Literature DB >> 27864600

Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT.

Amir A Borhani1, Matthew Kulzer2, Negaur Iranpour2, Anish Ghodadra2, Mark Sparrow2, Alessandro Furlan3, Mitchell E Tublin3.   

Abstract

OBJECTIVE: To assess the agreement between the true non-contrast (TNC) attenuation values of intra-abdominal structures and attenuation values obtained on virtual-unenhanced (VUE) images based on rapid kVp-switching dual-energy CT. The effects of contrast phase and patient characteristics (e.g., BMI, hematocrit, hemoglobin content) on VUE values were also investigated.
METHODS: Ninety four patients who underwent triphasic abdominal CT (liver mass protocol, n = 47; pancreas mass protocol, n = 47) between August 2014 and May 2015 were retrospectively reviewed. Unenhanced series was performed using conventional single-energy mode at 120 kVp. Late arterial and venous phase post-contrast series were obtained utilizing rapid kVp-switching dual-energy CT technique. VUE images were processed off of arterial (VUE-art) and venous (VUE-ven) phase series. Attenuation values of liver, pancreas, kidneys, adrenal glands, muscle, subcutaneous fat, aorta, IVC, and main portal vein were recorded on TNC and VUE sets of images. Attenuation values were compared using univariate linear regression and Student two-tailed paired t test.
RESULTS: There was excellent correlation between TNC, VUE-art, and VUE-ven attenuation values across all organs (p < 0.0001). Paired Student t test, however, showed significant difference between TNC and VUE-art attenuation of kidneys, right adrenal gland, paraspinal muscle, and aorta. There was also significant difference between TNC and VUE-ven attenuation of left kidney. Percentage of cases which had >10 HU difference between VUE and TNC for an individual was calculated which ranged between 13% (right kidney) and 42% (right adrenal gland).
CONCLUSION: Although the correlation between VUE and TNC attenuation values was excellent and mean difference between TNC and VUE attenuation values was negligible (ranging between -5.94 HU for paraspinal muscles to 6.2 HU in aorta), intra-patient analysis showed a considerable number of cases which had >10 HU difference between VUE and TNC. VUE-ven generally offered a better approximation of TNC values. Further optimization of post-processing algorithms might be necessary before complete replacement of TNC with VUE images.

Entities:  

Keywords:  Dual-energy CT; Rapid kVp-switching CT; Spectral CT; Virtual unenhanced

Mesh:

Substances:

Year:  2017        PMID: 27864600     DOI: 10.1007/s00261-016-0991-5

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  8 in total

1.  Diagnostic performance of dual-energy CT and subtraction CT for renal lesion detection and characterization.

Authors:  Ali Pourvaziri; Anushri Parakh; Amirkasra Mojtahed; Avinash Kambadakone; Dushyant Vasudeo Sahani
Journal:  Eur Radiol       Date:  2019-05-27       Impact factor: 5.315

Review 2.  Advanced imaging techniques for chronic pancreatitis.

Authors:  Anushri Parakh; Temel Tirkes
Journal:  Abdom Radiol (NY)       Date:  2020-05

Review 3.  Dual-energy CT: theoretical principles and clinical applications.

Authors:  Andrea Agostini; Alessandra Borgheresi; Alberto Mari; Chiara Floridi; Federico Bruno; Marina Carotti; Nicolò Schicchi; Antonio Barile; Stefania Maggi; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-12-02       Impact factor: 3.469

4.  Compatibility of true and virtual unenhanced attenuation in rapid kV-switching dual energy CT.

Authors:  İlkay Çamlıdağ
Journal:  Diagn Interv Radiol       Date:  2020-03       Impact factor: 2.630

5.  Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams.

Authors:  Usman Mahmood; Natally Horvat; Joao Vicente Horvat; Davinia Ryan; Yiming Gao; Gabriella Carollo; Rommel DeOcampo; Richard K Do; Seth Katz; Scott Gerst; C Ross Schmidtlein; Lawrence Dauer; Yusuf Erdi; Lorenzo Mannelli
Journal:  Eur J Radiol       Date:  2018-02-19       Impact factor: 3.528

Review 6.  Dual energy CT applications in pancreatic pathologies.

Authors:  Elizabeth George; Jeremy R Wortman; Urvi P Fulwadhva; Jennifer W Uyeda; Aaron D Sodickson
Journal:  Br J Radiol       Date:  2017-09-22       Impact factor: 3.039

7.  Dual-Energy CT Images: Pearls and Pitfalls.

Authors:  Anushri Parakh; Simon Lennartz; Chansik An; Prabhakar Rajiah; Benjamin M Yeh; Frank J Simeone; Dushyant V Sahani; Avinash R Kambadakone
Journal:  Radiographics       Date:  2021 Jan-Feb       Impact factor: 5.333

8.  Quantitative benchmarking of iodine imaging for two CT spectral imaging technologies: a phantom study.

Authors:  Vanja Harsaker; Kristin Jensen; Hilde Kjernlie Andersen; Anne Catrine Martinsen
Journal:  Eur Radiol Exp       Date:  2021-06-23
  8 in total