Literature DB >> 27853943

Endocardial voltage mapping of pulmonary veins with an ultra-high-resolution system to evaluate atrial myocardial extensions.

Francesco Santoro1,2, Christian Sohns3, Ardan M Saguner3, Natale Daniele Brunetti4, Christine Lemes3, Shibu Mathew3, Christian-H Heeger3, Bruno Reißmann3, Tilman Maurer3, Johannes Riedl3, Thomas Fink3, Kentaro Hayashi3, Feifan Ouyang3, Matteo Di Biase4, Karl-Heinz Kuck3, Andreas Metzner3.   

Abstract

INTRODUCTION: Atrial fibrillation (AF) is mainly triggered by arrhythmogenic foci originating from atrial myocardial extensions (MEs) into the pulmonary veins (PVs). Aim of the study was to evaluate endocardial voltage maps of PVs as a surrogate parameter for the extent of MEs in subjects with AF through a ultra-high-density mapping system.
METHODS: Sixty-four bipolar electrograms were recorded simultaneously from the Orion mini-basket catheter placed in 72 PVs of 18 consecutive patients with paroxysmal/persistent AF undergoing PV isolation (PVI). The Rhythmia system in conjunction with the Orion mini-basket catheter was utilized to create a bipolar electro-anatomic reconstruction of the left atrium and PVs.
RESULTS: Mean patients' age was 61 ± 10 years, 56% had paroxysmal and 44% persistent AF. Mean endocardial bipolar voltages in the PVs were as follows: 1.06 ± 0.34 mV in right superior PV, 1.14 ± 0.52 mV in right inferior PV, 1.15 ± 0.44 mV in left superior PV and 0.94 ± 0.44 in left inferior PV. PVs had no detectable endocardial signals in 7 out of 72 PVs (9%); a total of 29/72 PVs (40%) revealed a non-uniform arrangement of MEs. The area of MEs was significantly larger in the superior PVs compared to the inferior PVs (9.3 ± 4.7 vs 6.7 ± 4 cm2, p = 0.002). No statistical differences in terms of MEs length were found among PVs and according to type of AF.
CONCLUSION: In this pilot study using a ultra-high-resolution electro-anatomical mapping system, endocardial voltage maps of PVs as a surrogate parameter of MEs among patients with AF well correspond to previous data from histopathological studies.

Entities:  

Keywords:  Atrial fibrillation; Myocardial extensions; Myocardial sleeves; Orion; Pulmonary veins; Rhythmia system; Sleeves; Voltage map

Mesh:

Year:  2016        PMID: 27853943     DOI: 10.1007/s00392-016-1053-2

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  22 in total

1.  Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up.

Authors:  Feifan Ouyang; Roland Tilz; Julian Chun; Boris Schmidt; Erik Wissner; Thomas Zerm; Kars Neven; Bulent Köktürk; Melanie Konstantinidou; Andreas Metzner; Alexander Fuernkranz; Karl-Heinz Kuck
Journal:  Circulation       Date:  2010-11-22       Impact factor: 29.690

2.  Secular trends in incidence of atrial fibrillation in Olmsted County, Minnesota, 1980 to 2000, and implications on the projections for future prevalence.

Authors:  Yoko Miyasaka; Marion E Barnes; Bernard J Gersh; Stephen S Cha; Kent R Bailey; Walter P Abhayaratna; James B Seward; Teresa S M Tsang
Journal:  Circulation       Date:  2006-07-03       Impact factor: 29.690

3.  Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.

Authors:  Elad Anter; Cory M Tschabrunn; Fernando M Contreras-Valdes; Jianqing Li; Mark E Josephson
Journal:  Heart Rhythm       Date:  2015-05-19       Impact factor: 6.343

4.  Rapid high resolution electroanatomical mapping: evaluation of a new system in a canine atrial linear lesion model.

Authors:  Hiroshi Nakagawa; Atsushi Ikeda; Tushar Sharma; Ralph Lazzara; Warren M Jackman
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-03-05

5.  Left atrial myocardial extension onto pulmonary veins in humans: anatomic observations relevant for atrial arrhythmias.

Authors:  T Saito; K Waki; A E Becker
Journal:  J Cardiovasc Electrophysiol       Date:  2000-08

6.  Morphology of atrial myocardium in human pulmonary veins: a postmortem analysis in patients with and without atrial fibrillation.

Authors:  Rutger J Hassink; H Thomas Aretz; Jeremy Ruskin; David Keane
Journal:  J Am Coll Cardiol       Date:  2003-09-17       Impact factor: 24.094

7.  The myocardial sleeves of the pulmonary veins: potential implications for atrial fibrillation.

Authors:  N Roux; E Havet; P Mertl
Journal:  Surg Radiol Anat       Date:  2004-02-11       Impact factor: 1.246

8.  Anatomic characteristics of extensions of atrial myocardium into the pulmonary veins in subjects with and without atrial fibrillation.

Authors:  Ivana Kholová; Josef Kautzner
Journal:  Pacing Clin Electrophysiol       Date:  2003-06       Impact factor: 1.976

9.  Initial Experience With Ultra High-Density Mapping of Human Right Atria.

Authors:  Andreas Bollmann; Sebastian Hilbert; Silke John; Jedrzej Kosiuk; Gerhard Hindricks
Journal:  J Cardiovasc Electrophysiol       Date:  2015-11-23

10.  Pulmonary vein reconnection and arrhythmia progression after antral linear catheter ablation of paroxysmal and persistent atrial fibrillation.

Authors:  Kristina Wasmer; Dirk G Dechering; Julia Köbe; Gerold Mönnig; Christian Pott; Gerrit Frommeyer; Philipp S Lange; Simon Kochhäuser; Lars Eckardt
Journal:  Clin Res Cardiol       Date:  2016-04-05       Impact factor: 5.460

View more
  4 in total

1.  Successful localization and ablation of a Mahaim potential using a high-resolution mapping catheter after a failed conventional ablation attempt.

Authors:  Patrick Lugenbiel; Panagiotis Xynogalos; Patrick Schweizer; Hugo A Katus; Dierk Thomas; Eberhard P Scholz
Journal:  Clin Res Cardiol       Date:  2018-03-12       Impact factor: 5.460

2.  Catheter ablation of paroxysmal atrial fibrillation: circumferential pulmonary vein ablation: success rates with and without exclusion of areas adjacent to the esophagus.

Authors:  Klaus Kettering; Dag-Hau Yim; Alexander Benz; Felix Gramley
Journal:  Clin Res Cardiol       Date:  2017-05-10       Impact factor: 5.460

Review 3.  [High-resolution 3D mapping : Opportunities and limitations of the Rhythmia™ mapping system].

Authors:  Christian Ellermann; Gerrit Frommeyer; Lars Eckardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-07-17

4.  Acute safety, effectiveness, and real-world clinical usage of ultra-high density mapping for ablation of cardiac arrhythmias: results of the TRUE HD study.

Authors:  Gerhard Hindricks; Stanislav Weiner; Tom McElderry; Pierre Jaïs; William Maddox; Jose Ignacio Garcia-Bolao; Sang Yong Ji; Frederic Sacher; Stephan Willems; John Mounsey; Philippe Maury; Andreas Bollmann; Elizabeth Duffy; Giovanni Raciti; Roderick Tung; Tom Wong
Journal:  Europace       Date:  2019-04-01       Impact factor: 5.214

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.