Literature DB >> 27714451

Kinematic femoral alignment with gap balancing and patient-specific instrumentation in total knee arthroplasty: a randomized clinical trial.

Hagen Hommel1, Matthew P Abdel2, Carsten Perka3.   

Abstract

While patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) allows for transfer of the preoperative plan onto bony landmarks, the soft tissue balancing is not affected. The goals of this randomized clinical trial were to compare PSI and the measured resection technique (conventional) with PSI and the gap balancing technique. Fifty patients were randomized to TKA with conventional PSI (PSI-S) (n = 25) or to PSI with additional gap balancing (PSI-GB) (n = 25). All patients were clinically examined at 3 and 12 months postoperatively. Data on the range of motion, the Knee Society Score, the Western Ontario and McMasters Universities Osteoarthritis Index, the High-Flexion Knee Score (HFKS), and the Forgotten Joint Score (FJS) were compiled at follow-up. Statistically significant improvements were found for all clinical parameters in the PSI-GB group compared to the PSI-S group at 3 months postoperatively and for FS, FJS, and HFKS at 12 months. However, the relevance of these differences, as well as their effect on long-term outcomes, needs to be evaluated further. In conclusion, patient-specific instrumentation combined with gap balancing yielded good early clinical outcomes.

Entities:  

Keywords:  Extension-first technique; Gap balancing; Patient-specific instrumentation; Randomized clinical trial; Total knee arthroplasty

Mesh:

Year:  2016        PMID: 27714451     DOI: 10.1007/s00590-016-1865-9

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  25 in total

1.  No difference between tibia-first and femur-first techniques in TKA using computer-assisted surgery.

Authors:  Roland Becker; Markus Malzdorf; Christian Stärke; Pirtkien Randolf; Christoph Lohmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-02-25       Impact factor: 4.342

2.  Kinematically versus mechanically aligned total knee arthroplasty.

Authors:  H Gene Dossett; George J Swartz; Nicolette A Estrada; George W LeFevre; Bertram G Kwasman
Journal:  Orthopedics       Date:  2012-02-17       Impact factor: 1.390

3.  Preliminary results of a new surgical technique in total knee arthroplasty (TKA) using the native ligament tension for femoral implant positioning in varus osteoarthritis.

Authors:  Hagen Hommel; Carsten Perka; Tilman Pfitzner
Journal:  Arch Orthop Trauma Surg       Date:  2016-06-06       Impact factor: 3.067

4.  The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system.

Authors:  F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

5.  [Extension first technique for TKA implantation].

Authors:  R Hube; H O Mayr; T Kalteis; G Matziolis
Journal:  Oper Orthop Traumatol       Date:  2011-07       Impact factor: 1.154

6.  Femur positioning in navigated total knee arthroplasty.

Authors:  Tilman Pfitzner; Eric Röhner; Bernd Preininger; Carsten Perka; Georg Matziolis
Journal:  Orthopedics       Date:  2012-10       Impact factor: 1.390

7.  Measured resection versus gap balancing for total knee arthroplasty.

Authors:  Bryan D Springer; Sébastien Parratte; Matthew P Abdel
Journal:  Clin Orthop Relat Res       Date:  2014-02-27       Impact factor: 4.176

8.  A comparison of conventional and patient-specific instruments in total knee arthroplasty.

Authors:  Kiriakos Daniilidis; Carsten O Tibesku
Journal:  Int Orthop       Date:  2013-07-31       Impact factor: 3.075

9.  Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Jan Victor; Jan Dujardin; Hilde Vandenneucker; Nele Arnout; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

Review 10.  A systematic review and meta-analysis of patient-specific instrumentation for improving alignment of the components in total knee replacement.

Authors:  E Thienpont; P E Schwab; P Fennema
Journal:  Bone Joint J       Date:  2014-08       Impact factor: 5.082

View more
  5 in total

1.  Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review.

Authors:  Paweł Skowronek; Markus Arnold; Christian Starke; Agnieszka Bartyzel; Lukas B Moser; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-30       Impact factor: 4.342

2.  Gap balancing versus measured resection for primary total knee arthroplasty: a meta-analysis study.

Authors:  Filippo Migliorini; Jörg Eschweiler; Yasser El Mansy; Valentin Quack; Hanno Schenker; Markus Tingart; Arne Driessen
Journal:  Arch Orthop Trauma Surg       Date:  2020-05-14       Impact factor: 3.067

3.  Contralateral preoperative templating of lower limbs' mechanical angles is a reasonable option.

Authors:  Christophe Jacquet; Pierre Laumonerie; Sally LiArno; Ahmad Faizan; Akash Sharma; Louis Dagneaux; Matthieu Ollivier
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-05-09       Impact factor: 4.342

4.  Small Improvements in Postoperative Outcome with Gap Balancing Technique Compared with Measured Resection in Total Knee Arthroplasty.

Authors:  Hagen Hommel; Daniel Kunze; Peggy Hommel; Peter Fennema
Journal:  Open Orthop J       Date:  2017-11-10

5.  Weight Bearing Activities change the Pivot Position after Total Knee Arthroplasty.

Authors:  Philippe Moewis; Hagen Hommel; Adam Trepczynski; Leonie Krahl; Philipp von Roth; Georg N Duda
Journal:  Sci Rep       Date:  2019-06-24       Impact factor: 4.379