Contact Force and Atrial Fibrillation Ablation.

W Ullah1, R J Schilling1, T Wong1.   

Abstract

Catheters able to measure the force and vector of contact between the catheter tip and myocardium are now available. Pre-clinical work has established that the degree of contact between the radiofrequency ablation catheter and myocardium correlates with the size of the delivered lesion. Excess contact is associated with steam pops and perforation. Catheter contact varies within the left atrium secondary to factors including respiration, location, atrial rhythm and the trans-septal catheter delivery technology used. Compared with procedures performed without contact force (CF)-sensing, the use of this technology has, in some studies, been found to improve complication rates, procedure and fluoroscopy times, and success rates. However, for each of these parameters there are also studies suggesting a lack of difference from the availability of CF data. Nevertheless, CF-sensing technology has been adopted as a standard of care in many institutions. It is likely that use of CF-sensing technology will allow for the optimization of each individual radiofrequency application to maximize efficacy and procedural safety. Recent work has attempted to define what these optimal targets should be, and approaches to do this include assessing for sites of pulmonary vein reconnection after ablation, or comparing the impedance response to ablation. Based on such work, it is apparent that factors including mean CF, force time integral (the area under the force-time curve) and contact stability are important determinants of ablation efficacy. Multicenter prospective randomized data are lacking in this field and required to define the CF parameters required to produce optimal ablation.

Entities:  

Keywords:  Atrial Fibrillation; Catheter Ablation; Contact Force

Year:  2016        PMID: 27909471      PMCID: PMC5089484          DOI: 10.4022/jafib.1282

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  53 in total

1.  Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm.

Authors:  Javier E Sanchez; G Neal Kay; Michael E Benser; Jeffrey A Hall; Gregory P Walcott; William M Smith; Raymond E Ideker
Journal:  J Interv Card Electrophysiol       Date:  2003-02       Impact factor: 1.900

2.  Popping phenomena in temperature-controlled radiofrequency ablation: when and why do they occur?

Authors:  O J Eick; B Gerritse; B Schumacher
Journal:  Pacing Clin Electrophysiol       Date:  2000-02       Impact factor: 1.976

3.  Regional atrial distensibility.

Authors:  B D Hoit; R A Walsh
Journal:  Am J Physiol       Date:  1992-05

4.  Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study.

Authors:  Jason G Andrade; George Monir; Scott J Pollak; Paul Khairy; Marc Dubuc; Denis Roy; Mario Talajic; Marc Deyell; Léna Rivard; Bernard Thibault; Peter G Guerra; Stanley Nattel; Laurent Macle
Journal:  Heart Rhythm       Date:  2014-07-25       Impact factor: 6.343

5.  In vivo contact force measurements and correlation with left atrial anatomy during catheter ablation of atrial fibrillation.

Authors:  Fabienne Schluermann; Tobias Krauss; Juergen Biermann; Maximilian Hartmann; Luca Trolese; Gregor Pache; Christoph Bode; Stefan Asbach
Journal:  Europace       Date:  2015-03-04       Impact factor: 5.214

6.  Tissue heating during radiofrequency catheter ablation: a thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall.

Authors:  D E Haines; D D Watson
Journal:  Pacing Clin Electrophysiol       Date:  1989-06       Impact factor: 1.976

7.  Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: a multicenter study of 600 patients.

Authors:  Julian W E Jarman; Sandeep Panikker; Moloy DAS; Gareth J Wynn; Waqas Ullah; Andrianos Kontogeorgis; Shouvik K Haldar; Preya J Patel; Wajid Hussain; Vias Markides; Dhiraj Gupta; Richard J Schilling; Tom Wong
Journal:  J Cardiovasc Electrophysiol       Date:  2015-02-11

8.  Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: a prospective case control study.

Authors:  Shouvik Haldar; Julian W E Jarman; Sandeep Panikker; David G Jones; Tushar Salukhe; Dhiraj Gupta; Gareth Wynn; Wajid Hussain; Vias Markides; Tom Wong
Journal:  Int J Cardiol       Date:  2012-12-04       Impact factor: 4.164

9.  Factors affecting catheter contact in the human left atrium and their impact on ablation efficacy.

Authors:  Waqas Ullah; Ross J Hunter; Victoria Baker; Mehul B Dhinoja; Simon Sporton; Mark J Earley; Richard J Schilling
Journal:  J Cardiovasc Electrophysiol       Date:  2014-10-14

10.  Cardiac magnetic resonance and electroanatomical mapping of acute and chronic atrial ablation injury: a histological validation study.

Authors:  James L Harrison; Henrik K Jensen; Sarah A Peel; Amedeo Chiribiri; Anne K Grøndal; Lars Ø Bloch; Steen F Pedersen; Jacob F Bentzon; Christoph Kolbitsch; Rashed Karim; Steven E Williams; Nick W Linton; Kawal S Rhode; Jaswinder Gill; Michael Cooklin; C A Rinaldi; Matthew Wright; Won Y Kim; Tobias Schaeffter; Reza S Razavi; Mark D O'Neill
Journal:  Eur Heart J       Date:  2014-01-12       Impact factor: 29.983

View more
  5 in total

Review 1.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

Review 2.  Very low tidal volume, high-frequency ventilation in atrial fibrillation ablation: a systematic review.

Authors:  Anis John Kadado; Kyle Gobeil; Fadi Fakhoury; Abdullah Pervaiz; Fadi Chalhoub
Journal:  J Interv Card Electrophysiol       Date:  2022-01-14       Impact factor: 1.759

3.  Use of Intraprocedural Ibutilide During Stepwise Ablation of Long-Standing Persistent Atrial Fibrillation.

Authors:  Andres Enriquez; Javad Hashemi; Kevin Michael; Hoshiar Abdollah; Christopher Simpson; Adrian Baranchuk; Damian Redfearn
Journal:  J Atr Fibrillation       Date:  2018-04-30

4.  Pulmonary vein isolation for atrial fibrillation: Does ablation technique influence outcome?

Authors:  S A Reddy; S L Nethercott; B V Khialani; M S Virdee
Journal:  Indian Heart J       Date:  2021-10-29

5.  Impact of Contact Force-Sensing Catheters on Fluoroscopy Time in Interventional Electrophysiology: A European Survey.

Authors:  Lukas Fiedler; Hermann Blessberger; Pawel Balsam; Tom De Potter; Piotr Buchta; Sabine Ernst; Victor Waldmann; Francisco Moscoso Costa; Stefan Bogdan; Alexander Nahler; Denis Hrncic; Thomas Lambert; Robert Schönbauer; Michael Pfeffer; Franz Xaver Roithinger; Clemens Steinwender; Jedrzej Kosiuk
Journal:  J Clin Med       Date:  2022-02-28       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.