Literature DB >> 27848100

Stress distribution difference between Lava Ultimate full crowns and IPS e.max CAD full crowns on a natural tooth and on tooth-shaped implant abutments.

Ivo Krejci1, René Daher2.   

Abstract

The goal of this short communication is to present finite element analysis comparison of the stress distribution between CAD/CAM full crowns made of Lava Ultimate and of IPS e.max CAD, adhesively luted to natural teeth and to implant abutments with the shape of natural teeth. Six 3D models were prepared using a 3D content-creating software, based on a micro-CT scan of a human mandibular molar. The geometry of the full crown and of the abutment was the same for all models representing Lava Ultimate full crowns (L) and IPS e.max CAD full crowns (E) on three different abutments: prepared natural tooth (n), titanium abutment (t) and zirconia abutment (z). A static load of 400 N was applied on the vestibular and lingual cusps, and fixtures were applied to the base of the models. After running the static linear analysis, the post-processing data we analyzed. The stress values at the interface between the crown and the abutment of the Lt and Lz groups were significantly higher than the stress values at the same interface of all the other models. The high stress concentration in the adhesive at the interface between the crown and the abutment of the Lava Ultimate group on implants might be one of the factors contributing to the reported debondings of crowns.

Entities:  

Keywords:  Adhesively luted crown; Debonding; Implant abutment

Mesh:

Substances:

Year:  2016        PMID: 27848100     DOI: 10.1007/s10266-016-0276-z

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  4 in total

1.  Young's modulus of peritubular and intertubular human dentin by nano-indentation tests.

Authors:  Daniel Ziskind; Moran Hasday; Sidney R Cohen; H Daniel Wagner
Journal:  J Struct Biol       Date:  2010-09-17       Impact factor: 2.867

Review 2.  Mechanical biocompatibilities of titanium alloys for biomedical applications.

Authors:  Mitsuo Niinomi
Journal:  J Mech Behav Biomed Mater       Date:  2007-08-27

3.  The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses.

Authors:  Chenfeng Chen; Flávia Zardo Trindade; Niek de Jager; Cornelis J Kleverlaan; Albert J Feilzer
Journal:  Dent Mater       Date:  2014-07-15       Impact factor: 5.304

Review 4.  Zirconia as a ceramic biomaterial.

Authors:  C Piconi; G Maccauro
Journal:  Biomaterials       Date:  1999-01       Impact factor: 12.479

  4 in total
  6 in total

1.  Microleakage of composite crowns luted on CAD/CAM-milled human molars: a new method for standardized in vitro tests.

Authors:  Maximiliane Amelie Schlenz; Alexander Schmidt; Peter Rehmann; Thomas Niem; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2018-04-24       Impact factor: 3.573

2.  Roughness, surface energy, and superficial damages of CAD/CAM materials after surface treatment.

Authors:  Thomas Strasser; Verena Preis; Michael Behr; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-02-05       Impact factor: 3.573

3.  Retention of CAD/CAM resin composite crowns following different bonding protocols.

Authors:  Amir H Nejat; Jinwhan Lee; Shreya Shah; Chee Paul Lin; Prajakta Kulkarni; Ramakiran Chavali; Nathaniel C Lawson
Journal:  Am J Dent       Date:  2018-04       Impact factor: 1.522

4.  Fracture load of CAD/CAM-fabricated and 3D-printed composite crowns as a function of material thickness.

Authors:  Moritz Zimmermann; Andreas Ender; Gustav Egli; Mutlu Özcan; Albert Mehl
Journal:  Clin Oral Investig       Date:  2018-10-27       Impact factor: 3.573

5.  Effect of Two Immediate Dentin Sealing Approaches on Bond Strength of Lava™ CAD/CAM Indirect Restoration.

Authors:  Hassan Faez Abdullah Gailani; Cristina Benavides-Reyes; María Victoria Bolaños-Carmona; Eva Rosel-Gallardo; Purificación González-Villafranca; Santiago González-López
Journal:  Materials (Basel)       Date:  2021-03-26       Impact factor: 3.623

Review 6.  Ceramic Materials and Technologies Applied to Digital Works in Implant-Supported Restorative Dentistry.

Authors:  Se-Wook Pyo; Dae-Joon Kim; Jung-Suk Han; In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.