Two-phase in vitro testing was performed to determine the initial mechanical stability of uncemented but fixed porous coated acetabular components. Six each of three-screw fixation, two-peg fixation, and three-spike fixation porous acetabular components were implanted into fresh and embalmed human cadaver acetabula. Measurement of prosthesis-bone displacement at a load of 100 kg did not show a significant difference among the three methods of fixation. However, torque testing showed that three-screw fixation failed at significantly higher loads (46 N-m) than two-peg fixation (32 N-m) or three-spike fixation (32 N-m).

Entities:  

Mesh:

Year:  1989        PMID: 2795026     DOI: 10.1016/s0883-5403(89)80015-4

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

2.  Metropolitan and micropolitan statistical area estimates of depression and anxiety using the Patient Health Questionnaire-8 in the 2006 Behavioral Risk Factor Surveillance System.

Authors:  Tara W Strine; Satvinder S Dhingra; Kurt Kroenke; Mohamed Qayad; James L Ribble; Catherine A Okoro; Lina S Balluz; Shanta R Dube; James Lando; Ali H Mokdad
Journal:  Int J Public Health       Date:  2009       Impact factor: 3.380

3.  Press-fit cementless acetabular fixation with and without screws.

Authors:  Sheng-Hui Ni; Lei Guo; Tian-Long Jiang; Jie Zhao; Yan-Gang Zhao
Journal:  Int Orthop       Date:  2013-08-28       Impact factor: 3.075

4.  [Reconstruction of large acetabular defects using trabecular metal augments].

Authors:  Olaf Hasart; Carsten Perka; Rex Lehnigk; Stephan Tohtz
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

5.  Protrusio After Medial Acetabular Wall Breach in Total Hip Arthroplasty.

Authors:  Christopher T Martin; Anneliese D Heiner; Thomas E Baer; Andrew J Pugely; Nicolas O Noiseux
Journal:  Iowa Orthop J       Date:  2015

6.  The optimal screw-hole positions of the eccentric revision cup based on a morphological study.

Authors:  Yanchao Zhang; Haiyang Ma; Yang Liu; Junmin Shen; Bohan Zhang; Yonggang Zhou
Journal:  J Orthop Surg Res       Date:  2022-08-12       Impact factor: 2.677

7.  Comparison of the plantar pressure distributions at different degrees of tilting: a preliminary report.

Authors:  Sung-Min Son; Jun-Ho Lee; Yong-Jun Cha
Journal:  J Phys Ther Sci       Date:  2014-03-25

8.  Acetabular components with or without screws in total hip arthroplasty.

Authors:  Murad Pepe; Onur Kocadal; Tamer Erener; Kubilay Ceritoglu; Ertugrul Aksahin; Cem Nuri Aktekin
Journal:  World J Orthop       Date:  2017-09-18

9.  Management of intraoperative acetabular fracture in primary total hip arthroplasty.

Authors:  Juncheng Li; Quanbo Ji; Ming Ni; Qingyuan Zheng; Jingyang Sun; Guoqiang Zhang
Journal:  BMC Musculoskelet Disord       Date:  2020-06-15       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.