Corneal biomechanics after small-incision lenticule extraction versus Q-value-guided femtosecond laser-assisted in situ keratomileusis.

Jun Zhang1, Li Zheng1, Xia Zhao1, Yang Xu1, Shu Chen1.   

Abstract

PURPOSE: The aim of this study was to compare the changes in corneal biomechanical properties following small-incision lenticule extraction (SMILE) versus Q-value-guided femtosecond laser-assisted in situ keratomileusis (Q-FS-LASIK).
METHODS: In this prospective comparative study, patients with a sphere plus cylinder measurement of less than -10.00 D and cylinder measurement of less than -5.00 D were included in the study. A total of 160 patients (160 eyes) with myopia and myopic astigmatism were divided into the two groups, with 80 patients (80 eyes) allocated to SMILE and 80 patients (80 eyes) allocated to Q-FS-LASIK. Corneal hysteresis (CH) and the corneal resistance factor (CRF) were quantitatively assessed using the Ocular Response Analyzer (ORA) preoperatively and at 1 day, 2 weeks, and 1 and 3 months postoperatively.
RESULTS: Both types of surgery were associated with statistically significant decreases in CH and the CRF at postoperative day 1 (both P < 0.01). In both groups, the decreases subsequently stabilized with no further deteriorations compared to postoperative day 1 (P > 0.05). Both groups showed similar biomechanical changes at each time point (all P > 0.05).
CONCLUSIONS: Both SMILE and Q-FS-LASIK resulted in a decrease in CH and the CRF at postoperative 1 day, with the decreases stabilizing after this point. There were no significant differences between the short term effects of SMILE and Q-FS-LASIK on corneal biomechanical properties.

Entities:  

Keywords:  Biomechanical properties; Femtosecond; Q-value guided; Small incision

Year:  2016        PMID: 27830201      PMCID: PMC5093843          DOI: 10.1016/j.joco.2016.08.004

Source DB:  PubMed          Journal:  J Curr Ophthalmol        ISSN: 2452-2325


Introduction

With the rapid and extensive development of modern corneal refractive surgery, related technologies have been promoted, and new surgical procedures have been developed. Q-value–guided femtosecond laser-assisted in situ keratomileusis (Q-FS-LASIK) is a safe surgical procedure in which lower spherical aberration is introduced,1, 2, 3, 4 and has been a popular procedure for corneal refractive surgery. Small-incision lenticular extraction (SMILE) is a new kind of surgical procedure that avoids flap-related complications, and it is gaining more attention. Both procedures have performed well in studies in all measures of safety, efficacy, and predictability.6, 7, 8 Although some previous studies have compared corneal biomechanical properties after SMILE and LASIK, the results have been inconsistent.9, 10 The aim of this study was therefore to increase the sample number to provide a better frame of reference. In addition, and different from earlier research, we used Q-FS-LASIK, which has not previously been compared with SMILE. In the current study, we measured corneal hysteresis (CH) and the corneal resistance factor (CRF) and evaluated the changes in corneal biomechanical properties following surgery.

Methods

The study and data accumulation were carried out with approval from HangZhou Bright Vision Hospital Independent Ethics Committee. In this prospective, non-randomized study (patients were allocated to each surgery through their own wishes), 160 patients (160 eyes) with myopia or myopia astigmatism were treated with either SMILE or Q-FS-LASIK at HangZhou Bright Vision Hospital between January and November 2015. In patients in whom both eyes were eligible, one eye was randomly chosen for inclusion. All participants were informed about the risks and benefits of both procedures and provided written informed consent. Patient inclusion criteria included a sphere plus cylinder measurement of less than −10.00 D and a cylinder measurement of less than −5.00 D.

Preoperative assessments

Preoperative assessments included a complete medical and ophthalmologic history and a thorough ocular examination, including measurement of uncorrected visual acuity, manifest refraction, best corrected visual acuity, cycloplegic refraction, slit-lamp examination, axial length, gonioscopy, funduscopy, and intraocular pressure. In addition, corneal topography was obtained using a tomography instrument (Sirius; CSO, Florence, Italy).

Measurement of biomechanical parameters

CH and CRF were determined using the Ocular Response Analyzer (ORA, Technologies, Depew, NY, USA). The mean value of three measurements with high signal quality was used for statistical analysis. High signal quality was defined as a device waveform signal score, based on the composite index of five corneal deformation signals of more than 6.5. ORA measures two applanation points during a single process. The first applanation pressure point (P1) occurs as an air puff pushes the cornea inward, while the second applanation pressure point (P2) occurs as the cornea returns from the applanated state to normal. CH is defined as the difference between P1 and P2. CRF is defined as a linear function of these two pressures: CRF = k1 × (P1 – 0.7 × P2) + k2, where k1 and k2 are constants.

