Literature DB >> 27867291

Ubiquitous Nature of Distal Athero/Thromboembolic Events during Lower Extremity Atherectomy Procedures Involving the Superficial Femoral Artery.

Najam Wasty1, M Z Khakwani1, Spas Kotev1, Catalin Boiangiu1, Omar Hasan1, Manjusha Anna1, Rajiv Tayal1, Khalil Kaid1, Gail Baker1, Marc Cohen1.   

Abstract

This study aims to evaluate occurrence, size, composition, and clinical significance of embolized debris during superficial femoral artery atherectomy using all commercially available atherectomy devices. Distal athero/thromboembolic events (DATE) are a universal phenomenon in lower extremity atherectomy procedures (LEAPs) due to the sheer volume of atheroma and the thrombus burden in peripheral arterial disease. Some of these events can be clinically significant. We prospectively gathered clinical and histopathological data on all commercially available atherectomy devices by using embolic protection devices (EPD) in every case. After intervention, the contents of EPD were examined both microscopically and macroscopically. Data from 59 consecutive patients undergoing LEAP were analyzed. DATE occurred 100% of the time. The composition of particulate debris varied with the device used. Grossly visible agglomerated debris was captured by the filter in the majority of patients 54/59 (91.5%). Clinically significant debris, defined by the Preventing Lower Extremity Distal Embolization Using Embolic Filter Protection registry as particle diameter > 0.2 cm, was found in 33/59 (56%) patients. The size of captured debris particles ranged from 0.1 to 2.4 mm. While DATE occurred in all patients, clinically significant DATE occurred in 56% patients undergoing LEAP regardless of the atherectomy device. In spite of a large fraction of the clinically significant debris occurring on our routine dual antiplatelet regimen, no patient suffered an amputation. Although DATE was prevented by the use of EPD in all 59 cases, more data are needed to determine whether the use of EPD translates into a long-term clinical benefit. Use of EPD and optimal thromboprophylaxis should be considered in patients, especially in the setting of compromised distal runoff.

Entities:  

Keywords:  atherectomy; cardiac catheterization; endovascular procedures; peripheral arterial thromboembolism

Year:  2016        PMID: 27867291      PMCID: PMC5114138          DOI: 10.1055/s-0036-1587694

Source DB:  PubMed          Journal:  Int J Angiol        ISSN: 1061-1711


  20 in total

1.  Incidence of new brain lesions after carotid stenting with and without cerebral protection.

Authors:  Andreas Kastrup; Thomas Nägele; Klaus Gröschel; Friederike Schmidt; Eva Vogler; Jörg Schulz; Ulrike Ernemann
Journal:  Stroke       Date:  2006-08-03       Impact factor: 7.914

2.  Mortality over a period of 10 years in patients with peripheral arterial disease.

Authors:  M H Criqui; R D Langer; A Fronek; H S Feigelson; M R Klauber; T J McCann; D Browner
Journal:  N Engl J Med       Date:  1992-02-06       Impact factor: 91.245

3.  Percutaneous lower-extremity arterial interventions with primary balloon angioplasty versus Silverhawk atherectomy and adjunctive balloon angioplasty: randomized trial.

Authors:  Nicolas W Shammas; Denise Coiner; Gail A Shammas; Eric J Dippel; Lori Christensen; Michael Jerin
Journal:  J Vasc Interv Radiol       Date:  2011-07-14       Impact factor: 3.464

4.  Distal embolic protection during percutaneous coronary intervention in patients with acute coronary syndromes: the RUBY study.

Authors:  Antonio L Bartorelli; Tian-Hai Koh; Francesco Di Pede; Bernard Reimers; Leif Thuesen; Franz W Amann; Franco Fabbiocchi; Harry Suryapranata
Journal:  Acute Card Care       Date:  2006

Review 5.  Arterial remodeling and coronary artery disease: the concept of "dilated" versus "obstructive" coronary atherosclerosis.

Authors:  P Schoenhagen; K M Ziada; D G Vince; S E Nissen; E M Tuzcu
Journal:  J Am Coll Cardiol       Date:  2001-08       Impact factor: 24.094

6.  Slow-flow phenomenon during carotid artery intervention with embolic protection devices: predictors and clinical outcome.

Authors:  Ivan P Casserly; Alex Abou-Chebl; Robert B Fathi; David S Lee; Jacqueline Saw; Jose E Exaire; Samir R Kapadia; Christopher T Bajzer; Jay S Yadav
Journal:  J Am Coll Cardiol       Date:  2005-09-23       Impact factor: 24.094

7.  Prediction of distal embolization during percutaneous coronary intervention in saphenous vein grafts.

Authors:  William Joseph van Gaal; Robin Patrick Choudhury; Italo Porto; Keith Channon; Adrian Banning; Vladimir Dzavik; Rachael Ramsamujh; Sanh Bui; Daniel James Blackman
Journal:  Am J Cardiol       Date:  2007-01-04       Impact factor: 2.778

8.  Analysis of particulate debris after superficial femoral artery atherectomy.

Authors:  Khalil A Kaid; Rajeev Gopinathapillai; Fang Qian; Madhu Salvaji; Najam Wasty; Marc Cohen
Journal:  J Invasive Cardiol       Date:  2009-01       Impact factor: 2.022

9.  Morbidity and mortality in hypertensive adults with a low ankle/arm blood pressure index.

Authors:  A B Newman; K Sutton-Tyrrell; M T Vogt; L H Kuller
Journal:  JAMA       Date:  1993-07-28       Impact factor: 56.272

Review 10.  Noncoronary angioplasty.

Authors:  G J Becker; B T Katzen; M D Dake
Journal:  Radiology       Date:  1989-03       Impact factor: 11.105

View more
  2 in total

1.  State-of-the-Art Endovascular Therapies for the Femoropopliteal Segment: Are We There Yet?

Authors:  Ramya C Mosarla; Ehrin Armstrong; Yonatan Bitton-Faiwiszewski; Peter A Schneider; Eric A Secemsky
Journal:  J Soc Cardiovasc Angiogr Interv       Date:  2022-08-20

2.  Clinical Outcomes of Atherectomy Plus Drug-coated Balloon Versus Drug-coated Balloon Alone in the Treatment of Femoropopliteal Artery Disease.

Authors:  Jung-Joon Cha; Jae-Hwan Lee; Young-Guk Ko; Jae-Hyung Roh; Yong-Hoon Yoon; Yong-Joon Lee; Seung-Jun Lee; Sung-Jin Hong; Chul-Min Ahn; Jung-Sun Kim; Byeong-Keuk Kim; Donghoon Choi; Myeong-Ki Hong; Yangsoo Jang
Journal:  Korean Circ J       Date:  2021-10-28       Impact factor: 3.243

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.