Literature DB >> 2777280

Electrode models for electric current computed tomography.

K S Cheng, D Isaacson, J C Newell, D G Gisser.   

Abstract

This paper develops a mathematical model for the physical properties of electrodes suitable for use in electric current computed tomography (ECCT). The model includes the effects of discretization, shunt, and contact impedance. The complete model was validated by experiment. Bath resistivities of 284.0, 139.7, 62.3, 29.5 omega.cm were studied. Values of "effective" contact impedance zeta used in the numerical approximations were 58.0, 35.0, 15.0, and 7.5 omega.cm2, respectively. Agreement between the calculated and experimentally measured values was excellent throughout the range of bath conductivities studied. It is desirable in electrical impedance imaging systems to model the observed voltages to the same precision as they are measured in order to be able to make the highest resolution reconstructions of the internal conductivity that the measurement precision allows. The complete electrode model, which includes the effects of discretization of the current pattern, the shunt effect due to the highly conductive electrode material, and the effect of an "effective" contact impedance, allows calculation of the voltages due to any current pattern applied to a homogeneous resistivity field.

Mesh:

Year:  1989        PMID: 2777280      PMCID: PMC4816634          DOI: 10.1109/10.35300

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  Electrical properties of the epidermal stratum corneum.

Authors:  T Yamamoto; Y Yamamoto
Journal:  Med Biol Eng       Date:  1976-03

2.  Skin impedance from 1 Hz to 1 MHz.

Authors:  J Rosell; J Colominas; P Riu; R Pallas-Areny; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1988-08       Impact factor: 4.538

3.  Theory and performance of an adaptive current tomography system.

Authors:  D G Gisser; D Isaacson; J C Newell
Journal:  Clin Phys Physiol Meas       Date:  1988

4.  Computation of the impedance characteristic of metal electrodes for biological investigations.

Authors:  V Pollak
Journal:  Med Biol Eng       Date:  1974-07

5.  The impedance of stainless-steel electrodes.

Authors:  L A Geddes; C P Da Costa; G Wise
Journal:  Med Biol Eng       Date:  1971-09

6.  Current topics in impedance imaging.

Authors:  D G Gisser; D Isaacson; J C Newell
Journal:  Clin Phys Physiol Meas       Date:  1987
  6 in total
  38 in total

1.  A 3D reconstruction algorithm for EIT using a handheld probe for breast cancer detection.

Authors:  Tzu-Jen Kao; D Isaacson; J C Newell; G J Saulnier
Journal:  Physiol Meas       Date:  2006-04-18       Impact factor: 2.833

2.  Reducing boundary effects in static EIT imaging.

Authors:  Tzu-Jen Kao; Bong Seok Kim; D Isaacson; J C Newell; G J Saulnier
Journal:  Physiol Meas       Date:  2006-04-18       Impact factor: 2.833

3.  Dynamic electrical impedance imaging of a chest phantom using the Kalman filter.

Authors:  Bong Seok Kim; Kyung Youn Kim; Tzu-Jen Kao; Jonathan C Newell; David Isaacson; Gary J Saulnier
Journal:  Physiol Meas       Date:  2006-04-18       Impact factor: 2.833

4.  Design of electrodes and current limits for low frequency electrical impedance tomography of the brain.

Authors:  O Gilad; L Horesh; D S Holder
Journal:  Med Biol Eng Comput       Date:  2007-06-28       Impact factor: 2.602

5.  The complete electrode model for EIT in a mammography geometry.

Authors:  Bong Seok Kim; Gregory Boverman; Jonathan C Newell; Gary J Saulnier; David Isaacson
Journal:  Physiol Meas       Date:  2007-06-26       Impact factor: 2.833

6.  Reconstructions of conductive and insulating targets using the D-bar method on an elliptical domain.

Authors:  E K Murphy; J L Mueller; J C Newell
Journal:  Physiol Meas       Date:  2007-06-26       Impact factor: 2.833

7.  An implementation of CalderOn's method for 3-D limited-view EIT.

Authors:  Gregory Boverman; Tzu-Jen Kao; David Isaacson; Gary J Saulnier
Journal:  IEEE Trans Med Imaging       Date:  2009-01-19       Impact factor: 10.048

8.  Toward microendoscopic electrical impedance tomography for intraoperative surgical margin assessment.

Authors:  Ryan J Halter; Young-Joong Kim
Journal:  IEEE Trans Biomed Eng       Date:  2014-06-06       Impact factor: 4.538

9.  Estimating a regional ventilation-perfusion index.

Authors:  P A Muller; T Li; D Isaacson; J C Newell; G J Saulnier; Tzu-Jen Kao; Jeffrey Ashe
Journal:  Physiol Meas       Date:  2015-05-26       Impact factor: 2.833

10.  Robust linearized image reconstruction for multifrequency EIT of the breast.

Authors:  Gregory Boverman; Tzu-Jen Kao; Rujuta Kulkarni; Bong Seok Kim; David Isaacson; Gary J Saulnier; Jonathan C Newell
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.