Literature DB >> 27884403

Chairside CAD/CAM materials. Part 2: Flexural strength testing.

Michael Wendler1, Renan Belli2, Anselm Petschelt2, Daniel Mevec3, Walter Harrer3, Tanja Lube3, Robert Danzer3, Ulrich Lohbauer4.   

Abstract

OBJECTIVE: Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory.
METHODS: Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm3) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens.
RESULTS: A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. SIGNIFICANCE: The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry.
Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  4-point bending; B3B-test; Biaxial strength; CAD/CAM; Dental ceramics; Resin composites

Mesh:

Substances:

Year:  2016        PMID: 27884403     DOI: 10.1016/j.dental.2016.10.008

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  23 in total

1.  Polishing effects and wear performance of chairside CAD/CAM materials.

Authors:  Mike Matzinger; Sebastian Hahnel; Verena Preis; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-05-16       Impact factor: 3.573

2.  Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia.

Authors:  M Wendler; M R Kaizer; R Belli; U Lohbauer; Y Zhang
Journal:  Dent Mater       Date:  2020-01-30       Impact factor: 5.304

3.  Microstructural development during heat treatment of a commercially available dental-grade lithium disilicate glass-ceramic.

Authors:  Angel L Ortiz; Oscar Borrero-López; Fernando Guiberteau; Yu Zhang
Journal:  Dent Mater       Date:  2019-03-01       Impact factor: 5.304

4.  Load-bearing capacity of lithium disilicate and ultra-translucent zirconias.

Authors:  Jing Yan; Marina R Kaizer; Yu Zhang
Journal:  J Mech Behav Biomed Mater       Date:  2018-08-21

5.  Physico-mechanical properties and bacterial adhesion of resin composite CAD/CAM blocks: An in-vitro study.

Authors:  Mohamed M Mokhtar; Dina S Farahat; Waleed Eldars; Manal F Osman
Journal:  J Clin Exp Dent       Date:  2022-05-01

6.  The effect of adjustment and finishing procedure on roughness, strength, and phase transformation of monolithic zirconia.

Authors:  Isıl Ozturk; Ipek Caglar; Zeynep Yesil Duymus
Journal:  Clin Oral Investig       Date:  2022-03-16       Impact factor: 3.606

7.  Retention of CAD/CAM resin composite crowns following different bonding protocols.

Authors:  Amir H Nejat; Jinwhan Lee; Shreya Shah; Chee Paul Lin; Prajakta Kulkarni; Ramakiran Chavali; Nathaniel C Lawson
Journal:  Am J Dent       Date:  2018-04       Impact factor: 1.522

8.  Fracture load of CAD/CAM-fabricated and 3D-printed composite crowns as a function of material thickness.

Authors:  Moritz Zimmermann; Andreas Ender; Gustav Egli; Mutlu Özcan; Albert Mehl
Journal:  Clin Oral Investig       Date:  2018-10-27       Impact factor: 3.573

9.  Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns.

Authors:  Ulrich Lohbauer; Renan Belli; Marco S Cune; Ulf Schepke
Journal:  SAGE Open Med Case Rep       Date:  2017-11-22

10.  Effect of Endocrown Restorations with Different CAD/CAM Materials: 3D Finite Element and Weibull Analyses.

Authors:  Laden Gulec; Nuran Ulusoy
Journal:  Biomed Res Int       Date:  2017-09-28       Impact factor: 3.411

View more