Surgical procedures

All surgical procedures were performed by a single surgeon (L.Z.). Routine disinfection and surface anesthesia were performed before surgery.

SMILE

A total of 80 eyes underwent SMILE (VisuMax; Carl Zeiss, Oberkochen, Germany). During the procedure, a cap of 120 μm, a single side-cut incision with a circumferential length of 2.0 mm at the 120-degree position, a side-cut angle of 90°, a 3 × 3 μm point spacing of the lens surface, a 2.5 × 2.5 μm point spacing of the lens side, and a 2 × 2 μm point spacing of the side cut were created. After a femtosecond laser scan, both the front and back surfaces of the lens were separated using a micro-separator. The free lens was then removed using micro-forceps.

Q-FS-LASIK

A total of 80 eyes underwent Q-FS-LASIK with the use of the FS200 femtosecond laser and EX500 excimer laser (both Alcon, Fort Worth, Texas, USA). During flap creation, settings were adjusted to achieve a thickness of 100 μm, side-cut angle of 90°, 8 × 8 μm point spacing of the flap, and 5 × 3 μm point spacing of the side cut. After a femtosecond laser scan, the corneal stroma was ablated with a 0.2 negative adjustment of the Q value (6 mm).

Postoperative care and follow-up

After surgery, fluorometholone 0.1% and bromfenac sodium 0.1% were immediately administered topically, levofloxacin 0.3% (Cravit; Santen, Osaka, Japan) was administered topically four times a day for 1 week, and fluorometholone 0.1% was administered topically six times a day for 3 weeks, after which the frequency was steadily tapered. Patients were followed up, and the ORA measurements were repeated at 1 day, 2 weeks, and 1 and 3 months postoperatively.

Statistical analysis

All statistical analyses were performed using SPSS 19.0 (SPSS Inc., Chicago, USA). Student's t test was used to compare preoperative patient demographics between the two groups. For the purpose of statistical comparisons, visual acuity measurements were converted to logarithm of the minimum angle of resolution (LogMAR) units. Repeated-measures analysis of variance was used to assess the means of CH and CRF at different examination points within and between each group. The means of CH and CRF pre- and postoperatively were confirmed to meet the homogeneity of variance, and Fisher's least significant difference (LSD) test was therefore used for multiple comparisons within each group. The means of CH and CRF pre- and postoperatively did not meet the assumption of sphericity, and multivariate statistical analysis and degree of freedom adjustment were therefore used for comparisons between each group. Pearson correlation coefficients were calculated to evaluate correlations between 3-month changes in CH and CRF and multiple variables, including spherical, cylinder, and optical zone measurements. The results are expressed as mean ± SD, and P values of <0.05 were considered statistically significant.

Results

The study enrolled 160 patients (160 eyes), with the patients divided into two equal groups. The preoperative patient demographics are summarized in Table 1. All operations were successful, and no serious complications or iatrogenic corneal ectasia were seen during the 3 months postoperatively.
Table 1

Preoperative patient demographics.

ParameterSMILEQ-FS-LASIKt valueP value
Spherical (D)−5.12 ± 1.62−4.87 ± 1.800.900.37
Cylinder (D)−0.77 ± 0.63−0.84 ± 0.76−0.680.50
BCVA−0.03 ± 0.06−0.03 ± 0.050.430.67
UCVA1.28 ± 0.271.22 ± 0.231.540.13
CCT (μm)550.80 ± 25.77547.06 ± 29.530.850.40
Optical zone (mm)6.43 ± 0.156.40 ± 0.170.970.33

Values are means ± standard deviations.

BCVA = best corrected visual acuity, CCT = central corneal thickness, UCVA = uncorrected visual acuity.

The corneal biomechanical parameters are summarized in Table 2. The changes in CH and CRF following SMILE and Q-FS-LASIK are shown in Fig. 1, Fig. 2, respectively.
Table 2

Corneal biomechanical parameters.

ParameterPreoperativePostoperative
F valueP value
1 day2 weeks1 month3 months
Corneal hysteresis (mm Hg)
 SMILE10.64 ± 1.097.91 ± 1.067.94 ± 1.088.00 ± 0.997.91 ± 0.92109.840.001
 Q-FS-LASIK10.83 ± 1.607.98 ± 1.178.07 ± 1.378.17 ± 1.318.00 ± 1.3266.380.001
Corneal resistance factor (mm Hg)
 SMILE10.54 ± 1.536.88 ± 1.477.01 ± 1.387.08 ± 1.347.07 ± 1.27102.300.001
 Q-FS-LASIK10.71 ± 1.746.85 ± 1.426.87 ± 1.456.88 ± 1.466.82 ± 1.40105.830.001

Values are means ± standard deviations.

