Respiratory motion compensation for simultaneous PET/MR based on highly undersampled MR data.

Christopher M Rank1, Thorsten Heußer1, Andreas Wetscherek2, Martin T Freitag3, Oliver Sedlaczek3, Heinz-Peter Schlemmer3, Marc Kachelrieß1.   

Abstract

PURPOSE: Positron emission tomography (PET) of the thorax region is impaired by respiratory patient motion. To account for motion, the authors propose a new method for PET/magnetic resonance (MR) respiratory motion compensation (MoCo), which uses highly undersampled MR data with acquisition times as short as 1 min/bed.
METHODS: The proposed PET/MR MoCo method (4D jMoCo PET) uses radial MR data to estimate the respiratory patient motion employing MR joint motion estimation and image reconstruction with temporal median filtering. Resulting motion vector fields are incorporated into the system matrix of the PET reconstruction. The proposed approach is evaluated for the thorax region utilizing a PET/MR simulation with 1 min MR acquisition time and simultaneous PET/MR measurements of six patients with MR acquisition times of 1 and 5 min and radial undersampling factors of 11.2 and 2.2, respectively. Reconstruction results are compared to 3D PET, 4D gated PET and a standard MoCo method (4D sMoCo PET), which performs iterative image reconstruction and motion estimation sequentially. Quantitative analysis comprises the parameters SUVmean, SUVmax, full width at half-maximum/lesion volume, contrast and signal-to-noise ratio.
RESULTS: For simulated PET data, our quantitative analysis shows that the proposed 4D jMoCo PET approach with temporal filtering achieves the best quantification accuracy of all tested reconstruction methods with a mean absolute deviation of 2.3% when compared to the ground truth. For measured PET patient data, the mean absolute deviation of 4D jMoCo PET using a 1 min MR acquisition for motion estimation is 2.1% relative to the 5 min MR acquisition. This demonstrates a robust behavior even in case of strong undersampling at MR acquisition times as short as 1 min. In contrast, 4D sMoCo PET shows considerable reduction of quantification accuracy for the 1 min MR acquisition time. Relative to 3D PET, the proposed 4D jMoCo PET approach with temporal filtering yields an average increase of SUVmean, SUVmax, and contrast of 29.9% and 13.8% for simulated and measured PET data, respectively.
CONCLUSIONS: Employing artifact-robust motion estimation enables PET/MR respiratory MoCo with MR acquisition times as short as 1 min/bed improving PET image quality and quantification accuracy.

Entities:  

Mesh:

Year:  2016        PMID: 27908174     DOI: 10.1118/1.4966128

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Comparison of the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo).

Authors:  Onofrio A Catalano; Lale Umutlu; Niccolo Fuin; Matthew Louis Hibert; Michele Scipioni; Stefano Pedemonte; Mark Vangel; Andreea Maria Catana; Ken Herrmann; Felix Nensa; David Groshar; Umar Mahmood; Bruce R Rosen; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-07-11       Impact factor: 9.236

2.  MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging.

Authors:  Y Petibon; T Sun; P K Han; C Ma; G El Fakhri; J Ouyang
Journal:  Phys Med Biol       Date:  2019-10-04       Impact factor: 3.609

Review 3.  What scans we will read: imaging instrumentation trends in clinical oncology.

Authors:  Thomas Beyer; Luc Bidaut; John Dickson; Marc Kachelriess; Fabian Kiessling; Rainer Leitgeb; Jingfei Ma; Lalith Kumar Shiyam Sundar; Benjamin Theek; Osama Mawlawi
Journal:  Cancer Imaging       Date:  2020-06-09       Impact factor: 3.909

4.  Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR.

Authors:  Thibault Marin; Yanis Djebra; Paul K Han; Yanis Chemli; Isabelle Bloch; Georges El Fakhri; Jinsong Ouyang; Yoann Petibon; Chao Ma
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 3.609

Review 5.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

Review 6.  Adapting Imaging Protocols for PET-CT and PET-MRI for Immunotherapy Monitoring.

Authors:  Bettina Beuthien-Baumann; Christos Sachpekidis; Regula Gnirs; Oliver Sedlaczek
Journal:  Cancers (Basel)       Date:  2021-11-30       Impact factor: 6.639