference of less than 1.5 mm Hg and a standard deviation of about 2 mm Hg.

Entities:  

Mesh:

Year:  1989        PMID: 2801861     DOI: 10.1016/s0002-9394(14)73310-0

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  5 in total

1.  Intraocular Pressure After 2 Hours of Small-Diameter Scleral Lens Wear.

Authors:  Cherie B Nau; Muriel M Schornack; Jay W McLaren; Arthur J Sit
Journal:  Eye Contact Lens       Date:  2016-11       Impact factor: 2.018

2.  The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses.

Authors:  S Boyraz; I Güngör
Journal:  Ir J Med Sci       Date:  2012-12-04       Impact factor: 1.568

3.  Effects of Scleral Contact Lenses for Keratoconus Management on Visual Quality and Intraocular Pressure.

Authors:  Martina Formisano; Federica Franzone; Ludovico Alisi; Santino Pistella; Leopoldo Spadea
Journal:  Ther Clin Risk Manag       Date:  2021-01-25       Impact factor: 2.423

4.  The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.

Authors:  Fabrizio Zeri; Mario De Cusatis; Luigi Lupelli; Peter Graham Swann
Journal:  J Optom       Date:  2015-10-21

5.  Comparison of Pneumatonometry and Transpalpebral Tonometry Measurements of Intraocular Pressure during Scleral Lens Wear.

Authors:  Jennifer Swingle Fogt; Cherie B Nau; Muriel Schornack; Ellen Shorter; Amy Nau; Jennifer S Harthan
Journal:  Optom Vis Sci       Date:  2020-09       Impact factor: 2.106

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.