Fig. 1

CH changes following SMILE and Q-FS-LASIK. Changes in corneal hysteresis (CH) over time. Bars represent standard deviations. The differences in CH between the SMILE and Q-FS-LASIK groups were not statistically significant.

Fig. 2

CRF changes following SMILE and Q-FS-LASIK. Changes in the corneal resistance factor (CRF) over time. Bars represent standard deviations. The differences in CRF between the SMILE and Q-FS-LASIK groups were not statistically significant.

In the SMILE group, the variation in CH was statistically significant (P < 0.001). Fisher's LSD test showed that CH at each postoperative time point was statistically significantly lower than the preoperative value (P < 0.001). However, the difference between each postoperative time point was not significant (Table 3).
Table 3

Multiple comparisons within SMILE group.

ParameterP value
Corneal hysteresis
 Preoperative1 day postoperative0.001
2 weeks postoperative0.001
1 month postoperative0.001
3 months postoperative0.001
 1 day postoperative2 weeks postoperative0.84
1 month postoperative0.60
3 months postoperative0.99
 2 weeks postoperative1 month postoperative0.74
3 months postoperative0.86
 1 month postoperative3 months postoperative0.61
Corneal resistance factor
 Preoperative1 day postoperative0.001
2 weeks postoperative0.001
1 month postoperative0.001
3 months postoperative0.001
 1 day postoperative2 weeks postoperative0.55
1 month postoperative0.37
3 months postoperative0.40
 2 weeks postoperative1 month postoperative0.77
3 months postoperative0.81
 1 month postoperative3 months postoperative0.96
The variation in CRF in the SMILE group was also statistically significant (P < 0.001). Fisher's LSD test showed that the CRF at each postoperative time point was statistically significantly lower than the preoperative value (P < 0.001). However, the difference between each postoperative time point was not significant (Table 3). In Q-FS-LASIK group, the variation in CH was again statistically significant (P < 0.001). Fisher's LSD test showed that CH at each postoperative time point was statistically significantly lower than the preoperative value (P < 0.001). However, the difference between each postoperative time point was not significant (Table 4).
Table 4

Multiple comparisons within Q-FS-LASIK group.

ParameterP value
Corneal hysteresis
 Preoperative1 day postoperative0.001
2 weeks postoperative0.001
1 month postoperative0.001
3 months postoperative0.001
 1 day postoperative2 weeks postoperative0.66
1 month postoperative0.37
3 months postoperative0.92
 2 weeks postoperative1 month postoperative0.65
3 months postoperative0.74
 1 month postoperative3 months postoperative0.43
Corneal resistance factor
 Preoperative1 day postoperative0.001
2 weeks postoperative0.001
1 month postoperative0.001
3 months postoperative0.001
 1 day postoperative2 weeks postoperative0.95
1 month postoperative0.90
3 months postoperative0.90
 2 weeks postoperative1 month postoperative0.94
3 months postoperative0.85
 1 month postoperative3 months postoperative0.80
The variation in the CRF in the Q-FS-LASIK group was also statistically significant (P < 0.001). Fisher's LSD test showed that the CRF at each postoperative time point was statistically significantly lower than the preoperative value (P < 0.001). However, the difference between each postoperative time point was not significant (Table 4). The differences in CH and CRF between the SMILE and Q-FS-LASIK groups were not statistically significant (P = 0.044 and P = 0.64, respectively). In the SMILE group, the 3-month changes in CH and CRF were correlated with spherical measurements only (P = 0.002 and P < 0.001, respectively) (Table 5, Fig. 3).
Table 5

Correlation analysis.

R valueP value
SMILE
 Change of Corneal hysteresisSpherical0.340.002
Cylinder−0.160.17
Optical zone−0.030.76
 Change of Corneal resistance factorSpherical0.390.001
Cylinder0.050.67
Optical zone−0.070.54
Q-FS-LASIK
 Change of Corneal hysteresisSpherical0.540.001
Cylinder0.030.82
Optical zone−0.090.43
 Change of Corneal resistance factorSpherical0.490.001
Cylinder0.170.13
Optical zone−0.130.27
Fig. 3

Correlation analysis within the SMILE group. Scatterplot showing the correlation of spherical measurements with the difference between pre-operation and 3-month CH and CRF following SMILE. The changes in CH and CRF were both positively correlated with spherical measurements.

