Literature DB >> 28357448

[Electrical isolation of the left atrial appendage : Benefits and risks].

B Bellmann1, R R Tilz2, A Rillig3.   

Abstract

The left atrial appendage (LAA) is an extension originating from the body of the left atrium. The LAA is derived from the primary atrium and shows anatomical and physiological deviations from the left atrium. Different LAA morphologies exist. The LAA is not only the most frequent origin of intracardiac thrombi, it also frequently shows triggers responsible for the initiation or maintenance of atrial tachyarrhythmia and atrial fibrillation (AF). Isolation of the LAA using radiofrequency energy in addition to isolation of the pulmonary vein has recently gained importance due to the potential for increasing the clinical success rates, particularly in patients with persistent and long-standing persistent AF; however, after LAA isolation the incidence of LAA thrombi and systemic thromboembolisms might be increased even under treatment with oral anticoagulants, depending on the ablation strategy used. Thus, mechanical occlusion of the LAA should be discussed with patients after electrical isolation of the LAA.

Entities:  

Keywords:  Atrial fibrillation; Left atrial appendage isolation; Left atrial appendage occlusion; Stroke; Thromboembolism

Mesh:

Substances:

Year:  2017        PMID: 28357448     DOI: 10.1007/s00059-017-4559-0

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  44 in total

1.  Left atrial catheter ablation subsequent to Watchman® left atrial appendage device implantation: a single centre experience.

Authors:  Daniel T Walker; Karen P Phillips
Journal:  Europace       Date:  2015-05-21       Impact factor: 5.214

2.  Anatomic analysis of the left atrial appendage after closure with the LARIAT device.

Authors:  Krzysztof Bartus; Remo L Morelli; Wojciech Szczepanski; Boguslaw Kapelak; Jerzy Sadowski; Randall J Lee
Journal:  Circ Arrhythm Electrophysiol       Date:  2014-08

3.  Localized reentry within the left atrial appendage: arrhythmogenic role in patients undergoing ablation of persistent atrial fibrillation.

Authors:  Mélèze Hocini; Ashok J Shah; Isabelle Nault; Prashanthan Sanders; Matthew Wright; Sanjiv M Narayan; Yoshihide Takahashi; Pierre Jaïs; Seiichiro Matsuo; Sébastien Knecht; Frédéric Sacher; Kang-Teng Lim; Jacques Clémenty; Michel Haïssaguerre
Journal:  Heart Rhythm       Date:  2011-07-12       Impact factor: 6.343

4.  Unexpectedly High Incidence of Stroke and Left Atrial Appendage Thrombus Formation After Electrical Isolation of the Left Atrial Appendage for the Treatment of Atrial Tachyarrhythmias.

Authors:  Andreas Rillig; Roland R Tilz; Tina Lin; Thomas Fink; Christian-H Heeger; Anita Arya; Andreas Metzner; Shibu Mathew; Erik Wissner; Hisaki Makimoto; Peter Wohlmuth; Karl-Heinz Kuck; Feifan Ouyang
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-05

5.  Left atrial appendage: an underrecognized trigger site of atrial fibrillation.

Authors:  Luigi Di Biase; J David Burkhardt; Prasant Mohanty; Javier Sanchez; Sanghamitra Mohanty; Rodney Horton; G Joseph Gallinghouse; Shane M Bailey; Jason D Zagrodzky; Pasquale Santangeli; Steven Hao; Richard Hongo; Salwa Beheiry; Sakis Themistoclakis; Aldo Bonso; Antonio Rossillo; Andrea Corrado; Antonio Raviele; Amin Al-Ahmad; Paul Wang; Jennifer E Cummings; Robert A Schweikert; Gemma Pelargonio; Antonio Dello Russo; Michela Casella; Pietro Santarelli; William R Lewis; Andrea Natale
Journal:  Circulation       Date:  2010-07-06       Impact factor: 29.690

6.  Experience matters: long-term results of pulmonary vein isolation using a robotic navigation system for the treatment of paroxysmal atrial fibrillation.

Authors:  Andreas Rillig; Tina Lin; Boris Schmidt; Britta Feige; Christian Heeger; Jascha Wegner; Erik Wissner; Andreas Metzner; Anita Arya; Shibu Mathew; Peter Wohlmuth; Feifan Ouyang; Karl-Heinz Kuck; Roland Richard Tilz
Journal:  Clin Res Cardiol       Date:  2015-07-22       Impact factor: 5.460

7.  Left atrial appendage ligation with the next generation LARIAT(+) suture delivery device: Early clinical experience.

Authors:  Krzysztof Bartus; Sameer Gafoor; David Tschopp; John P Foran; Roland Tilz; Tom Wong; Dhanunjaya Lakkireddy; Horst Sievert; Randall J Lee
Journal:  Int J Cardiol       Date:  2016-04-06       Impact factor: 4.164

8.  Rationale and design of the Left Atrial Appendage Occlusion Study (LAAOS) III.

Authors:  Richard Whitlock; Jeff Healey; Jessica Vincent; Kate Brady; Kevin Teoh; Alistair Royse; Pallav Shah; Yingqiang Guo; Marco Alings; Richard J Folkeringa; Domenico Paparella; Andrea Colli; Steven R Meyer; Jean-François Legare; François Lamontagne; Wilko Reents; Andreas Böning; Stuart Connolly
Journal:  Ann Cardiothorac Surg       Date:  2014-01

9.  Left atrial isthmus line ablation using a remote robotic navigation system: feasibility, efficacy and long-term outcome.

Authors:  Andreas Rillig; Boris Schmidt; Britta Feige; Erik Wissner; Andreas Metzner; Anita Arya; Shibu Mathew; Hisaki Makimoto; Peter Wohlmuth; Feifan Ouyang; Karl-Heinz Kuck; Roland Richard Tilz
Journal:  Clin Res Cardiol       Date:  2013-07-30       Impact factor: 5.460

10.  Atrial fibrillation: its prevalence and risk factor profile in the German general population.

Authors:  Renate B Schnabel; Sandra Wilde; Philipp S Wild; Thomas Munzel; Stefan Blankenberg
Journal:  Dtsch Arztebl Int       Date:  2012-04-20       Impact factor: 5.594

View more
  1 in total

1.  Two-dimensional versus three-dimensional transesophageal echocardiography in percutaneous left atrial appendage occlusion.

Authors:  Witold Streb; Katarzyna Mitręga; Tomasz Podolecki; Magdalena Szymała; Anna Leopold-Jadczyk; Tomasz Kukulski; Zbigniew Kalarus
Journal:  Cardiol J       Date:  2018-03-07       Impact factor: 2.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.