Literature DB >> 3458248

Contact pressures in the human hip joint measured in vivo.

W A Hodge, R S Fijan, K L Carlson, R G Burgess, W H Harris, R W Mann.   

Abstract

The pressures on human articular cartilage have been measured in vivo. An instrumented femoral head prosthesis that telemeters interarticular pressure at 10 discrete locations 253 times per second was implanted in apposition to natural acetabular cartilage. Data were acquired during surgery, recovery, rehabilitation, and normal activity, for longer than 1 year after surgery. Pressure magnitudes were synchronized with body-segment kinematic data and foot-floor force measurements so as to locate transduced pressure areas on the natural acetabulum and correlate movement kinematics and dynamics with local cartilage pressures. The data reveal very high local (up to 18 MPa) and nonuniform pressures, with abrupt spatial and temporal gradients, that correlate well both in magnitude and distribution with in vitro data and computer simulations of synovial joint mechanics. Peak pressures in vivo are, however, considerably higher than pressures measured in vitro under the putative forces experienced by the joint in life, particularly in normal movements where cocontraction occurs in agonist and antagonist muscles across the hip joint. Thus, extant gait-analysis studies which apply inverse Newtonian calculations to infer joint forces establish the lower limit on such forces, since such analyses include only the net muscular torques about the joint and cannot account for the contribution of the increment in joint force due to muscular cocontraction. Our data also contribute to the understanding of normal synovial joint tribology and the possible role of mechanical factors in the deterioration evident in osteoarthritis. Further, design criteria for both partial and total hip replacement prostheses and specific aspects of rehabilitation protocols following hip surgery (e.g., the extent to which crutches and canes unload the hip joint) warrant reconsideration in light of the extraordinary high pressures measured during the activities of daily living.

Entities:  

Mesh:

Year:  1986        PMID: 3458248      PMCID: PMC323410          DOI: 10.1073/pnas.83.9.2879

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  17 in total

1.  Contact pressures in the loaded human cadaver hip.

Authors:  W H Day; S A Swanson; M A Freeman
Journal:  J Bone Joint Surg Br       Date:  1975-08

2.  Hip mechanics.

Authors:  R A DENHAM
Journal:  J Bone Joint Surg Br       Date:  1959-08

3.  Influence of cartilage geometry on the pressure distribution in the human hip joint.

Authors:  P D Rushfeld; R W Mann; W H Harris
Journal:  Science       Date:  1979-04-27       Impact factor: 47.728

4.  A radio telemetry device for monitoring cartilage surface pressures in the human hip.

Authors:  C E Carlson; R W Mann; W H Harris
Journal:  IEEE Trans Biomed Eng       Date:  1974-07       Impact factor: 4.538

5.  The transmission of load through the human hip joint.

Authors:  A S Greenwald; J J O'Connor
Journal:  J Biomech       Date:  1971-12       Impact factor: 2.712

6.  In vivo records of hip loads using a femoral implant with telemetric output (a preliminary report).

Authors:  T A English; M Kilvington
Journal:  J Biomed Eng       Date:  1979-04

7.  A model for surface flow in cartilage.

Authors:  D E Kenyon
Journal:  J Biomech       Date:  1980       Impact factor: 2.712

8.  Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum--I. Ultrasonic measurement of acetabular surfaces, sphericity and cartilage thickness.

Authors:  P D Rushfeldt; R W Mann; W H Harris
Journal:  J Biomech       Date:  1981       Impact factor: 2.712

9.  An evaluation of the approaches of optimization models in the prediction of muscle forces during human gait.

Authors:  A G Patriarco; R W Mann; S R Simon; J M Mansour
Journal:  J Biomech       Date:  1981       Impact factor: 2.712

10.  Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum. II Instrumented endoprosthesis measurement of articular surface pressure distribution.

Authors:  P D Rushfeldt; R W Mann; W H Harris
Journal:  J Biomech       Date:  1981       Impact factor: 2.712

View more
  86 in total

Review 1.  Hydrogels for the repair of articular cartilage defects.

Authors:  Kara L Spiller; Suzanne A Maher; Anthony M Lowman
Journal:  Tissue Eng Part B Rev       Date:  2011-06-30       Impact factor: 6.389

2.  Functional characterisation of glucose transport in bovine articular chondrocytes.

Authors:  Robin A J Windhaber; Robert J Wilkins; David Meredith
Journal:  Pflugers Arch       Date:  2003-05-15       Impact factor: 3.657

Review 3.  Engineering lubrication in articular cartilage.

Authors:  Sean M McNary; Kyriacos A Athanasiou; A Hari Reddi
Journal:  Tissue Eng Part B Rev       Date:  2012-01-06       Impact factor: 6.389

Review 4.  Multiscale mechanics of articular cartilage: potentials and challenges of coupling musculoskeletal, joint, and microscale computational models.

Authors:  J P Halloran; S Sibole; C C van Donkelaar; M C van Turnhout; C W J Oomens; J A Weiss; F Guilak; A Erdemir
Journal:  Ann Biomed Eng       Date:  2012-05-31       Impact factor: 3.934

5.  Kruppel-like factor 4 upregulates matrix metalloproteinase 13 expression in chondrocytes via mRNA stabilization.

Authors:  Yuto Takeuchi; Sayuri Tatsuta; Akiyoshi Kito; Junji Fujikawa; Shousaku Itoh; Yuki Itoh; Shigehisa Akiyama; Takashi Yamashiro; Satoshi Wakisaka; Makoto Abe
Journal:  Cell Tissue Res       Date:  2020-06-15       Impact factor: 5.249

6.  Knee stabilization in patients with medial compartment knee osteoarthritis.

Authors:  Michael D Lewek; Dan K Ramsey; Lynn Snyder-Mackler; Katherine S Rudolph
Journal:  Arthritis Rheum       Date:  2005-09

7.  Finite element contact analysis of the hip joint.

Authors:  Fuziansyah Bachtar; Xian Chen; Toshiaki Hisada
Journal:  Med Biol Eng Comput       Date:  2006-07-06       Impact factor: 2.602

8.  Static compression of single chondrocytes catabolically modifies single-cell gene expression.

Authors:  Nic D Leipzig; Kyriacos A Athanasiou
Journal:  Biophys J       Date:  2007-12-07       Impact factor: 4.033

9.  Altered Golgi apparatus in hydrostatically loaded articular cartilage chondrocytes.

Authors:  J J Parkkinen; M J Lammi; A Pelttari; H J Helminen; M Tammi; I Virtanen
Journal:  Ann Rheum Dis       Date:  1993-03       Impact factor: 19.103

10.  Hydrostatic pressure induces expression of interleukin 6 and tumour necrosis factor alpha mRNAs in a chondrocyte-like cell line.

Authors:  K Takahashi; T Kubo; Y Arai; I Kitajima; M Takigawa; J Imanishi; Y Hirasawa
Journal:  Ann Rheum Dis       Date:  1998-04       Impact factor: 19.103

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.