Catheter Ablation for Atrial Fibrillation in Patients With Watchman Left Atrial Appendage Occlusion Device: Results from a Multicenter Registry.

Mohit K Turagam1, Madhav Lavu2, Muhammad R Afzal2, Venkat Vuddanda2, Mohammad-Ali Jazayeri2, Valay Parikh1, Donita Atkins2, Sudharani Bommana2, Luigi DI Biase3, Rodney Horton4, Rong Bai5, Vijay Swarup6, Jie Cheng7, Andrea Natale4, Dhanunjaya Lakkireddy2.   

Abstract

BACKGROUND: There have been an increasing number of atrial fibrillation (AF) patients with Watchman left atrial appendage occlusion (LAAO) device, requiring catheter ablation (CA) for maintenance of normal sinus rhythm. In this study, we describe our experience with the feasibility and safety of CA in patients with a preexisting Watchman LAAO device.
METHODS: This was a retrospective multicenter AF registry of 60 patients with Watchman LAAO device who underwent CA for AF. Baseline clinical and procedural characteristics of the included subjects were retrieved from review of medical records and were analyzed.
RESULTS: The mean age was 72.7 ± 4.9 years and the mean CHADS2 score was 2.3 ± 0.6. All patients had successful pulmonary vein isolation (PVI). The left atrial appendage (LAA) was electrically active in 34 (56%) while reentrant tachycardia and AF triggers were seen in 17 (28%) patients. Electrical isolation was attempted in these 17 patients with only 10 achieving complete LAA isolation. Repeat imaging showed new peri-device leaks in 30% (12/40) patients, while new significant peri-device leaks (≥5 mm) were noted in 10% (10/40) of patients after RFA, respectively, requiring continuation of oral anticoagulation. There were a higher proportion of patients with severe peri-device leaks (≥5 mm) after LAA isolation. However, >50% of those leaks sealed off on follow-up transesophageal echocardiogram.
CONCLUSION: AF ablation is a feasible and safe in patients with preexisting Watchman LAAO device. Electrical isolation of the LAA could be difficult and when attempted can result in increased risk of short-term peri-device leak and recurrence of AT/AF in almost all patients.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  Watchman device; atrial fibrillation; catheter ablation; left atrial appendage exclusion; left atrial appendage triggers; pulmonary vein isolation

Mesh:

Year:  2017        PMID: 27943538     DOI: 10.1111/jce.13148

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  8 in total

Review 1.  [Electrical isolation of the left atrial appendage : Benefits and risks].

Authors:  B Bellmann; R R Tilz; A Rillig
Journal:  Herz       Date:  2017-06       Impact factor: 1.443

2.  Bailout left atrial appendage occluder for pulmonary vein isolation and electrical cardioversion in patients with atrial fibrillation and left atrial appendage thrombus: a pilot study.

Authors:  Chin-Feng Tsai; Pang-Shuo Huang; Fu-Chun Chiu; Jien-Jiun Chen; Sheng-Nan Chang; Jung-Cheng Hsu; Su-Kiat Chua; Hsiao-Liang Cheng; Yi-Chih Wang; Juey-Jen Hwang; Chia-Ti Tsai
Journal:  Clin Res Cardiol       Date:  2022-09-02       Impact factor: 6.138

3.  Periprocedural Outcomes Associated With Use of a Left Atrial Appendage Occlusion Device in China.

Authors:  Fangju Su; Chao Gao; Jianzheng Liu; Zhongping Ning; Beng He; Yi Liu; Yawei Xu; Bing Yang; Yuechun Li; Junfeng Zhang; Xianxian Zhao; Yushun Zhang; Hao Hu; Xianfeng Du; Ruiqin Xie; Ling Zhou; Jie Zeng; Zhongbao Ruan; Haitao Liu; Jun Guo; Rutao Wang; Scot Garg; Osama Soliman; David R Holmes; Patrick W Serruys; Ling Tao
Journal:  JAMA Netw Open       Date:  2022-05-02

4.  Safety and Efficacy of Left Atrial Catheter Ablation in Patients with Left Atrial Appendage Occlusion Devices.

Authors:  Binhao Wang; Bin He; Guohua Fu; Mingjun Feng; Xianfeng Du; Jing Liu; Yibo Yu; Huimin Chu
Journal:  J Clin Med       Date:  2022-05-31       Impact factor: 4.964

Review 5.  Left Atrial Appendage Closure and Pulmonary Vein Isolation.

Authors:  Payam Safavi-Naeini; Abdi Rasekh
Journal:  Tex Heart Inst J       Date:  2020-02-01

6.  Cryoballoon Ablation of the Pulmonary Veins, the Posterior Wall, the Left Atrial Appendage, and the Mitral Isthmus Guided by Intracardiac Echocardiography-integrated and Three-dimensional Mapping.

Authors:  Arash Aryana; Paula Lafortune; Luigi Di Biase; Andrea Natale
Journal:  J Innov Card Rhythm Manag       Date:  2022-01-15

7.  Cryoballoon pulmonary vein isolation and voltage mapping for symptomatic atrial fibrillation 9 months after Watchman device implantation.

Authors:  Henry D Huang; Viren M Patel; Parikshit S Sharma; Zenith Jameria; Sorin Lazar; Richard Trohman; Erik Wissner
Journal:  HeartRhythm Case Rep       Date:  2017-10-25

Review 8.  Combination of ablation and left atrial appendage closure as "One-stop" procedure in the treatment of atrial fibrillation: Current status and future perspective.

Authors:  Ben He; Li-Sheng Jiang; Zi-Yong Hao; Hao Wang; Yu-Tong Miao
Journal:  Pacing Clin Electrophysiol       Date:  2021-03-09       Impact factor: 1.976

  8 in total