In the Q-FS-LASIK group, the 3-month changes in CH and CRF were also correlated with spherical measurements only (both P < 0.001) (Table 5, Fig. 4).
Fig. 4

Correlation analysis within the Q-FS-LASIK group. Scatterplot showing the correlation of spherical measurements with the difference between pre-operation and 3-month CH and CRF following Q-FS-LASIK. The changes in CH and CRF were both positively correlated with spherical measurements.

Discussion

Q-FS-LASIK, which is safe and associated with low spherical aberrations, has been a popular procedure for corneal refractive surgery. SMILE is a new kind of surgical procedure that avoids flap-related complications and is gaining more attention. Since the first case of corneal ectasia following LASIK, published by Seiler et al, the biomechanical properties of the cornea have become an important indicator of safety13, 14, 15 and are attracting more consideration. The ORA, a dynamic bidirectional applanation device, has been used in corneal refractive surgery to calculate the values of CH and the CRF, allowing a quantitative description of the cornea's biomechanical properties by measuring, recording, and analyzing changes in corneal shape. CH represents the cornea's absorption ability against external energy, while the CRF is an indicator of the total reaction of the cornea, incorporating corneal elastic resistance. Both CH and the CRF, as inherent attributes of the cornea, can be used in the diagnosis of keratoconus. The results of this study suggest that the cornea's absorption ability against external energy and corneal elastic resistance decreased by day 1 postoperatively following both SMILE and Q-FS-LASIK. This shows that both procedures affect the cornea's biomechanical properties, especially in highly myopic patients in whom greater amounts of corneal tissue are removed. This also indirectly shows that CH and the CRF are inherent attributes of the cornea, and that postoperative healing and mild morphologic changes have little effect on them. Consistent with other studies, highly myopic patients have larger risk of corneal ectasia following LASIK.18, 19 Corneal biomechanical properties are also affected by other surgical parameters, in addition to the amount of corneal stroma removed. Kirwan and O'Keefe reported that the decrease in CH was not statistically significantly different after LASIK or laser-assisted subepithelial keratectomy. Wu et al reported that LASIK was associated with greater changes in corneal biomechanical properties than SMILE. Furthermore, Medeiros et al reported, using a porcine model, that CH and the CRF did not change significantly after the creation of a 100 mm thin flap, but significantly decreased after the creation of a 300 mm thick flap. In the current study, we also found that CH and the CRF were very stable at 1 day, 2 weeks, and 1 and 3 months postoperatively following both SMILE and Q-FS-LASIK. Furthermore, there were no significant differences in CH and the CRF between the two groups at any postoperative time point. We followed patients for 3 months, because it has been previously reported that there are no significant changes in biomechanical properties between 3 and 6 months. However, it is possible that further biomechanical changes might occur over time, and long-term follow-up studies are therefore required. The observations from our study have several limitations. First, the sample size of our study population was relatively modest. Second, other surgical procedures were not considered as an independent factor or control group. Third, the non-randomized method of treatment allocation resulted is a small imbalance in some baseline patient characteristics between both groups. Selected bias was at least partially offset by having each patient select surgical procedure, however it could not be completely ruled out. Fourth, the study follow-up was limited to 3 months, which does not rule out the possibility of subsequent regression. Further studies are needed to elucidate long-term biomechanical changes. In summary, both SMILE and Q-FS-LASIK were associated with decreases in corneal biomechanics. These changes were seen on postoperative day 1 and were approximately stable thereafter. In addition, there were no significant differences between SMILE and Q-FS-LASIK in their effects on the biomechanical properties of the cornea.
  22 in total

1.  Visual and refractive outcomes of femtosecond lenticule extraction and small-incision lenticule extraction for myopia.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Akihito Igarashi; Hidenaga Kobashi
Journal:  Am J Ophthalmol       Date:  2013-10-07       Impact factor: 5.258

2.  Postoperative changes in intraocular pressure and corneal biomechanical metrics Laser in situ keratomileusis versus laser-assisted subepithelial keratectomy.

Authors:  Mujtaba A Qazi; Jeff P Sanderson; Ashraf M Mahmoud; Eric Y Yoon; Cynthia J Roberts; Jay S Pepose
Journal:  J Cataract Refract Surg       Date:  2009-10       Impact factor: 3.351

3.  Comparative evaluation of higher-order aberrations and corneal asphericity between wavefront-guided and aspheric LASIK for myopia.

Authors:  Jawahar Lal Goyal; Arushi Garg; Ritu Arora; Parul Jain; Yashpal Goel
Journal:  J Refract Surg       Date:  2014-11       Impact factor: 3.573

4.  Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis.

