Literature DB >> 27925472

Image-guided radiotherapy for prostate cancer in the United Kingdom: a national survey.

Hemal Ariyaratne1, Hayley Chesham2, Roberto Alonzi1.   

Abstract

OBJECTIVE: To survey the technology and practice of image-guided radiotherapy (IGRT) for prostate cancer in the UK.
METHODS: A pre-tested semi-structured online questionnaire was sent to National Health Service (NHS) and private radiotherapy providers in the UK between March and April 2014. The survey was carried out on the Opinio© online platform.
RESULTS: There was a high survey response rate of 83%. There is widespread use of intensity-modulated radiotherapy and advanced verification imaging modalities. Cone-beam CT (CBCT) is the main verification imaging modality in radical prostate radiotherapy, used in 66% of UK centres. Fiducial markers in combination with imaging were used in 30% of centres. Over half the centres used a daily imaging schedule, with a Day 1-3 frequency followed by weekly frequency used less commonly. 26% of centres used daily CBCT.
CONCLUSION: There is widespread use of volumetric verification imaging with CBCT for prostate radiotherapy in the UK. There is no consensus on the optimal verification imaging schedule. Advances in knowledge: This survey provides an insight into contemporary UK practice of IGRT for prostate cancer, both in the NHS and private sector. It demonstrates the widespread use of CBCT imaging and highlights the need for further research to optimize the practice.

Entities:  

Mesh:

Year:  2016        PMID: 27925472      PMCID: PMC5685109          DOI: 10.1259/bjr.20160059

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  11 in total

1.  MRI/linac integration.

Authors:  Jan J W Lagendijk; Bas W Raaymakers; Alexander J E Raaijmakers; Johan Overweg; Kevin J Brown; Ellen M Kerkhof; Richard W van der Put; Björn Hårdemark; Marco van Vulpen; Uulke A van der Heide
Journal:  Radiother Oncol       Date:  2007-11-26       Impact factor: 6.280

2.  Long-term results of the M. D. Anderson randomized dose-escalation trial for prostate cancer.

Authors:  Deborah A Kuban; Susan L Tucker; Lei Dong; George Starkschall; Eugene H Huang; M Rex Cheung; Andrew K Lee; Alan Pollack
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-08-31       Impact factor: 7.038

3.  Radiotherapy equipment and departments in the European countries: final results from the ESTRO-HERO survey.

Authors:  Cai Grau; Noémie Defourny; Julian Malicki; Peter Dunscombe; Josep M Borras; Mary Coffey; Ben Slotman; Marta Bogusz; Chiara Gasparotto; Yolande Lievens; Arianit Kokobobo; Felix Sedlmayer; Elena Slobina; Karen Feyen; Tatiana Hadjieva; Karel Odrazka; Jesper Grau Eriksen; Jana Jaal; Ritva Bly; Bruno Chauvet; Normann Willich; Csaba Polgar; Jakob Johannsson; Moya Cunningham; Stefano Magrini; Vydmantas Atkocius; Michel Untereiner; Martin Pirotta; Vanja Karadjinovic; Sverre Levernes; Krystol Sladowski; Maria Lurdes Trigo; Barbara Šegedin; Aurora Rodriguez; Magnus Lagerlund; Bert Pastoors; Peter Hoskin; Jaap Vaarkamp; Ramon Cleries Soler
Journal:  Radiother Oncol       Date:  2014-10-31       Impact factor: 6.280

4.  A survey of image-guided radiation therapy use in the United States.

Authors:  Daniel R Simpson; Joshua D Lawson; Sameer K Nath; Brent S Rose; Arno J Mundt; Loren K Mell
Journal:  Cancer       Date:  2010-08-15       Impact factor: 6.860

5.  Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate.

Authors:  Douglas J Moseley; Elizabeth A White; Kirsty L Wiltshire; Tara Rosewall; Michael B Sharpe; Jeffrey H Siewerdsen; Jean-Pierre Bissonnette; Mary Gospodarowicz; Padraig Warde; Charles N Catton; David A Jaffray
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-01       Impact factor: 7.038

Review 6.  Survey of the availability and use of advanced radiotherapy technology in the UK.

