Literature DB >> 21098450

Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up.

Feifan Ouyang1, Roland Tilz, Julian Chun, Boris Schmidt, Erik Wissner, Thomas Zerm, Kars Neven, Bulent Köktürk, Melanie Konstantinidou, Andreas Metzner, Alexander Fuernkranz, Karl-Heinz Kuck.   

Abstract

BACKGROUND: Paroxysmal atrial fibrillation (AF) naturally progresses toward chronic AF at an estimated rate of 15% to 30% over a 1- to 3-year period. Pulmonary vein (PV) isolation is increasingly performed for the treatment of drug-refractory paroxysmal AF. The long-term data on clinical outcome after circumferential PV isolation are limited. METHODS AND
RESULTS: From 2003 to late 2004, 161 patients (121 men; age, 59.8±9.7 years) with symptomatic paroxysmal AF and normal left ventricular function underwent circumferential PV isolation guided by 3-dimensional mapping and double Lasso technique. Right-sided and left-sided continuous circular lesions encircling the ipsilateral PVs were placed with irrigated radiofrequency energy. The procedure end point was the absence of all PV spikes for at least 30 minutes after PV isolation verified by 2 Lasso catheters placed within the ipsilateral PVs. Sinus rhythm was present in 75 patients (46.6%) after the initial procedure during a median follow-up period of 4.8 years (0.33 to 5.5 years). A second procedure was performed in 66 and a third procedure in 12 patients. Recovered PV isolation conduction was observed in 62 of 66 patients (94.0%) during the second and in 8 of 12 patients (66.7%) during the third procedure. After a median of 1 (1 to 3) procedure, stable sinus rhythm was achieved in 128 of 161 patients (79.5%), whereas clinical improvement occurred in an additional 21 of 161 patients (13.0%) during a median follow-up of 4.6 years (0.33 to 5.5 years). Four patients in stable sinus rhythm died during follow-up. Progression toward chronic AF was observed in 4 patients (2.4%); however, only 2 patients reported symptoms.
CONCLUSION: In patients with paroxysmal AF and normal left ventricular function, circumferential PV isolation results in stable sinus rhythm in the majority of patients, and low incidence of chronic AF was observed after ablation during up to 5 years of follow-up.

Entities:  

Mesh:

Year:  2010        PMID: 21098450     DOI: 10.1161/CIRCULATIONAHA.110.946806

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  156 in total

1.  The importance of catheter stability evaluated by Visitag(TM) during pulmonary vein isolation.

Authors:  Ryudo Fujiwara; Kimitake Imamura; Yoichi Kijima; Tomoya Masano; Ryoji Nagoshi; Amane Kohzuki; Hiroyuki Shibata; Yoshiro Tsukiyama; Ryo Takeshige; Kenichi Yanaka; Shinsuke Nakano; Yusuke Fukuyama; Junya Shite
Journal:  J Interv Card Electrophysiol       Date:  2016-01-19       Impact factor: 1.900

2.  THERMOCOOL® SMARTTOUCH® CATHETER - The Evidence So Far for Contact Force Technology and the Role of VISITAG™ MODULE.

Authors:  Tina Lin; Feifan Ouyang; Karl-Heinz Kuck; Roland Tilz
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-05-30

3.  Treatment Complications of Atrial Fibrillation and Their Management.

Authors:  Allan Mattia; Joshua Newman; Frank Manetta
Journal:  Int J Angiol       Date:  2020-03-05

4.  Lights on! Can visual light help distinguish fibrotic scars from ablation lesions?

Authors:  Anuradha Kalyanasundaram; Vadim V Fedorov
Journal:  Heart Rhythm       Date:  2018-01-05       Impact factor: 6.343

5.  Left atrial wall thickness and outcomes of catheter ablation for atrial fibrillation in patients with hypertrophic cardiomyopathy.

Authors:  Hiroshi Hayashi; Meiso Hayashi; Yasushi Miyauchi; Kenta Takahashi; Shunsuke Uetake; Ippei Tsuboi; Kenji Yodogawa; Yu-Ki Iwasaki; Wataru Shimizu
Journal:  J Interv Card Electrophysiol       Date:  2014-04-25       Impact factor: 1.900

6.  Randomized comparison of contact force-guided versus conventional circumferential pulmonary vein isolation of atrial fibrillation: prevalence, characteristics, and predictors of electrical reconnections and clinical outcomes.

Authors:  Kohki Nakamura; Shigeto Naito; Takehito Sasaki; Masahiro Nakano; Kentaro Minami; Yosuke Nakatani; Kentaro Ikeda; Eiji Yamashita; Koji Kumagai; Nobusada Funabashi; Shigeru Oshima
Journal:  J Interv Card Electrophysiol       Date:  2015-09-19       Impact factor: 1.900

Review 7.  [Radiofrequency current or cryoballoon for ablation of atrial fibrillation? : Hot or cold?]

Authors:  B Reissmann; K-H Kuck; A Metzner
Journal:  Herz       Date:  2017-06       Impact factor: 1.443

8.  [Catheter ablation of paroxysmal atrial fibrillation. Optimal approach and result].

Authors:  Shibu Mathew; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck; Roland Richard Tilz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-04-16

Review 9.  Making better scar: Emerging approaches for modifying mechanical and electrical properties following infarction and ablation.

Authors:  Jeffrey W Holmes; Zachary Laksman; Lior Gepstein
Journal:  Prog Biophys Mol Biol       Date:  2015-11-23       Impact factor: 3.667

Review 10.  New approaches to managing nonvalvular atrial fibrillation: what are the thromboembolic implications?

Authors:  Peter J Kudenchuk
Journal:  J Thromb Thrombolysis       Date:  2015-04       Impact factor: 2.300

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.