Literature DB >> 33568085

Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri-implant bone defects.

Dandan Song1, Sohaib Shujaat2, Karla de Faria Vasconcelos2, Yan Huang2,3, Constantinus Politis2, Ivo Lambrichts4, Reinhilde Jacobs2,5.   

Abstract

BACKGROUND: Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification, and measurement of peri-implant bone defects in an animal model.
METHODS: Fifty-four mandible blocks with implants were harvested from nine male health adult beagle dogs with acquisition of IO, CBCT and micro-CT images from all samples. Peri-implant bone defects from 16 samples were diagnosed using micro-CT and classified into 3 defect categories: dehiscence (n = 5), infrabony defect (n = 3) and crater-like defect (n = 8). Following training and calibration of the observers, they asked to detect location (mesial, distal, buccal, lingual) and shape of the defect (dehiscence, horizontal defect, vertical defect, carter-like defect) utilizing both IO and CBCT images. Both observers assessed defect depth and width on IO, CBCT and micro-CT images at each side of peri-implant bone defect via CT-analyzer software. Data were analyzed using SPSS software and a p value of < 0.05 was considered as statistically significant.
RESULTS: Overall, there was a high diagnostic accuracy for detection of bone defects with CBCT images (sensitivity: 100%/100%), while IO images showed a reduction in accuracy (sensitivity: 69%/63%). Similarly, diagnostic accuracy for defect classification was significantly higher for CBCT, whereas IO images were unable to correctly identify vestibular dehiscence, with incorrect assessment of half of the infrabony defects. For accuracy of measuring defect depth and width, a higher correlation was observed between CBCT and gold standard micro-CT (r = 0.91, 95% CI 0.86-0.94), whereas a lower correlation was seen for IO images (r = 0.82, 95% CI 0.67-0.91).
CONCLUSIONS: The diagnostic accuracy and reliability of CBCT was found to be superior to IO imaging for the detection, classification, and measurement of peri-implant bone defects. The application of CBCT adds substantial information related to the peri-implant bone defect diagnosis and decision-making which cannot be achieved with conventional IO imaging.

Entities:  

Keywords:  Alveolar bone loss; CBCT; Dental radiography; Peri‐implantitis

Mesh:

Substances:

Year:  2021        PMID: 33568085      PMCID: PMC7877020          DOI: 10.1186/s12880-021-00557-9

Source DB:  PubMed          Journal:  BMC Med Imaging        ISSN: 1471-2342            Impact factor:   1.930


  45 in total

Review 1.  Diagnosis and epidemiology of periodontal osseous lesions.

Authors:  P N Papapanou; M S Tonetti
Journal:  Periodontol 2000       Date:  2000-02       Impact factor: 7.589

2.  Radiographic detection and assessment of the periodontal endosseous defects.

Authors:  E A Pepelassi; K Tsiklakis; A Diamanti-Kipioti
Journal:  J Clin Periodontol       Date:  2000-04       Impact factor: 8.728

3.  Accuracy of radiographic assessment of interproximal bone loss in intrabony defects using linear measurements.

Authors:  P Eickholz; E Hausmann
Journal:  Eur J Oral Sci       Date:  2000-02       Impact factor: 2.612

4.  Evaluation of high-resolution cone beam computed tomography in the detection of simulated interradicular bone lesions.

Authors:  M Noujeim; Tj Prihoda; R Langlais; P Nummikoski
Journal:  Dentomaxillofac Radiol       Date:  2009-03       Impact factor: 2.419

Review 5.  Radiographic diagnosis in periodontics.

Authors:  M K Jeffcoat; I C Wang; M S Reddy
Journal:  Periodontol 2000       Date:  1995-02       Impact factor: 7.589

6.  A controlled study on the accuracy and precision of intraoral radiography in assessing interproximal bone defect morphology around teeth and implants.

Authors:  Véronique Christiaens; Hugo De Bruyn; Hilde De Vree; Sabine Lamoral; Reinhilde Jacobs; Jan Cosyn
Journal:  Eur J Oral Implantol       Date:  2018       Impact factor: 3.123

7.  Detection of simulated periodontal defects using cone-beam CT and digital intraoral radiography.

Authors:  Samaneh Bayat; Ahmad Reza Talaeipour; Fatemeh Sarlati
Journal:  Dentomaxillofac Radiol       Date:  2016-05-18       Impact factor: 2.419

8.  Correlation of Three-Dimensional Radiologic Data with Subsequent Treatment Approach in Patients with Peri-implantitis: A Retrospective Analysis.

Authors:  Philip Bender; Giovanni E Salvi; Daniel Buser; Anton Sculean; Michael M Bornstein
Journal:  Int J Periodontics Restorative Dent       Date:  2017 Jul/Aug       Impact factor: 1.840

Review 9.  Are peri-implantitis lesions different from periodontitis lesions?

Authors:  Tord Berglundh; Nicola U Zitzmann; Mauro Donati
Journal:  J Clin Periodontol       Date:  2011-03       Impact factor: 8.728

10.  Influence of bony defects on implant stability.

Authors:  Joe Merheb; Wim Coucke; Reinhilde Jacobs; Ignace Naert; Marc Quirynen
Journal:  Clin Oral Implants Res       Date:  2010-05-09       Impact factor: 5.977

View more
  5 in total

Review 1.  Assessment of the prevalence and length of the anterior and caudal loops of the mental nerve as anatomical variants of exiting the mandible at the mental foramen using cone-beam computed tomography: a systematic review and meta-analysis.

Authors:  Liuling Hui; Kuo Feng Hung; Michael Marc Bornstein; Yiu Yan Leung
Journal:  Clin Oral Investig       Date:  2022-08-09       Impact factor: 3.606

2.  Mesiodistal Measurements for Dental Implant Planning: A Prospective Clinical Study of Linear Measurements on Cone-Beam Computed Tomography Images in Comparison with Caliper-Based Measurements on Plaster Casts.

Authors:  Lydia Vazquez; Ramona Buser; Jean-Pierre Carrel
Journal:  Dent J (Basel)       Date:  2022-09-07

3.  Accuracy of bone-level assessments following reconstructive surgical treatment of experimental peri-implantitis.

Authors:  Ahmed Almohandes; Henrik Lund; Olivier Carcuac; Max Petzold; Tord Berglundh; Ingemar Abrahamsson
Journal:  Clin Oral Implants Res       Date:  2022-02-16       Impact factor: 5.021

4.  Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study.

Authors:  Paweł Sawicki; Piotr Regulski; Artur Winiarski; Paweł J Zawadzki
Journal:  J Clin Med       Date:  2022-07-02       Impact factor: 4.964

5.  Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants.

Authors:  Rocharles Cavalcante Fontenele; Eduarda Helena Leandro Nascimento; Ana Catarina Imbelloni-Vasconcelos; Luciano Augusto Cano Martins; Andrea Dos Anjos Pontual; Flávia Maria Moraes Ramos-Perez; Deborah Queiroz Freitas
Journal:  Imaging Sci Dent       Date:  2022-07-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.