Authors:  W P M Mayles
Journal:  Clin Oncol (R Coll Radiol)       Date:  2010-07-27       Impact factor: 4.126

7.  Update of Dutch multicenter dose-escalation trial of radiotherapy for localized prostate cancer.

Authors:  Abrahim Al-Mamgani; Wim L J van Putten; Wilma D Heemsbergen; Geert J L H van Leenders; Annerie Slot; Michel F H Dielwart; Luca Incrocci; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-05-19       Impact factor: 7.038

8.  Improved clinical outcomes with high-dose image guided radiotherapy compared with non-IGRT for the treatment of clinically localized prostate cancer.

Authors:  Michael J Zelefsky; Marisa Kollmeier; Brett Cox; Anthony Fidaleo; Dahlia Sperling; Xin Pei; Brett Carver; Jonathan Coleman; Michael Lovelock; Margie Hunt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-02-11       Impact factor: 7.038

9.  An organ and effective dose study of XVI and OBI cone-beam CT systems.

Authors:  Daniel E Hyer; Christopher F Serago; Siyong Kim; Jonathan G Li; David E Hintenlang
Journal:  J Appl Clin Med Phys       Date:  2010-04-17       Impact factor: 2.102

10.  Escalated-dose versus control-dose conformal radiotherapy for prostate cancer: long-term results from the MRC RT01 randomised controlled trial.

Authors:  David P Dearnaley; Gordana Jovic; Isabel Syndikus; Vincent Khoo; Richard A Cowan; John D Graham; Edwin G Aird; David Bottomley; Robert A Huddart; Chakiath C Jose; John H L Matthews; Jeremy L Millar; Claire Murphy; J Martin Russell; Christopher D Scrase; Mahesh K B Parmar; Matthew R Sydes
Journal:  Lancet Oncol       Date:  2014-02-26       Impact factor: 41.316

View more
  5 in total

1.  Are cone beam CT image matching skills transferrable from planning CT to planning MRI for MR-only prostate radiotherapy?

Authors:  Rachel L Brooks; Hazel M McCallum; Rachel A Pearson; Karen Pilling; Jonathan Wyatt
Journal:  Br J Radiol       Date:  2021-04-29       Impact factor: 3.039

Review 2.  Recent advances in radiation oncology.

Authors:  Cristina Garibaldi; Barbara Alicja Jereczek-Fossa; Giulia Marvaso; Samantha Dicuonzo; Damaris Patricia Rojas; Federica Cattani; Anna Starzyńska; Delia Ciardo; Alessia Surgo; Maria Cristina Leonardi; Rosalinda Ricotti
Journal:  Ecancermedicalscience       Date:  2017-11-30

3.  The accuracy of Magnetic Resonance - Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy.

Authors:  Jonathan J Wyatt; Rachel L Brooks; Dean Ainslie; Emily Wilkins; Elizabeth Raven; Karen Pilling; Rachel A Pearson; Hazel M McCallum
Journal:  Phys Imaging Radiat Oncol       Date:  2019-12-05

4.  Factors affecting accuracy and precision in ultrasound guided radiotherapy.

Authors:  Alexander Grimwood; Karen Thomas; Sally Kember; Georgina Aldis; Rebekah Lawes; Beverley Brigden; Jane Francis; Emer Henegan; Melanie Kerner; Louise Delacroix; Alexandra Gordon; Alison Tree; Emma J Harris; Helen A McNair
Journal:  Phys Imaging Radiat Oncol       Date:  2021-05-29

5.  CBCT imaging: a simple approach for optimising and evaluating concomitant imaging doses, based on patient-specific attenuation, during radiotherapy pelvis treatment.

Authors:  Caroline Ordóñez-Sanz; Mark Cowen; Neda Shiravand; Niall D MacDougall
Journal:  Br J Radiol       Date:  2021-08-01       Impact factor: 3.039

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.