Literature DB >> 27863970

Treatment of distal anterior cerebral artery aneurysms with the Pipeline Embolization Device.

Erez Nossek1, Daniel W Zumofen2, Avi Setton3, Matthew B Potts4, Eytan Raz5, Maksim Shapiro5, Howard A Riina5, Maria Angeles De Miquel6, David J Chalif7, Peter K Nelson5.   

Abstract

Aneurysms of the anterior cerebral artery (ACA) located distal to the anterior communicating artery complex (ACOM) remain challenging to treat with surgical clip reconstruction as well as with endovascular coil-embolization strategies. We have treated five complex geometry distal ACA aneurysms with endoluminal reconstruction using the Pipeline Embolization Device (PED). Two aneurysms were of the dysplastic fusiform type. Three aneurysms were of complex saccular configuration. Three aneurysms were treated electively at the outset with PED. One patient had previously undergone aborted clip reconstruction, and one was treated for recurrent aneurysm growth after coil embolization. The mean diameter of the ACA in this cohort was 1.96mm proximal to the aneurysm and 1.79mm distal to the aneurysmal segment. A single PED of 2.5mm inner diameter was the sole treatment in four cases. Two PEDs, telescopically overlapped across the aneurysm, were used in the remaining case. All devices were deployed successfully. No parent artery occlusion or stenosis was observed. In all cases an associated branch vessel arising from the vicinity of the aneurysm or incorporated into its neck was covered by the endoluminal construct. At follow-up angiography, robust antegrade flow was maintained in the jailed branch. One patient experienced asymptomatic, delayed occlusion of the jailed branch. Complete aneurysm occlusion was seen in all patients. We confirm that PED can be deployed in parent vessels smaller than 2mm diameter, and that endoluminal reconstruction with the PED may be a safe and effective treatment alternative for selected distal ACA aneurysms.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aneurysm; Anterior cerebral artery; Flow diverter; Pericallosal; Pipeline

Mesh:

Year:  2016        PMID: 27863970     DOI: 10.1016/j.jocn.2016.10.041

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  8 in total

1.  The Silk Vista Baby: Initial experience and report of two cases.

Authors:  Pervinder Bhogal; Ken Wong; Christopher Uff; John Wadley; Hegoda Ld Makalanda
Journal:  Interv Neuroradiol       Date:  2019-03-31       Impact factor: 1.610

Review 2.  Coiling for an unruptured saccular aneurysm at the non-branching segment of the distal anterior cerebral artery: Case report and literature review.

Authors:  Kazushi Maeda; Yosuke Kawano; Naoki Maehara; Yuhei Michiwaki; Shintaro Nagaoka; Junji Uno; Hidefuku Gi; Yukihide Kanemoto
Journal:  Neuroradiol J       Date:  2020-02-04

3.  Treatment of Unruptured Distal Anterior Circulation Aneurysms with Flow-Diverter Stents: A Meta-Analysis.

Authors:  F Cagnazzo; P Perrini; C Dargazanli; P-H Lefevre; G Gascou; R Morganti; D di Carlo; I Derraz; C Riquelme; A Bonafe; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-14       Impact factor: 3.825

4.  Flow Diverting Stents in Cerebral Small Caliber Vessels (< 2 mm) for Aneurysm Treatment : A Three Center Retrospective Study.

Authors:  Sophia Hohenstatt; Sergio L Vinci; Dominik F Vollherbst; Agostino Tessitore; Niclas Schmitt; Antonio Pitrone; Antonio A Caragliano; Mariano Velo; Markus A Möhlenbruch; Aldo Paolucci
Journal:  Clin Neuroradiol       Date:  2022-06-29       Impact factor: 3.649

Review 5.  Intracranial Aneurysm: Diagnostic Monitoring, Current Interventional Practices, and Advances.

Authors:  Jason A Ellis; Erez Nossek; Annick Kronenburg; David J Langer; Rafael A Ortiz
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-10-24

6.  Toward Better Understanding of Flow Diversion in Bifurcation Aneurysms.

Authors:  M Shapiro; A Shapiro; E Raz; T Becske; H Riina; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2018-11-15       Impact factor: 3.825

7.  Safety and Efficacy of the Pipeline Embolization Device Use in the Outside Circle of Willis Located Intracranial Aneurysms: A Single-Center Experience.

Authors:  Sami Al Kasab; Waldo R Guerrero; Daichi Nakagawa; Edgar A Samaniego; Santiago Ortega-Gutierrez; David Hasan
Journal:  Interv Neurol       Date:  2019-01-16

8.  The Silk Vista Baby - The UK experience.

Authors:  P Bhogal; Hld Makalanda; K Wong; P Keston; J Downer; J C Du Plessis; A Nania; D Simonato; M Fuschi; W Chong; S O'Reilly; I Rennie
Journal:  Interv Neuroradiol       Date:  2021-06-02       Impact factor: 1.764

  8 in total