Literature DB >> 27951427

Anisotropic phantom to calibrate high-q diffusion MRI methods.

M E Komlosh1, D Benjamini2, A S Barnett2, V Schram3, F Horkay2, A V Avram2, P J Basser2.   

Abstract

A silicon oil-filled glass capillary array is proposed as an anisotropic diffusion MRI phantom. Together with a computational/theoretical pipeline these provide a gold standard for calibrating and validating high-q diffusion MRI experiments. The phantom was used to test high angular resolution diffusion imaging (HARDI) and double pulsed-field gradient (d-PFG) MRI acquisition schemes. MRI-based predictions of microcapillary diameter using both acquisition schemes were compared with results from optical microscopy. This phantom design can be used for quality control and quality assurance purposes and for testing and validating proposed microstructure imaging experiments and the processing pipelines used to analyze them.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Anisotropic diffusion; DDE; Diffusion; MRI; Microstructure; Phantom; d-PFG

Mesh:

Year:  2016        PMID: 27951427      PMCID: PMC5325680          DOI: 10.1016/j.jmr.2016.11.017

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  41 in total

1.  High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity.

Authors:  David S Tuch; Timothy G Reese; Mette R Wiegell; Nikos Makris; John W Belliveau; Van J Wedeen
Journal:  Magn Reson Med       Date:  2002-10       Impact factor: 4.668

2.  Diffusion tensor MR imaging of the human brain.

Authors:  C Pierpaoli; P Jezzard; P J Basser; A Barnett; G Di Chiro
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

3.  Validation of q-ball imaging with a diffusion fibre-crossing phantom on a clinical scanner.

Authors:  Muriel Perrin; Cyril Poupon; Bernard Rieul; Patrick Leroux; André Constantinesco; Jean-François Mangin; Denis Lebihan
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2005-05-29       Impact factor: 6.237

4.  Use of capillaries in the construction of an MRI phantom for the assessment of diffusion tensor imaging: demonstration of performance.

Authors:  Nathan Yanasak; Jerry Allison
Journal:  Magn Reson Imaging       Date:  2006-10-05       Impact factor: 2.546

5.  A general framework to quantify the effect of restricted diffusion on the NMR signal with applications to double pulsed field gradient NMR experiments.

Authors:  Evren Ozarslan; Noam Shemesh; Peter J Basser
Journal:  J Chem Phys       Date:  2009-03-14       Impact factor: 3.488

6.  Detection of microscopic anisotropy in gray matter and in a novel tissue phantom using double Pulsed Gradient Spin Echo MR.

Authors:  M E Komlosh; F Horkay; R Z Freidlin; U Nevo; Y Assaf; P J Basser
Journal:  J Magn Reson       Date:  2007-07-18       Impact factor: 2.229

7.  Diffusion coefficient measurement using a temperature-controlled fluid for quality control in multicenter studies.

Authors:  Thomas L Chenevert; Craig J Galbán; Marko K Ivancevic; Susan E Rohrer; Frank J Londy; Thomas C Kwee; Charles R Meyer; Timothy D Johnson; Alnawaz Rehemtulla; Brian D Ross
Journal:  J Magn Reson Imaging       Date:  2011-10       Impact factor: 4.813

8.  Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom.

Authors:  Michal E Komlosh; Evren Özarslan; Martin J Lizak; Ferenc Horkay; Vincent Schram; Noam Shemesh; Yoram Cohen; Peter J Basser
Journal:  J Magn Reson       Date:  2010-10-26       Impact factor: 2.229

9.  New diffusion phantoms dedicated to the study and validation of high-angular-resolution diffusion imaging (HARDI) models.

Authors:  Cyril Poupon; Bernard Rieul; Irina Kezele; Muriel Perrin; Fabrice Poupon; Jean-François Mangin
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

10.  Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo.

Authors:  P S Tofts; D Lloyd; C A Clark; G J Barker; G J Parker; P McConville; C Baldock; J M Pope
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

View more
  5 in total

Review 1.  Physical and numerical phantoms for the validation of brain microstructural MRI: A cookbook.

Authors:  Els Fieremans; Hong-Hsi Lee
Journal:  Neuroimage       Date:  2018-06-18       Impact factor: 6.556

2.  Design and validation of diffusion MRI models of white matter.

Authors:  Ileana O Jelescu; Matthew D Budde
Journal:  Front Phys       Date:  2017-11-28

3.  Validation of diffusion MRI estimates of compartment size and volume fraction in a biomimetic brain phantom using a human MRI scanner with 300 mT/m maximum gradient strength.

Authors:  Qiuyun Fan; Aapo Nummenmaa; Barbara Wichtmann; Thomas Witzel; Choukri Mekkaoui; Walter Schneider; Lawrence L Wald; Susie Y Huang
Journal:  Neuroimage       Date:  2018-01-12       Impact factor: 6.556

4.  Generalized Mean Apparent Propagator MRI to Measure and Image Advective and Dispersive Flows in Medicine and Biology.

Authors:  Dan Benjamini; Michal E Komlosh; Nathan H Williamson; Peter J Basser
Journal:  IEEE Trans Med Imaging       Date:  2018-07-12       Impact factor: 10.048

5.  Temperature and concentration calibration of aqueous polyvinylpyrrolidone (PVP) solutions for isotropic diffusion MRI phantoms.

Authors:  Friedrich Wagner; Frederik B Laun; Tristan A Kuder; Anna Mlynarska; Florian Maier; Jonas Faust; Kerstin Demberg; Linus Lindemann; Boris Rivkin; Armin M Nagel; Mark E Ladd; Klaus Maier-Hein; Sebastian Bickelhaupt; Michael Bach
Journal:  PLoS One       Date:  2017-06-19       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.