Literature DB >> 27714601

Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.

J Ribamar Costa1, Daniel Chamié2, Alexandre A C Abizaid2, Expedito Ribeiro3, George C Meireles4, Maurício Prudente5, Carlos A Campos3, Juliana P Castro6, Ricardo Costa2, Pedro A Lemos3.   

Abstract

We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern.

Entities:  

Keywords:  Biodegradable polymer; Biolimus A9; Drug-eluting stents; Sirolimus

Mesh:

Substances:

Year:  2016        PMID: 27714601     DOI: 10.1007/s10554-016-0992-z

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  25 in total

Review 1.  American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.

Authors:  G S Mintz; S E Nissen; W D Anderson; S R Bailey; R Erbel; P J Fitzgerald; F J Pinto; K Rosenfield; R J Siegel; E M Tuzcu; P G Yock
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

Review 2.  Very late thrombosis after drug-eluting stents.

Authors:  Fausto Feres; J Ribamar Costa; Alexandre Abizaid
Journal:  Catheter Cardiovasc Interv       Date:  2006-07       Impact factor: 2.692

3.  Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

Authors:  Pedro A Lemos; Alexandre A C Abizaid; George C Meireles; Rogério Sarmento-Leite; Mauricio Prudente; Marcelo Cantarelli; Adriano D Dourado; Jose Mariani; Marco A Perin; Costantino Costantini; Ricardo A Costa; José Ribamar Costa; Daniel Chamie; Carlos A Campos; Expedito Ribeiro
Journal:  Cardiovasc Ther       Date:  2015-12       Impact factor: 3.023

4.  STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised controlled trial.

Authors:  Tom Adriaenssens; Giovanni J Ughi; Christophe Dubois; Dries De Cock; Kevin Onsea; Johan Bennett; Stefanus Wiyono; Peter Sinnaeve; Mark Coosemans; Bert Ferdinande; Ann Belmans; Jan D'hooge; Walter Desmet
Journal:  EuroIntervention       Date:  2016-04-08       Impact factor: 6.534

5.  Late incomplete apposition after drug-eluting stent implantation: incidence and potential for adverse clinical outcomes.

Authors:  Dimytri A Siqueira; Alexandre A Abizaid; Jose de Ribamar Costa; Fausto Feres; Luiz A Mattos; Rodolfo Staico; Andrea A Abizaid; Luiz F Tanajura; Aurea Chaves; Marinella Centemero; Amanda G M R Sousa; J Eduardo M R Sousa
Journal:  Eur Heart J       Date:  2007-05-03       Impact factor: 29.983

6.  Paclitaxel-eluting coronary stents in patients with diabetes mellitus: pooled analysis from 5 randomized trials.

Authors:  Ajay J Kirtane; Stephen G Ellis; Keith D Dawkins; Antonio Colombo; Eberhard Grube; Jeffrey J Popma; Martin Fahy; Martin B Leon; Jeffrey W Moses; Roxana Mehran; Gregg W Stone
Journal:  J Am Coll Cardiol       Date:  2008-02-19       Impact factor: 24.094

7.  A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.

Authors:  Gregg W Stone; Stephen G Ellis; David A Cox; James Hermiller; Charles O'Shaughnessy; James Tift Mann; Mark Turco; Ronald Caputo; Patrick Bergin; Joel Greenberg; Jeffrey J Popma; Mary E Russell
Journal:  N Engl J Med       Date:  2004-01-15       Impact factor: 91.245

8.  Four-year clinical follow-up of the first-in-man randomized comparison of a novel sirolimus eluting stent with abluminal biodegradable polymer and ultra-thin strut cobalt-chromium alloy: the INSPIRON-I trial.

Authors:  Marcos Danillo Peixoto Oliveira; Expedito E Ribeiro; Carlos M Campos; Henrique B Ribeiro; Bruno L R Faillace; Augusto C Lopes; Rodrigo B Esper; George X Meirelles; Marco A Perin; Alexandre Abizaid; Pedro A Lemos
Journal:  Cardiovasc Diagn Ther       Date:  2015-08

9.  A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.

Authors:  Marie-Claude Morice; Patrick W Serruys; J Eduardo Sousa; Jean Fajadet; Ernesto Ban Hayashi; Marco Perin; Antonio Colombo; G Schuler; Paul Barragan; Giulio Guagliumi; Ferenc Molnàr; Robert Falotico
Journal:  N Engl J Med       Date:  2002-06-06       Impact factor: 91.245

Review 10.  Meta-analysis of randomized trials on drug-eluting stents vs. bare-metal stents in patients with acute myocardial infarction.

Authors:  Adnan Kastrati; Alban Dibra; Christian Spaulding; Gerrit J Laarman; Maurizio Menichelli; Marco Valgimigli; Emilio Di Lorenzo; Christoph Kaiser; Ilkka Tierala; Julinda Mehilli; Melchior Seyfarth; Olivier Varenne; Maurits T Dirksen; Gianfranco Percoco; Attilio Varricchio; Undine Pittl; Mikko Syvänne; Maarten J Suttorp; Roberto Violini; Albert Schömig
Journal:  Eur Heart J       Date:  2007-09-27       Impact factor: 29.983

View more
  2 in total

1.  Cardiovascular imaging 2017 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Amer Alaiti; Hiram G Bezerra; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2018-06       Impact factor: 2.357

2.  One-Year Clinical Outcome of Inspiron Stent in All-Comers Population (Analysis from 790 Consecutive Patients).

Authors:  Felipe Falcão; Fabiano Cantarelli; Rodrigo Cantarelli; Flávio Mota; Manuela Navarro; Henrique Mota; Martinelly Santos; Daniel Cruz; André Sansônio; Marcelo Parente; Flávio Oliveira
Journal:  J Interv Cardiol       Date:  2020-12-17       Impact factor: 2.279

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.