Literature DB >> 27817149

Individualized correction of insulin measurement in hemolyzed serum samples.

Zhi-Qi Wu1, Ju Lu1, Huanhuan Chen1, Wensen Chen2, Hua-Guo Xu3.   

Abstract

Insulin measurement plays a key role in the investigation of patients with hypoglycemia, subtype classification of diabetes mellitus, insulin resistance, and impaired beta cell function. However, even slight hemolysis can negatively affect insulin measurement due to RBC insulin-degrading enzyme (IDE). Here, we derived and validated an individualized correction equation in an attempt to eliminate the effects of hemolysis on insulin measurement. The effects of hemolysis on insulin measurement were studied by adding lysed self-RBCs to serum. A correction equation was derived, accounting for both percentage and exposure time of hemolysis. The performance of this individualized correction was evaluated in intentionally hemolyzed samples. Insulin concentration decreased with increasing percentage and exposure time of hemolysis. Based on the effects of hemolysis on insulin measurement of 17 donors (baseline insulin concentrations ranged from 156 to 2119 pmol/L), the individualized hemolysis correction equation was derived: INScorr = INSmeas/(0.705lgHbplasma/Hbserum - 0.001Time - 0.612). This equation can revert insulin concentrations of the intentionally hemolyzed samples to values that were statistically not different from the corresponding insulin baseline concentrations (p = 0.1564). Hemolysis could lead to a negative interference on insulin measurement; by individualized hemolysis correction equation for insulin measurement, we can correct and report reliable serum insulin results for a wide range of degrees of sample hemolysis. This correction would increase diagnostic accuracy, reduce inappropriate therapeutic decisions, and improve patient satisfaction with care.

Entities:  

Keywords:  Hemolysis; Hypoglycemia; Individualized correction; Insulin; Pre-analytical

Mesh:

Substances:

Year:  2017        PMID: 27817149     DOI: 10.1007/s12026-016-8878-7

Source DB:  PubMed          Journal:  Immunol Res        ISSN: 0257-277X            Impact factor:   2.829


  10 in total

1.  Best practice No 173: clinical and laboratory investigation of adult spontaneous hypoglycaemia.

Authors:  R Gama; J D Teale; V Marks
Journal:  J Clin Pathol       Date:  2003-09       Impact factor: 3.411

2.  Insulin measurements in haemolysed serum: influence of insulinase inhibitors.

Authors:  R Sapin; J C Ongagna; F Gasser; D Grucker
Journal:  Clin Chim Acta       Date:  1998-06-08       Impact factor: 3.786

3.  Effect of hemolysis on the concentration of insulin in serum determined by RIA and IRMA.

Authors:  D Chevenne; A Letailleur; F Trivin; D Porquet
Journal:  Clin Chem       Date:  1998-02       Impact factor: 8.327

4.  Hemolysis is a major cause of variability in insulin measurement during oral glucose tolerance test in children.

Authors:  Giorgio Bellomo; Maria Giovanna Sulas; Elisabetta Mairate; Maria Beatrice Bardone; Roberta Rolla
Journal:  Clin Lab       Date:  2012       Impact factor: 1.138

5.  Haemolysis affects insulin but not C-peptide immunoassay.

Authors:  S O'Rahilly; M A Burnett; R F Smith; J H Darley; R C Turner
Journal:  Diabetologia       Date:  1987-06       Impact factor: 10.122

6.  Differential interferences of hemoglobin and hemolysis on insulin assay with the Abbott Architect-Ci8200 immunoassay.

Authors:  Simon Garinet; Soraya Fellahi; Ginette Marlin; Jacqueline Capeau; Guillaume Lefèvre; Jean-Philippe Bastard
Journal:  Clin Biochem       Date:  2014-01-31       Impact factor: 3.281

7.  Effect of hemolysis on insulin determination by the Beckman Coulter Unicell DXI 800 immunoassay analyzer.

Authors:  Paul R Cook; Christine Glenn; Annie Armston
Journal:  Clin Biochem       Date:  2010-01-18       Impact factor: 3.281

8.  Evaluation of immunochemiluminometric assays for the measurement of insulin and C-peptide using the ADVIA Centaur.

Authors:  Hanane El Kenz; Pierre Bergmann
Journal:  Clin Lab       Date:  2004       Impact factor: 1.138

9.  Evaluation and management of adult hypoglycemic disorders: an Endocrine Society Clinical Practice Guideline.

Authors:  Philip E Cryer; Lloyd Axelrod; Ashley B Grossman; Simon R Heller; Victor M Montori; Elizabeth R Seaquist; F John Service
Journal:  J Clin Endocrinol Metab       Date:  2008-12-16       Impact factor: 5.958

10.  Individualized correction of neuron-specific enolase (NSE) measurement in hemolyzed serum samples.

Authors:  Nicole V Tolan; Noemi Vidal-Folch; Alicia Algeciras-Schimnich; Ravinder J Singh; Stefan K G Grebe
Journal:  Clin Chim Acta       Date:  2013-06-15       Impact factor: 3.786

  10 in total
  1 in total

1.  A simple formula to correct for the effects of storage time and temperature on the insulin concentration.

Authors:  Xiaoli Zeng; Qi Chen; Guozhong Gong; Fangyuan Yuan; Ting Wang; Guoyuan Zhang; Xiaoping Li; Dongsheng Wang; Qiang Wang
Journal:  J Clin Lab Anal       Date:  2020-03-04       Impact factor: 2.352

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.