Literature DB >> 27895990

Influence of coherence length, signal-to-noise ratio, log transform, and low-pass filtering on layer thickness assessment with OCT in the retina.

Nomdo M Jansonius1, Joel Cervantes2, Maddipatla Reddikumar2, Barry Cense2.   

Abstract

Optical coherence tomography (OCT) images of the retina are inevitably affected by the finite width of the coherence function and noise. To make low-reflective layers visible, the raw OCT signal is log transformed; to reduce the effect of noise the images can be low-pass filtered. We determined the effects of these operations on layer thickness assessment, as a function of signal-to-noise ratio (SNR), by performing measurements in a phantom eye and modeling. The log transform appeared to be the key factor in a SNR-dependent overestimation of peak widths and a less predictive bias in the widths of low-reflective layers.

Keywords:  (100.0100) Image processing; (100.3008) Image recognition, algorithms and filters; (110.0113) Imaging through turbid media; (110.4500) Optical coherence tomography; (170.4460) Ophthalmic optics and devices; (170.4470) Ophthalmology

Year:  2016        PMID: 27895990      PMCID: PMC5119590          DOI: 10.1364/BOE.7.004490

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  22 in total

1.  A theory of maximizing sensory information.

Authors:  J H van Hateren
Journal:  Biol Cybern       Date:  1992       Impact factor: 2.086

2.  Optical density filters modeling media opacities cause decreased SD-OCT retinal layer thickness measurements with inter- and intra-individual variation.

Authors:  Stanley Darma; Pauline H B Kok; Thomas J T P van den Berg; Michael D Abràmoff; Dirk J Faber; Caroline A Hulsman; Frank Zantvoord; Maarten P Mourits; Reinier O Schlingemann; Frank D Verbraak
Journal:  Acta Ophthalmol       Date:  2014-12-08       Impact factor: 3.761

3.  Comparison of retinal nerve fiber layer thickness measurements by spectral-domain optical coherence tomography systems using a phantom eye model.

Authors:  Roy de Kinkelder; Daniel M de Bruin; Frank D Verbraak; Ton G van Leeuwen; Dirk J Faber
Journal:  J Biophotonics       Date:  2012-07-19       Impact factor: 3.207

4.  Theory of edge detection.

Authors:  D Marr; E Hildreth
Journal:  Proc R Soc Lond B Biol Sci       Date:  1980-02-29

5.  Histologic correlation of in vivo optical coherence tomography images of the human retina.

Authors:  Teresa C Chen; Barry Cense; Joan W Miller; Peter A D Rubin; Daniel G Deschler; Evangelos S Gragoudas; Johannes F de Boer
Journal:  Am J Ophthalmol       Date:  2006-06       Impact factor: 5.258

6.  Macular segmentation with optical coherence tomography.

Authors:  Hiroshi Ishikawa; Daniel M Stein; Gadi Wollstein; Siobahn Beaton; James G Fujimoto; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-06       Impact factor: 4.799

7.  Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: patterns of retinal nerve fiber layer progression.

Authors:  Christopher Kai-Shun Leung; Marco Yu; Robert N Weinreb; Gilda Lai; Guihua Xu; Dennis Shun-Chiu Lam
Journal:  Ophthalmology       Date:  2012-06-05       Impact factor: 12.079

8.  Effect of cataract and its removal on ganglion cell complex thickness and peripapillary retinal nerve fiber layer thickness measurements by fourier-domain optical coherence tomography.

Authors:  Yusuke Nakatani; Tomomi Higashide; Shinji Ohkubo; Hisashi Takeda; Kazuhisa Sugiyama
Journal:  J Glaucoma       Date:  2013-08       Impact factor: 2.503

9.  Evaluation of Retinal Nerve Fiber Layer Thickness and Ganglion Cell Complex Progression Rates in Healthy, Ocular Hypertensive, and Glaucoma Eyes With the Avanti RTVue-XR Optical Coherence Tomograph Based on 5-Year Follow-up.

Authors:  Gábor Holló; Qienyuan Zhou
Journal:  J Glaucoma       Date:  2016-10       Impact factor: 2.503

10.  Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation.

Authors:  Stephanie J Chiu; Xiao T Li; Peter Nicholas; Cynthia A Toth; Joseph A Izatt; Sina Farsiu
Journal:  Opt Express       Date:  2010-08-30       Impact factor: 3.894

View more
  4 in total

1.  Testing a phantom eye under various signal-to-noise ratio conditions using eleven different OCT devices.

Authors:  Tuomas Heikka; Giovanni Ometto; Giovanni Montesano; Scott Rowe; Nomdo M Jansonius; David P Crabb
Journal:  Biomed Opt Express       Date:  2020-02-07       Impact factor: 3.732

2.  Structure-Function Analysis in Macular Drusen With Mesopic and Scotopic Microperimetry.

Authors:  Giovanni Montesano; Giovanni Ometto; Bethany E Higgins; Costanza Iester; Konstantinos Balaskas; Adnan Tufail; Usha Chakravarthy; Ruth E Hogg; David P Crabb
Journal:  Transl Vis Sci Technol       Date:  2020-12-28       Impact factor: 3.283

3.  Rapid Objective Testing of Visual Function Matched to the ETDRS Grid and Its Diagnostic Power in Age-Related Macular Degeneration.

Authors:  Bhim B Rai; Faran Sabeti; Corinne F Carle; Emilie M Rohan; Josh P van Kleef; Rohan W Essex; Richard C Barry; Ted Maddess
Journal:  Ophthalmol Sci       Date:  2022-03-18

4.  Influence of optic disc-fovea distance on macular thickness measurements with OCT in healthy myopic eyes.

Authors:  Kunliang Qiu; Geng Wang; Riping Zhang; Xuehui Lu; Mingzhi Zhang; Nomdo M Jansonius
Journal:  Sci Rep       Date:  2018-03-27       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.