Literature DB >> 3490554

Fundamentals of 180 degree acquisition and reconstruction in SPECT imaging.

R L Eisner, D J Nowak, R Pettigrew, W Fajman.   

Abstract

The accuracy of the reconstructed images obtained from a 180 degrees SPECT acquisition is directly related to the effects of resolution and attenuation in the acquired projection data. Computer simulation studies show that the tomographic point spread functions and the quality of 201Tl myocardial perfusion transaxial images depend upon the specific 180 degrees arc used for reconstruction. Significant distortions are predicted in 201Tl myocardial images reconstructed from both 180 degrees and 360 degree scans; with signal to noise being significantly better for 180 degree scans. An anterior 180 degrees scan with a starting angle between right lateral and 45 degrees RAO in 201Tl myocardial imaging is recommended. Reconstructed images acquired from 180 degrees and 360 degree elliptical orbits are predicted to show more distortion than those obtained from circular acquisitions.

Mesh:

Substances:

Year:  1986        PMID: 3490554

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  19 in total

1.  The challenge of quantifying defect size and severity: reality versus algorithm.

Authors:  R L Eisner; R E Patterson
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

2.  Differences due to collimator blurring in cardiac images with use of circular and elliptic camera orbits.

Authors:  A Abufadel; R L Eisner; R W Schafer
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

3.  Estimation of attenuation maps from scatter and photopeak window single photon-emission computed tomographic images of technetium 99m-labeled sestamibi.

Authors:  T S Pan; M A King; D S Luo; S T Dahlberg; B J Villegas
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

4.  Procedure guidelines for radionuclide myocardial perfusion imaging.

Authors:  C Anagnostopoulos; M Harbinson; A Kelion; K Kundley; C Y Loong; A Notghi; E Reyes; W Tindale; S R Underwood
Journal:  Heart       Date:  2004-01       Impact factor: 5.994

5.  Assessment of geometrical distortion and activity distribution after attenuation correction: A SPECT phantom study.

Authors:  Sara Lappi; Simonetta Lazzari; Graziella Sarti; Pierluigi Pieri
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

6.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

7.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

8.  Comparison of 180 degrees and 360 degrees acquisition for myocardial perfusion SPECT with compensation for attenuation, detector response, and scatter: Monte Carlo and mathematical observer results.

Authors:  Xin He; Jonathan M Links; Karen L Gilland; Benjamin M W Tsui; Eric C Frey
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

Review 9.  Myocardial perfusion and function: single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Olakunle O Akinboboye; Daniel S Berman; Elias H Botvinick; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; Regina S Druz; Edward P Ficaro; James R Galt; Ravi K Garg; Guido Germano; Gary V Heller; Milena J Henzlova; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Robert A Quaife; Terrence D Ruddy; Senthil N Sundaram; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

10.  Experimental validation of a new quantitative method for the analysis of infarct size by cardiac perfusion tomography (SPECT).

Authors:  L Mortelmans; J Nuyts; J Vanhaecke; A Verbruggen; M De Roo; H De Geest; P Svetens; F Van de Werf
Journal:  Int J Card Imaging       Date:  1993-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.