Literature DB >> 2778695

Measurement of postoperative intraocular lens tilting and decentration using Scheimpflug images.

K Sasaki1, Y Sakamoto, T Shibata, H Nakaizumi, Y Emori.   

Abstract

A three-dimensional, in vivo method for determining the position of implanted intraocular lenses (IOLs) using an image-processing technique has been developed. Two images of the anterior segment of the eye with an implanted IOL were photographed with a Scheimpflug camera at slit-lamp angles of 90 degrees and 180 degrees. After geometrical correction, the contours of the original images were enhanced using binarization and curve-fitting techniques. These images afforded calculation of the angle of tilt of the IOL optic axis relative to a standard reference line which connected the center of anterior corneal surface curvature with the geometrical center of the pupil. The extent and direction of IOL decentration could also be shown. The IOL image in the posterior chamber was expressed as a wire-frame figure. This method provides several kinds of biometry in pseudophakic eyes.

Entities:  

Mesh:

Year:  1989        PMID: 2778695     DOI: 10.1016/s0886-3350(89)80071-9

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration.

Authors:  T Oshika; G Sugita; K Miyata; T Tokunaga; T Samejima; C Okamoto; Y Ishii
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

2.  Femtosecond laser-assisted cataract surgery versus conventional phacoemulsification: comparison of internal aberrations and visual quality.

Authors:  Yueyang Zhong; Yanan Zhu; Wei Wang; Kai Wang; Xin Liu; Ke Yao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-10-12       Impact factor: 3.117

3.  A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.

Authors:  R Nejima; K Miyata; M Honbou; T Tokunaga; T Tanabe; M Sato; T Oshika
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

4.  Tilt, Decentration, and Internal Higher-Order Aberrations of Sutured Posterior-Chamber Intraocular Lenses in Patients with Open Globe Injuries.

Authors:  Xiangjia Zhu; Yinglei Zhang; Wenwen He; Hongfei Ye; Chunhui Jiang; Yi Lu
Journal:  J Ophthalmol       Date:  2017-10-29       Impact factor: 1.909

Review 5.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.