Authors:  Di Wu; Yan Wang; Lin Zhang; Shengsheng Wei; Xin Tang
Journal:  J Cataract Refract Surg       Date:  2014-04-18       Impact factor: 3.351

5.  Comparison of corneal hysteresis and corneal resistance factor after small incision lenticule extraction and femtosecond laser-assisted LASIK: a prospective fellow eye study.

Authors:  Alper Agca; Engin Bilge Ozgurhan; Ahmet Demirok; Ercument Bozkurt; Ugur Celik; Abdullah Ozkaya; Ilker Cankaya; Omer Faruk Yilmaz
Journal:  Cont Lens Anterior Eye       Date:  2013-07-04       Impact factor: 3.077

6.  Q-factor customized ablation profile for the correction of myopic astigmatism.

Authors:  Tobias Koller; Hans Peter Iseli; Farhad Hafezi; Michael Mrochen; Theo Seiler
Journal:  J Cataract Refract Surg       Date:  2006-04       Impact factor: 3.351

7.  Control of Induced Spherical Aberration in Moderate Hyperopic LASIK by Customizing Corneal Asphericity.

Authors:  Alfredo Amigó; Sergio Bonaque-González; Eduardo Guerras-Valera
Journal:  J Refract Surg       Date:  2015-12       Impact factor: 3.573

8.  Corneal hysteresis using the Reichert ocular response analyser: findings pre- and post-LASIK and LASEK.

Authors:  Caitriona Kirwan; Michael O'Keefe
Journal:  Acta Ophthalmol       Date:  2007-09-21       Impact factor: 3.761

9.  Iatrogenic keratectasia after laser in situ keratomileusis.

Authors:  T Seiler; K Koufala; G Richter
Journal:  J Refract Surg       Date:  1998 May-Jun       Impact factor: 3.573

10.  Femtosecond laser versus mechanical microkeratome-assisted flap creation for LASIK: a prospective, randomized, paired-eye study.

Authors:  Bojan Pajic; Iraklis Vastardis; Brigitte Pajic-Eggspuehler; Zisis Gatzioufas; Farhad Hafezi
Journal:  Clin Ophthalmol       Date:  2014-09-22
View more
  7 in total

1.  Changes in corneal biomechanics during small-incision lenticule extraction (SMILE) and femtosecond-assisted laser in situ keratomileusis (FS-LASIK).

Authors:  Kaiwei Cao; Lina Liu; Ting Yu; Feng Chen; Ji Bai; Ting Liu
Journal:  Lasers Med Sci       Date:  2019-08-29       Impact factor: 3.161

2.  Quality of life after refractive surgery: ReLEx SMILE vs Femto-LASIK.

Authors:  Olga Aleksandrovna Klokova; Sergey Nikolaevich Sakhnov; Maria Sergeevna Geydenrikh; Roman Olegovich Damashauskas
Journal:  Clin Ophthalmol       Date:  2019-03-26

Review 3.  Complications of small incision lenticule extraction.

Authors:  Mohamed Ibrahime Asif; Rahul Kumar Bafna; Jodhbir Singh Mehta; Jagadesh Reddy; Jeewan Singh Titiyal; Prafulla K Maharana; Namrata Sharma
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

4.  Short term changes in corneal stress-strain index and other corneal biomechanical parameters post-laser in situ keratomileusis.

Authors:  Vaishal P Kenia; Raj V Kenia; Onkar H Pirdankar
Journal:  Indian J Ophthalmol       Date:  2021-10       Impact factor: 1.848

5.  Elliptical versus circular flap configuration in myopic eyes undergoing femtosecond laser in situ keratomileusis surgery: A contralateral eye study.

Authors:  Amit Gupta; Anchal Thakur; Suruchi Gupta; Chintan Malhotra; Ashish Kulshrestha; Tripti Choudhary
Journal:  Indian J Ophthalmol       Date:  2021-12       Impact factor: 1.848

6.  Corneal aberrations after small-incision lenticule extraction versus Q value-guided laser-assisted in situ keratomileusis.

Authors:  Jun Zhang; Li Zheng; Xia Zhao; Yi Sun; Wei Feng; Minhui Yuan
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

7.  Comparison of changes in refractive error and corneal curvature following small-incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis surgery.

Authors:  Ya L Zhang; Li J Cao; Hong W Chen; Xiang H Xu; Zhao N Li; Lei Liu
Journal:  Indian J Ophthalmol       Date:  2018-11       Impact factor: 1.848

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.