Literature DB >> 29043113

Simultaneous Tracking of Cardiorespiratory Signals for Multiple Persons Using a Machine Vision System With Noise Artifact Removal.

Ali Al-Naji1,2, Javaan Chahl1,3.   

Abstract

Most existing non-contact monitoring systems are limited to detecting physiological signs from a single subject at a time. Still, another challenge facing these systems is that they are prone to noise artifacts resulting from motion of subjects, facial expressions, talking, skin tone, and illumination variations. This paper proposes an efficient non-contact system based on a digital camera to track the cardiorespiratory signal from a number of subjects (up to six persons) at the same time with a new method for noise artifact removal. The proposed system relied on the physiological and physical effects as a result of the activity of the cardiovascular and respiratory systems, such as skin color changes and head motion. Since these effects are imperceptible to the human eye and highly affected by the noise variations, we used advanced signal and video processing techniques, including developing video magnification technique, complete ensemble empirical mode decomposition with adaptive noise, and canonical correlation analysis to extract the heart rate and respiratory rate from multiple subjects under the noise artifact assumptions. The experimental results of the proposed system had a significant correlation (Pearson's correlation coefficient = 0.9994, Spearman correlation coefficient = 0.9987, and root mean square error = 0.32) when compared with the conventional contact methods (pulse oximeter and piezorespiratory belt), which makes the proposed system a promising candidate for novel applications.

Entities:  

Keywords:  Cardiorespiratory signal; camera imaging-based methods; canonical correlation analysis; complete ensemble EMD with adaptive noise; graphical user interface; imaging photoplethysmography (iPPG); video magnification technique

Year:  2017        PMID: 29043113      PMCID: PMC5642312          DOI: 10.1109/JTEHM.2017.2757485

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  32 in total

1.  Development of real-time image sequence analysis for evaluating posture change and respiratory rate of a subject in bed.

Authors:  K Nakajim; Y Matsumoto; T Tamura
Journal:  Physiol Meas       Date:  2001-08       Impact factor: 2.833

2.  Online removal of muscle artifact from electroencephalogram signals based on canonical correlation analysis.

Authors:  Junfeng Gao; Chongxun Zheng; Pei Wang
Journal:  Clin EEG Neurosci       Date:  2010-01       Impact factor: 1.843

3.  Canonical correlation analysis: an overview with application to learning methods.

Authors:  David R Hardoon; Sandor Szedmak; John Shawe-Taylor
Journal:  Neural Comput       Date:  2004-12       Impact factor: 2.026

4.  Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram.

Authors:  Wim De Clercq; Anneleen Vergult; Bart Vanrumste; Wim Van Paesschen; Sabine Van Huffel
Journal:  IEEE Trans Biomed Eng       Date:  2006-12       Impact factor: 4.538

5.  ECG signal denoising and baseline wander correction based on the empirical mode decomposition.

Authors:  Manuel Blanco-Velasco; Binwei Weng; Kenneth E Barner
Journal:  Comput Biol Med       Date:  2007-07-31       Impact factor: 4.589

6.  Remote sensing of physiological signs using a machine vision system.

Authors:  Ali Al-Naji; Kim Gibson; Javaan Chahl
Journal:  J Med Eng Technol       Date:  2017-04-27

7.  Algorithmic Principles of Remote PPG.

Authors:  Wenjin Wang; Albertus C den Brinker; Sander Stuijk; Gerard de Haan
Journal:  IEEE Trans Biomed Eng       Date:  2016-09-13       Impact factor: 4.538

8.  A novel method for extracting respiration rate and relative tidal volume from infrared thermography.

Authors:  Gregory F Lewis; Rodolfo G Gatto; Stephen W Porges
Journal:  Psychophysiology       Date:  2011-01-07       Impact factor: 4.016

9.  Noncontact respiratory measurement of volume change using depth camera.

Authors:  Meng-Chieh Yu; Jia-Ling Liou; Shuenn-Wen Kuo; Ming-Sui Lee; Yi-Ping Hung
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

10.  Remote monitoring of cardiorespiratory signals from a hovering unmanned aerial vehicle.

Authors:  Ali Al-Naji; Asanka G Perera; Javaan Chahl
Journal:  Biomed Eng Online       Date:  2017-08-08       Impact factor: 2.819

View more
  3 in total

1.  Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms.

Authors:  Sean Bae; Silviu Borac; Yunus Emre; Jonathan Wang; Jiang Wu; Mehr Kashyap; Si-Hyuck Kang; Liwen Chen; Melissa Moran; Julie Cannon; Eric S Teasley; Allen Chai; Yun Liu; Neal Wadhwa; Michael Krainin; Michael Rubinstein; Alejandra Maciel; Michael V McConnell; Shwetak Patel; Greg S Corrado; James A Taylor; Jiening Zhan; Ming Jack Po
Journal:  Commun Med (Lond)       Date:  2022-04-12

Review 2.  A Broader Look: Camera-Based Vital Sign Estimation across the Spectrum.

Authors:  Christoph Hoog Antink; Simon Lyra; Michael Paul; Xinchi Yu; Steffen Leonhardt
Journal:  Yearb Med Inform       Date:  2019-08-16

3.  Detection of Cardiopulmonary Activity and Related Abnormal Events Using Microsoft Kinect Sensor.

Authors:  Ali Al-Naji; Javaan Chahl
Journal:  Sensors (Basel)       Date:  2018-03-20       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.