Literature DB >> 27752404

Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

Lawrence Lechuga1, Georg A Weidlich2.   

Abstract

A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

Entities:  

Keywords:  cbct; dose; fan beam; fbct; image quality; uniformity

Year:  2016        PMID: 27752404      PMCID: PMC5063198          DOI: 10.7759/cureus.778

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  6 in total

1.  A (short) history of image-guided radiotherapy.

Authors:  Dirk Verellen; Mark De Ridder; Guy Storme
Journal:  Radiother Oncol       Date:  2008-01       Impact factor: 6.280

2.  Evaluation of image quality for different kV cone-beam CT acquisition and reconstruction methods in the head and neck region.

Authors:  Ulrik V Elstrøm; Ludvig P Muren; Jørgen B B Petersen; Cai Grau
Journal:  Acta Oncol       Date:  2011-08       Impact factor: 4.089

3.  The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential). Institution of Physics and Engineering in Medicine and Biology.

Authors: 
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

4.  Radiation dose from cone beam computed tomography for image-guided radiation therapy.

Authors:  Monica W K Kan; Lucullus H T Leung; Wicger Wong; Nelson Lam
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-05       Impact factor: 7.038

5.  Comparative evaluation of image quality from three CT simulation scanners.

Authors:  Claire McCann; Hamideh Alasti
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

6.  A study on image quality provided by a kilovoltage cone-beam computed tomography.

Authors:  Julia Garayoa; Pablo Castro
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

  6 in total
  23 in total

1.  Cluster signal-to-noise analysis for evaluation of the information content in an image.

Authors:  Warangkana Weerawanich; Mayumi Shimizu; Yohei Takeshita; Kazutoshi Okamura; Shoko Yoshida; Kazunori Yoshiura
Journal:  Dentomaxillofac Radiol       Date:  2017-12-11       Impact factor: 2.419

2.  Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review.

Authors:  Anne T Davis; Antony L Palmer; Andrew Nisbet
Journal:  Br J Radiol       Date:  2017-05-23       Impact factor: 3.039

Review 3.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

4.  Electronic processing of digital panoramic radiography for the detection of apical periodontitis.

Authors:  Cosimo Nardi; Linda Calistri; Michele Pietragalla; Chiara Vignoli; Chiara Lorini; Valentina Berti; Francesco Mungai; Stefano Colagrande
Journal:  Radiol Med       Date:  2019-11-07       Impact factor: 3.469

Review 5.  The role of radiomics in prostate cancer radiotherapy.

Authors:  Rodrigo Delgadillo; John C Ford; Matthew C Abramowitz; Alan Dal Pra; Alan Pollack; Radka Stoyanova
Journal:  Strahlenther Onkol       Date:  2020-08-21       Impact factor: 3.621

Review 6.  Upper airway visualization in pediatric obstructive sleep apnea.

Authors:  Courtney M Quinlan; Hansel Otero; Ignacio E Tapia
Journal:  Paediatr Respir Rev       Date:  2019-04-04       Impact factor: 2.726

7.  Image Guidance in Spinal Surgery: A Critical Appraisal and Future Directions.

Authors:  Fabian Sommer; Jacob L Goldberg; Lynn McGrath; Sertac Kirnaz; Branden Medary; Roger Härtl
Journal:  Int J Spine Surg       Date:  2021-10

Review 8.  Weight-bearing cone-beam computed tomography in the foot and ankle specialty: where we are and where we are going - an update.

Authors:  Alexandre Leme Godoy-Santos; Alessio Bernasconi; Marcelo Bordalo-Rodrigues; François Lintz; Carlos Felipe Teixeira Lôbo; Cesar de Cesar Netto
Journal:  Radiol Bras       Date:  2021 May-Jun

9.  CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy.

Authors:  Min Cheol Jeon; Ju Ock Kim; Sung Soo Jung; Hee Sun Park; Jeong Eun Lee; Jae Young Moon; Chae Uk Chung; Da Hyun Kang; Dong Il Park
Journal:  Tuberc Respir Dis (Seoul)       Date:  2018-06-19

10.  A study on the association between accessory maxillary ostium and maxillary sinus mucosal thickening using cone beam computed tomography.

Authors:  Shishir Shetty; Saad Wahby Al Bayatti; Natheer Hashim Al-Rawi; Rani Samsudin; Hesham Marei; Raghavendra Shetty; Hossam Abdelatty Abdelmagyd; Sesha Reddy
Journal:  Head Face Med       Date:  2021-07-14       Impact factor: 2.151

View more