Literature DB >> 2778144

Proton MR chemical shift imaging using double and triple phase contrast acquisition methods.

C C Lodes1, J P Felmlee, R L Ehman, C M Sehgal, J F Greenleaf, G H Glover, J E Gray.   

Abstract

Conventional chemical shift magnetic resonance (MR) imaging with the phase contrast technique has a number of limitations with respect to quantitative accuracy. The hypothesis of this study is that the accuracy of phase contrast chemical shift MR may be improved by increasing the number of basis images from two to three. Water and fat images were obtained from phantoms and volunteers with a 1.5 T MR system using double and triple acquisition phase contrast chemical shift methods. Longitudinal relaxation time and relative water and fat content were calculated from these basis images. The T1 relaxation times of the aqueous component of composite phantoms were determined more accurately using the triple acquisition method than with the double acquisition method. In vivo studies demonstrate that the triple acquisition method separated fat and water signals more accurately and showed less field inhomogeneity dependence than the modified double acquisition method. The new method also provided a map of static field magnetic inhomogeneity and tissue magnetic susceptibility. The triple acquisition phase contrast chemical shift imaging technique should improve the prospect for quantitative tissue characterization in clinical MR.

Entities:  

Mesh:

Year:  1989        PMID: 2778144     DOI: 10.1097/00004728-198909000-00020

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  9 in total

1.  Post-processing water-fat imaging technique for fat suppression in a low-field MR imaging system, evaluation in patients with rheumatoid arthritis.

Authors:  Kari Palosaari; Osmo Tervonen
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Comparative MR study of hepatic fat quantification using single-voxel proton spectroscopy, two-point dixon and three-point IDEAL.

Authors:  Hyeonjin Kim; Sara E Taksali; Sylvie Dufour; Douglas Befroy; T Robin Goodman; Kitt Falk Petersen; Gerald I Shulman; Sonia Caprio; R Todd Constable
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

Review 3.  Liver fat content determined by magnetic resonance imaging and spectroscopy.

Authors:  Fabian Springer; Jürgen Machann; Claus D Claussen; Fritz Schick; Nina F Schwenzer
Journal:  World J Gastroenterol       Date:  2010-04-07       Impact factor: 5.742

4.  Three-point Dixon method with a MISSTEC sequence.

Authors:  F Lethimonnier; F Franconi; S Akoka
Journal:  MAGMA       Date:  1997-12       Impact factor: 2.310

5.  Accurate and simple method for quantification of hepatic fat content using magnetic resonance imaging: a prospective study in biopsy-proven nonalcoholic fatty liver disease.

Authors:  Tomoko Hatta; Yasunari Fujinaga; Masumi Kadoya; Hitoshi Ueda; Hiroaki Murayama; Masahiro Kurozumi; Kazuhiko Ueda; Michiharu Komatsu; Tadanobu Nagaya; Satoru Joshita; Ryo Kodama; Eiji Tanaka; Tsuyoshi Uehara; Kenji Sano; Naoki Tanaka
Journal:  J Gastroenterol       Date:  2010-07-13       Impact factor: 7.527

6.  ISMRM workshop on fat-water separation: insights, applications and progress in MRI.

Authors:  Houchun Harry Hu; Peter Börnert; Diego Hernando; Peter Kellman; Jingfei Ma; Scott Reeder; Claude Sirlin
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

7.  Time-resolved contrast-enhanced MR angiography with single-echo Dixon fat suppression.

Authors:  Eric G Stinson; Joshua D Trzasko; Norbert G Campeau; James F Glockner; John Huston; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2018-02-27       Impact factor: 4.668

8.  Comparative accuracy of CT, dual-echo MRI and MR spectroscopy for preoperative liver fat quantification in living related liver donors.

Authors:  Ruchi Rastogi; Subhash Gupta; Bhavya Garg; Sandeep Vohra; Manav Wadhawan; Harsh Rastogi
Journal:  Indian J Radiol Imaging       Date:  2016 Jan-Mar

9.  Dual echo Dixon imaging with a constrained phase signal model and graph cuts reconstruction.

Authors:  Eric G Stinson; Joshua D Trzasko; Joel G Fletcher; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2017-02-02       Impact factor: 4.668

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.