Literature DB >> 27689836

Blue-Light Transmittance of Esthetic Monolithic CAD/CAM Materials With Respect to Their Composition, Thickness, and Curing Conditions.

B Stawarczyk, D Awad, N Ilie.   

Abstract

Determining the amount of blue light (360-540nm) passing through nine monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) materials depends on material thickness, initial irradiance, and the distance between the curing unit and the specimen's surface. A total of 180 specimens of two thicknesses (1 mm and 2 mm, n=10/subgroup) were fabricated from TelioCAD, VITA CAD-Temp (VCT), experimental nanocomposite, LAVA Ultimate (LU), VITA ENAMIC (VE), VITA MarkII (VM), IPS EmpressCAD (IEC), IPS e.maxCAD (IEM), and CELTRA DUO (CD). The irradiance passing through the CAD/CAM materials and thicknesses was measured using a light-emitting-diode curing unit with standard-power, high-power, and plasma modes by means of a USB4000 spectrometer. The curing unit was placed directly on the specimen's surface at 2- and 4-mm distances from the specimen's surface. Data were analyzed using a multivariate analysis and one-way analysis of variance with the post hoc Scheffé test (p<0.05). The highest transmitted irradiance was measured for VM and LU, followed by VCT and IEC, while the lowest values showed VE, followed by IEM and CD. The highest transmitted irradiance was recorded by exposing the material to the plasma mode, followed by the high- and standard-power modes. The measured irradiance was decreased by increasing the specimen's thickness from 1 to 2 mm. Fewer differences were measured when the curing unit was placed at 0 or 2 mm from the specimen's surface, and the irradiance passing through the specimens was lower at a distance of 4 mm.

Entities:  

Year:  2016        PMID: 27689836     DOI: 10.2341/15-252-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  4 in total

1.  Microleakage of composite crowns luted on CAD/CAM-milled human molars: a new method for standardized in vitro tests.

Authors:  Maximiliane Amelie Schlenz; Alexander Schmidt; Peter Rehmann; Thomas Niem; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2018-04-24       Impact factor: 3.573

2.  Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns.

Authors:  Ulrich Lohbauer; Renan Belli; Marco S Cune; Ulf Schepke
Journal:  SAGE Open Med Case Rep       Date:  2017-11-22

3.  Orthodontic bonding to silicate ceramics: impact of different pretreatment methods on shear bond strength between ceramic restorations and ceramic brackets.

Authors:  Rebecca Jungbauer; Christian Kirschneck; Christian M Hammer; Peter Proff; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2021-11-18       Impact factor: 3.573

4.  Light transmittance of CAD/CAM ceramics with different shades and thicknesses and microhardness of the underlying light-cured resin cement.

Authors:  Zahra Jafari; Homayoon Alaghehmand; Yasaman Samani; Mina Mahdian; Soraya Khafri
Journal:  Restor Dent Endod       Date:  2018-06-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.