Literature DB >> 27723609

Illumination Variation-Resistant Video-Based Heart Rate Measurement Using Joint Blind Source Separation and Ensemble Empirical Mode Decomposition.

Juan Cheng, Xun Chen, Lingxi Xu, Z Jane Wang.   

Abstract

Recent studies have demonstrated that heart rate (HR) could be estimated using video data [e.g., exploring human facial regions of interest (ROIs)] under well-controlled conditions. However, in practice, the pulse signals may be contaminated by motions and illumination variations. In this paper, tackling the illumination variation challenge, we propose an illumination-robust framework using joint blind source separation (JBSS) and ensemble empirical mode decomposition (EEMD) to effectively evaluate HR from webcam videos. The framework takes the hypotheses that both facial ROI and background ROI have similar illumination variations. The background ROI is then considered as a noise reference sensor to denoise the facial signals by using the JBSS technique to extract the underlying illumination variation sources. Further, the reconstructed illumination-resisted green channel of the facial ROI is detrended and decomposed into a number of intrinsic mode functions using EEMD to estimate the HR. Experimental results demonstrated that the proposed framework could estimate HR more accurately than the state-of-the-art methods. The Bland-Altman plots showed that it led to better agreement with HR ground truth with the mean bias 1.15 beats/min (bpm), with 95% limits from -15.43 to 17.73 bpm, and the correlation coefficient 0.53. This study provides a promising solution for realistic noncontact and robust HR measurement applications.

Entities:  

Mesh:

Year:  2016        PMID: 27723609     DOI: 10.1109/JBHI.2016.2615472

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  10 in total

1.  Bounded Kalman filter method for motion-robust, non-contact heart rate estimation.

Authors:  Sakthi Kumar Arul Prakash; Conrad S Tucker
Journal:  Biomed Opt Express       Date:  2018-01-29       Impact factor: 3.732

2.  Simultaneous Tracking of Cardiorespiratory Signals for Multiple Persons Using a Machine Vision System With Noise Artifact Removal.

Authors:  Ali Al-Naji; Javaan Chahl
Journal:  IEEE J Transl Eng Health Med       Date:  2017-09-29       Impact factor: 3.316

3.  Remote monitoring of cardiorespiratory signals from a hovering unmanned aerial vehicle.

Authors:  Ali Al-Naji; Asanka G Perera; Javaan Chahl
Journal:  Biomed Eng Online       Date:  2017-08-08       Impact factor: 2.819

Review 4.  Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review.

Authors:  Luwei Nie; Daniel Berckmans; Chaoyuan Wang; Baoming Li
Journal:  Sensors (Basel)       Date:  2020-04-17       Impact factor: 3.576

Review 5.  A Broader Look: Camera-Based Vital Sign Estimation across the Spectrum.

Authors:  Christoph Hoog Antink; Simon Lyra; Michael Paul; Xinchi Yu; Steffen Leonhardt
Journal:  Yearb Med Inform       Date:  2019-08-16

6.  Modelling and Validation of Computer Vision Techniques to Assess Heart Rate, Eye Temperature, Ear-Base Temperature and Respiration Rate in Cattle.

Authors:  Maria Jorquera-Chavez; Sigfredo Fuentes; Frank R Dunshea; Robyn D Warner; Tomas Poblete; Ellen C Jongman
Journal:  Animals (Basel)       Date:  2019-12-06       Impact factor: 2.752

7.  An iPPG-Based Device for Pervasive Monitoring of Multi-Dimensional Cardiovascular Hemodynamics.

Authors:  Jingjing Luo; Junjie Zhen; Peng Zhou; Wei Chen; Yuzhu Guo
Journal:  Sensors (Basel)       Date:  2021-01-28       Impact factor: 3.576

8.  Non-Contact Heart Rate Detection When Face Information Is Missing during Online Learning.

Authors:  Kun Zheng; Kangyi Ci; Jinling Cui; Jiangping Kong; Jing Zhou
Journal:  Sensors (Basel)       Date:  2020-12-08       Impact factor: 3.576

9.  Contactless facial video recording with deep learning models for the detection of atrial fibrillation.

Authors:  Yu Sun; Yin-Yin Yang; Bing-Jhang Wu; Po-Wei Huang; Shao-En Cheng; Bing-Fei Wu; Chun-Chang Chen
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.379

10.  Camera-based heart rate estimation for hospitalized newborns in the presence of motion artifacts.

Authors:  Qiong Chen; Yalin Wang; Xiangyu Liu; Xi Long; Bin Yin; Chen Chen; Wei Chen
Journal:  Biomed Eng Online       Date:  2021-12-04       Impact factor: 2.819

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.