Intraocular Pressure After 2 Hours of Small-Diameter Scleral Lens Wear.

Cherie B Nau1, Muriel M Schornack, Jay W McLaren, Arthur J Sit.   

Abstract

OBJECTIVES: Compression of episcleral veins or deformation of tissue in the Schlemm's canal beneath the landing zone of scleral lenses could elevate intraocular pressure (IOP). We examined the effect of 2 hr of small-diameter scleral lens wear on IOP.
METHODS: Twenty-nine participants, 29 ± 6 years old (mean ± SD) who experienced no history of eye disease or scleral lens wear, were included in the study. Each participant was fitted with a 15-mm Jupiter scleral lens on one eye (study eye). Intraocular pressure was measured in both eyes by pneumatonometry centrally on the cornea and peripherally on the sclera. The lens was then placed on one eye and was worn for 2 hr. Intraocular pressure was remeasured immediately after lens placement, at 1 and 2 hr of lens wear, and immediately after lens removal. Intraocular pressure after removal of the scleral lens was compared with IOP before placing the lens and to IOP in the control eye using paired t tests.
RESULTS: Immediately after removing the scleral lens, mean central IOP in the study eye (13.9 ± 3.1 mm Hg) was not different from mean central IOP in the control eye (13.5 ± 2.2 mm Hg, P = 0.4) or in the same eye before lens wear (13.6 ± 1.9 mm Hg, P = 0.6). There were also no differences in IOP measured peripherally at 2 hr of lens wear (P = 0.8).
CONCLUSIONS: Neophyte scleral lens wear of a 15-mm scleral lens for 2 hr does not increase IOP in healthy eyes.

Entities:  

Mesh:

Year:  2016        PMID: 26629960      PMCID: PMC4887421          DOI: 10.1097/ICL.0000000000000214

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  15 in total

1.  Conjunctival thickness measured by optical coherence tomography.

Authors:  Xing-Ru Zhang; Zhen-Yong Zhang; Matthew R Hoffman
Journal:  Ophthalmology       Date:  2013-06       Impact factor: 12.079

2.  Intraocular pressure measurement with the Tono-Pen through soft contact lenses.

Authors:  W C Panek; W A Boothe; D A Lee; E Zemplenyi; T H Pettit
Journal:  Am J Ophthalmol       Date:  1990-01-15       Impact factor: 5.258

3.  The effect of hydrogel and silicone hydrogel contact lenses on the measurement of intraocular pressure with rebound tonometry.

Authors:  Fabrizio Zeri; Paolo Calcatelli; Bernardo Donini; Luigi Lupelli; Luciana Zarrilli; Peter G Swann
Journal:  Cont Lens Anterior Eye       Date:  2011-06-01       Impact factor: 3.077

4.  Intraocular pressure measurement with the noncontact tonometer through soft contact lenses.

Authors:  Yi-Chun Liu; Jehn-Yu Huang; I-Jong Wang; Fung-Rong Hu; Yu-Chih Hou
Journal:  J Glaucoma       Date:  2011-03       Impact factor: 2.503

5.  The effects of therapeutic contact lenses on intraocular pressure measurement.

Authors:  G D Scibilia; W H Ehlers; P C Donshik
Journal:  CLAO J       Date:  1996-10

6.  Accurate intraocular pressure measurement in contact lens wearers with normal pressures.

Authors:  L Lim; T P Ng; D T Tan
Journal:  CLAO J       Date:  1997-04

Review 7.  Aqueous humor outflow: dynamics and disease.

Authors:  Uttio Roy Chowdhury; Cheryl R Hann; W Daniel Stamer; Michael P Fautsch
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

8.  The effect of age and conjunctivochalasis on conjunctival thickness.

Authors:  Xing-Ru Zhang; Zhen-Yong Zhang; Matthew R Hoffman; Qing-Song Li; Bin Liu; Huan-Ming Zhou
Journal:  Curr Eye Res       Date:  2012-12-18       Impact factor: 2.424

9.  A comparison of the short-term settling of three scleral lens designs.

Authors:  Matthew J Kauffman; Christopher A Gilmartin; Edward S Bennett; Carl J Bassi
Journal:  Optom Vis Sci       Date:  2014-12       Impact factor: 1.973

10.  Influence of lens material and intra-ocular pressure on the outcome of non-contact tonometry over soft contact lenses.

Authors:  Sudi Patel; Graeme Stevenson
Journal:  Cont Lens Anterior Eye       Date:  2009-02-04       Impact factor: 3.077

View more
  4 in total

1.  Glaucoma Prevalence and Glaucoma Surgical Considerations in Prosthetic Replacement of the Ocular Surface Ecosystem Device Use.

Authors:  Andrew T Duong; Monica K Ertel; Sarah H Van Tassel
Journal:  Eye Contact Lens       Date:  2022-02-01       Impact factor: 2.018

2.  Effects of Scleral Contact Lenses for Keratoconus Management on Visual Quality and Intraocular Pressure.

Authors:  Martina Formisano; Federica Franzone; Ludovico Alisi; Santino Pistella; Leopoldo Spadea
Journal:  Ther Clin Risk Manag       Date:  2021-01-25       Impact factor: 2.423

3.  Scleral Tonometry Precision During Scleral Lens Wear: A Pilot Study.

Authors:  Allen Y Ganjei; Gabriel G L Shlager; Daniel Brocks
Journal:  Clin Optom (Auckl)       Date:  2021-12-31

4.  Comparison of Pneumatonometry and Transpalpebral Tonometry Measurements of Intraocular Pressure during Scleral Lens Wear.

Authors:  Jennifer Swingle Fogt; Cherie B Nau; Muriel Schornack; Ellen Shorter; Amy Nau; Jennifer S Harthan
Journal:  Optom Vis Sci       Date:  2020-09       Impact factor: 2.106

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.