Literature DB >> 19164077

An implementation of CalderOn's method for 3-D limited-view EIT.

Gregory Boverman1, Tzu-Jen Kao, David Isaacson, Gary J Saulnier.   

Abstract

Mathematical interest in electrical impedance tomography has been strong since the publication of CalderOn's foundational paper. This paper introduced the idea of applying external voltage patterns to a medium such that, assuming that the medium is sufficiently close to a constant admittivity, the reconstruction can be accomplished directly by inverse Fourier transform. Motivated by CalderOn's method, we have developed a variant of the algorithm which is applicable to the case of measurement on only a part of the boundary and on discrete electrodes. Here we determine voltage or current patterns to apply to the electrodes which optimally approximate CalderOn's special functions in the interior. Furthermore, in three dimensions and higher, CalderOn's method allows each point in Fourier space to be computed in a multiplicity of ways. We show that by making use of the inherent redundancy in our measurements, we can significantly improve the quality of the static images produced by our algorithm.

Entities:  

Mesh:

Year:  2009        PMID: 19164077      PMCID: PMC2724843          DOI: 10.1109/TMI.2009.2012892

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

1.  Three-dimensional electrical impedance tomography based on the complete electrode model.

Authors:  P J Vauhkonen; M Vauhkonen; T Savolainen; J P Kaipio
Journal:  IEEE Trans Biomed Eng       Date:  1999-09       Impact factor: 4.538

2.  A direct reconstruction algorithm for electrical impedance tomography.

Authors:  Jennifer L Mueller; Samuli Siltanen; David Isaacson
Journal:  IEEE Trans Med Imaging       Date:  2002-06       Impact factor: 10.048

3.  Reconstructions of chest phantoms by the D-bar method for electrical impedance tomography.

Authors:  David Isaacson; Jennifer L Mueller; Jonathan C Newell; Samuli Siltanen
Journal:  IEEE Trans Med Imaging       Date:  2004-07       Impact factor: 10.048

4.  The complete electrode model for EIT in a mammography geometry.

Authors:  Bong Seok Kim; Gregory Boverman; Jonathan C Newell; Gary J Saulnier; David Isaacson
Journal:  Physiol Meas       Date:  2007-06-26       Impact factor: 2.833

5.  An electrical impedance spectroscopy system for breast cancer detection.

Authors:  Gary J Saulnier; Ning Liu; Chandana Tamma; Hongjun Xia; Tzu-Jen Kao; J C Newell; David Isaacson
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

6.  The complete electrode model for imaging and electrode contact compensation in electrical impedance tomography.

Authors:  Gregory Boverman; Bong Seok Kim; David Isaacson; Jonathan C Newell
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

7.  Electrode models for electric current computed tomography.

Authors:  K S Cheng; D Isaacson; J C Newell; D G Gisser
Journal:  IEEE Trans Biomed Eng       Date:  1989-09       Impact factor: 4.538

8.  A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry.

Authors:  Myoung Hwan Choi; Tzu-Jen Kao; David Isaacson; Gary J Saulnier; Jonathan C Newell
Journal:  IEEE Trans Biomed Eng       Date:  2007-04       Impact factor: 4.538

9.  Robust linearized image reconstruction for multifrequency EIT of the breast.

Authors:  Gregory Boverman; Tzu-Jen Kao; Rujuta Kulkarni; Bong Seok Kim; David Isaacson; Gary J Saulnier; Jonathan C Newell
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

  9 in total
  4 in total

1.  Calderón's method on an elliptical domain.

Authors:  P A Muller; D Isaacson; J C Newell; G J Saulnier
Journal:  Physiol Meas       Date:  2013-05-29       Impact factor: 2.833

2.  The D-bar method for electrical impedance tomography-demystified.

Authors:  J L Mueller; S Siltanen
Journal:  Inverse Probl       Date:  2020-08-31       Impact factor: 2.407

3.  3D ELECTRICAL IMPEDANCE TOMOGRAPHY RECONSTRUCTIONS FROM SIMULATED ELECTRODE DATA USING DIRECT INVERSION texp AND CALDERÓN METHODS.

Authors:  S J Hamilton; D Isaacson; V Kolehmainen; P A Muller; J Toivanen; P F Bray
Journal:  Inverse Probl Imaging (Springfield)       Date:  2021-05-01       Impact factor: 1.639

4.  A Three Dimensional Calderon-Based Method for EIT on the Cylindrical Geometry.

Authors:  Kwancheol Shin; Sanwar Uddin Ahmad; Jennifer L Mueller
Journal:  IEEE Trans Biomed Eng       Date:  2021-04-21       Impact factor: 4.538

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.