Literature DB >> 29691662

Microleakage of composite crowns luted on CAD/CAM-milled human molars: a new method for standardized in vitro tests.

Maximiliane Amelie Schlenz1, Alexander Schmidt2, Peter Rehmann2, Thomas Niem2, Bernd Wöstmann2.   

Abstract

OBJECTIVES: To investigate debonding of full crowns made of CAD/CAM composites, CAD/CAM technology was applied to manufacture standardized test abutments to increase the reproducibility of human teeth used in in vitro studies.
MATERIALS AND METHODS: A virtual test abutment and the corresponding virtual crown were designed and two STL data sets were generated. Sixty-four human third molars and CAD/CAM blocks were milled using a CNC machine. Crowns of four different composite blocks (Lava Ultimate (LU), Brilliant Crios (BC), Cerasmart (CS), Experimental (EX)) were adhesively bonded with their corresponding luting system (LU: Scotchbond Universal/RelyX Ultimate; BC: One Coat 7 Universal/DuoCem; CS: G-PremioBond/G-Cem LinkForce; EX: Experimental-Bond/Experimental-Luting-Cement). Half of the specimens were chemical-cured (CC) and the others were light-cured (LC). Afterwards, specimens were artificially aged in a chewing simulator (WL-tec, 1 million cycles, 50-500 N, 2 Hz, 37 °C). Finally, a dye penetration test was used to detect debonding. For inspection, the specimens were sliced, and penetration depth was measured with a digital microscope. Data were analyzed with the Mann-Whitney U test.
RESULTS: No cases of total debonding were observed after cyclic loading. However, the LC specimens showed a significantly lower amount of leakage than the CC ones (p < 0.05). Furthermore, the CC specimens exhibited broad scattering. Only the LC-EX blocks showed no debonding. The CC-CS blocks showed the highest leakage and scattering of all tested specimens.
CONCLUSIONS: Natural human teeth can be manufactured by CAD/CAM technology in highly standardized test abutments for in vitro testing. For CAD/CAM composites, light curing should be performed. CLINICAL RELEVANCE: The success of a restoration depends on the long-term sealing ability of the luting materials, which avoids debonding along with microleakage. For CAD/CAM composites, separate light curing of the adhesive and luting composite is highly recommended.

Entities:  

Keywords:  Adhesive cementation; CAD/CAM; Composite; Debonding; Microleakage

Mesh:

Substances:

Year:  2018        PMID: 29691662     DOI: 10.1007/s00784-018-2460-8

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  25 in total

1.  Stress analysis of metal-free polymer crowns using the three-dimensional finite element method.

Authors:  T Nakamura; A Imanishi; H Kashima; T Ohyama; S Ishigaki
Journal:  Int J Prosthodont       Date:  2001 Sep-Oct       Impact factor: 1.681

2.  Combined effects of thermocycling and load-cycling on microleakage of computer-aided design/computer-assisted manufacture molar crowns.

Authors:  Amr Shebl Kassem; Osama Atta; Omar El-Mowafy
Journal:  Int J Prosthodont       Date:  2011 Jul-Aug       Impact factor: 1.681

3.  Comparison of Marginal Gap and Microleakage in Copy-Milled and Cad-Milled Zirconia Copings Bonded Using Light Cure and Chemical Cure Resin Bonding Systems.

Authors:  Manoj Shetty; S Rajalakshmi; D Krishna Prasad
Journal:  J Indian Prosthodont Soc       Date:  2014-04-23

4.  Mechanical properties of resin-ceramic CAD/CAM restorative materials.

Authors:  Abdallah Awada; Dan Nathanson
Journal:  J Prosthet Dent       Date:  2015-07-02       Impact factor: 3.426

5.  Evaluation of marginal and internal adaptation of hybrid and nanoceramic systems with microcomputed tomography: An in vitro study.

Authors:  Güler Yildirim; Ismail H Uzun; Ali Keles
Journal:  J Prosthet Dent       Date:  2017-01-12       Impact factor: 3.426

6.  Fracture strength of CAD/CAM composite and composite-ceramic occlusal veneers.

Authors:  Andrew C Johnson; Antheunis Versluis; Daranee Tantbirojn; Swati Ahuja
Journal:  J Prosthodont Res       Date:  2014-03-11       Impact factor: 4.642

7.  The Impact of Core/Veneer Thickness Ratio and Cyclic Loading on Fracture Resistance of Lithium Disilicate Crown.

Authors:  Noor Nawafleh; Muhanad M Hatamleh; Andreas Öchsner; Florian Mack
Journal:  J Prosthodont       Date:  2016-03-09       Impact factor: 2.752

Review 8.  From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

Authors:  A K Mainjot; N M Dupont; J C Oudkerk; T Y Dewael; M J Sadoun
Journal:  J Dent Res       Date:  2016-03-01       Impact factor: 6.116

9.  Influence of cementation technique on fracture strength and leakage of alumina all-ceramic crowns after cyclic loading.

Authors:  Markus B Blatz; Steven Oppes; Gerard Chiche; Stefan Holst; Avishai Sadan
Journal:  Quintessence Int       Date:  2008-01       Impact factor: 1.677

Review 10.  Correlation between clinical performance and degree of conversion of resin cements: a literature review.

Authors:  Grace De Souza; Roberto Ruggiero Braga; Paulo Francisco Cesar; Guilherme Carpena Lopes
Journal:  J Appl Oral Sci       Date:  2015 Jul-Aug       Impact factor: 2.698

View more
  1 in total

1.  Internal and Marginal Adaptation of Adhesive Resin Cements Used for Luting Inlay Restorations: An In Vitro Micro-CT Study.

Authors:  Linah M Ashy; Hanadi Marghalani
Journal:  Materials (Basel)       Date:  2022-09-05       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.