Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.

Jeroen Van Dessel, Laura Ferreira Pinheiro Nicolielo, Yan Huang, Pieter Slagmolen, Constantinus Politis, Ivo Lambrichts, Reinhilde Jacobs.   

Abstract

PURPOSE: To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement.
MATERIALS AND METHODS: Eight edentulous human mandibular bone samples were scanned with seven CBCT scanners (3D Accuitomo 170, i-CAT Next Generation, ProMax 3D Max, Scanora 3D, Cranex 3D, Newtom GiANO and Carestream 9300) and one MSCT system (Somatom Definition Flash) using the clinical exposure protocol with the highest resolution. Micro-CT (SkyScan 1174) images served as a gold standard. A volume of interest (VOI) comprising trabecular and cortical bone only was delineated on the micro-CT. After spatial alignment of all scan types, micro-CT VOIs were overlaid on the CBCT and MSCT images. Segmentation was applied and morphometric parameters were calculated for each scanner. CBCT and MSCT morphometric parameters were compared with micro-CT using mixed-effect models. Intraclass correlation analysis was used to grade the accuracy of each scanner in assessing trabecular and cortical quality in comparison with the gold standard. Bone structure patterns of each scanner were compared with micro-CT in 2D and 3D to facilitate the interpretation of the morphometric analysis.
RESULTS: Morphometric analysis showed an overestimation of the cortical and trabecular bone quantity during CBCT and MSCT evaluation compared to the gold standard micro-CT. The trabecular thickness (Tb.Th) was found to be significantly (P < 0.05) different and the smallest overestimation was found for the ProMax 3D Max (180 µm), followed by the 3D Accuitomo 170 (200 µm), Carestream 9300 (220 µm), Newtom GiANO (240 µm), Cranex 3D (280 µm), Scanora 3D (300 µm), high resolution MSCT (310 µm), i-CAT Next Generation (430 µm) and standard resolution MSCT (510 µm). The underestimation of the cortical thickness (Ct.Th) in ProMax 3D Max (-10 µm), the overestimation in Newtom GiANO (10 µm) and the high resolution MSCT (10 µm) were neglible. However, a significant overestimation (P < 0.05) was found for 3D Accuitomo 170 (110 µm), Scanora 3D (140 µm), standard resolution MSCT (150 µm), Carestream 9300 (190 µm), Cranex 3D (190 µm) and i-CAT Next Generation (230 µm). Comparison of the 2D network and 3D surface distance confirmed the overestimation in bone quantity, but only demonstrated a deviant trabecular network for the i-CAT Next Generation and the standard resolution MSCT. Intraclass correlation coefficients (ICCs) showed a significant (P < 0.05) high intra-observer reliability (ICC > 0.70) in morphometric evaluation between micro-CT and commercially available CBCT scanners (3D Accuitomo 170, Newtom GiANO and ProMax 3D Max). The ICC for Tb.Th and Ct.Th were 0.72 and 0.98 (3D Accuitomo 170), 0.71 and 0.96 (Newtom GiANO), and 0.87 and 0.92 (ProMax 3D Max), respectively.
CONCLUSIONS: High resolution CBCT offers a clinical alternative to MSCT to objectively determine the bone quality prior to implant placement. However, not all tested CBCT machines have sufficient resolution to accurately depict the trabecular network or cortical bone. Conflict-of-interest statement: There is no conflict of interest to declare. FUNDING: Fellowship support came from Research Foundation Flanders (FWO) from the Belgian government, and Coordination for the Improvement of Higher Education Personnel (CAPES) program and Science without borders from the Brazilian government.

Entities:  

Mesh:

Year:  2016        PMID: 27990508

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  13 in total

1.  Computer-based automatic classification of trabecular bone pattern can assist radiographic bone quality assessment at dental implant site.

Authors:  Laura Ferreira Pinheiro Nicolielo; Jeroen Van Dessel; G Harry van Lenthe; Ivo Lambrichts; Reinhilde Jacobs
Journal:  Br J Radiol       Date:  2018-09-17       Impact factor: 3.039

2.  3D quantification of in vivo orthodontic tooth movement in rats by means of micro-computed tomography.

Authors:  Maria Cadenas de Llano-Pérula; Chen Zong; Jeroen Van Dessel; Anne Marie Kuijpers-Jagtman; Guy Willems
Journal:  Clin Oral Investig       Date:  2022-01-07       Impact factor: 3.573

3.  Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT.

Authors:  Norliza Ibrahim; Azin Parsa; Bassam Hassan; Paul van der Stelt; Rabiah A Rahmat; Siti M Ismail; Irene H A Aartman
Journal:  BMC Oral Health       Date:  2021-05-08       Impact factor: 2.757

4.  Qualitative assesement of newly formed bone after distraction osteogenesis of mandible in patients with facial asymmetry using 3 dimensional computed tomography.

Authors:  Abhay Datarkar; Bhavana Valvi; Suraj Parmar; Jagadish Patil
Journal:  J Oral Biol Craniofac Res       Date:  2021-03-26

5.  Validation of a novel imaging approach using multi-slice CT and cone-beam CT to follow-up on condylar remodeling after bimaxillary surgery.

Authors:  Laura Ferreira Pinheiro Nicolielo; Jeroen Van Dessel; Eman Shaheen; Carolina Letelier; Marina Codari; Constantinus Politis; Ivo Lambrichts; Reinhilde Jacobs
Journal:  Int J Oral Sci       Date:  2017-07-14       Impact factor: 6.344

6.  Feasibility of micro-computed tomography to detect and classify proximal caries lesions in vitro.

Authors:  Karla Rovaris; Liana Matos Ferreira; Thiago Oliveira Sousa; Leonardo Vieira Peroni; Deborah Queiroz Freitas; Ann Wenzel; Francisco Haiter-Neto
Journal:  Dent Res J (Isfahan)       Date:  2018 Mar-Apr

7.  Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography.

Authors:  Rong-Ting He; Ming-Gene Tu; Heng-Li Huang; Ming-Tzu Tsai; Jay Wu; Jui-Ting Hsu
Journal:  BMC Med Imaging       Date:  2019-01-23       Impact factor: 1.930

8.  Osteonecrosis of the Jaw Beyond Bisphosphonates: Are There Any Unknown Local Risk Factors?

Authors:  Johann Lechner; Volker von Baehr; Bernd Zimmermann
Journal:  Clin Cosmet Investig Dent       Date:  2021-01-19

9.  Evaluation of metal artefacts for two CBCT devices with a new dental arch phantom.

Authors:  Luciano Augusto Cano Martins; Polyane Mazucatto Queiroz; Yuri Nejaim; Karla de Faria Vasconcelos; Francisco Carlos Groppo; Francisco Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2020-03-16       Impact factor: 2.419

10.  Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri-implant bone defects.

Authors:  Dandan Song; Sohaib Shujaat; Karla de Faria Vasconcelos; Yan Huang; Constantinus Politis; Ivo Lambrichts; Reinhilde Jacobs
Journal:  BMC Med Imaging       Date:  2021-02-10       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.