| Literature DB >> 30135846 |
Zahra Jafari1, Homayoon Alaghehmand2, Yasaman Samani3, Mina Mahdian4, Soraya Khafri5.
Abstract
OBJECTIVES: The aim of this in vitro study was to evaluate the effects of the thickness and shade of 3 types of computer-aided design/computer-aided manufacturing (CAD/CAM) materials.Entities:
Keywords: Ceramics; Curing lights, dental; Hardness; Resin cements
Year: 2018 PMID: 30135846 PMCID: PMC6103544 DOI: 10.5395/rde.2018.43.e27
Source DB: PubMed Journal: Restor Dent Endod ISSN: 2234-7658
List of the materials used in this study
| Material | Brand name | Manufacturer | Composition |
|---|---|---|---|
| Feldspathic ceramic | VITABLOCS Mark II | VITA Zahnfabrik, Bad Säckingen, Germany | SiO2, Al2O3, Na2O, K2O, CaO, TiO2 |
| Lithium disilicate ceramic | IPS e.max CAD | IvoclarVivadent, Schaan, Liechtenstein | SiO2, Li2O, K2O, P2O5, ZrO2, ZnO, Al2O3, MgO |
| Zirconia-reinforced lithium disilicate ceramic | VITA Suprinity | VITA Zahnfabrik, Bad Säckingen, Germany | SiO2, Li2O, ZrO2, K2O, P2O5, Al2O3, CeO2 |
| Light-cured resin cement | Choice 2 | Bisco, Schaumburg, IL, USA | Strontium glass, amorphous silica, Bis-GMA |
Bis-GMA, bisphenol A-glycidyl methacrylate.
Light transmittance values (mW/cm2) for various types, thicknesses, and shades of computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics
| CAD/CAM material | A1 | A3 | ||
|---|---|---|---|---|
| 1 mm | 2 mm | 1 mm | 2 mm | |
| VITA Mark II | 320.0 ± 8.2a*† | 205.8 ± 5.8a* | 261.3 ± 19.5a† | 128.4 ± 7.9a |
| IPS e.max CAD | 253.0 ± 8.2b*† | 108.1 ± 4.3b* | 212.4 ± 8.1b† | 83.3 ± 5.0b |
| VITA Suprinity | 216.1 ± 5.8c*† | 98.4 ± 6.0c* | 163.5 ± 9.3c† | 63.7 ± 7.8c |
| Control | 800.0 | |||
Data are presented as mean ± standard deviation (n = 10). Different superscript lowercase letters indicate that there were statistically significant differences within each column.
*Indicates that there was a statistically significant difference in each thickness between 2 shades (p < 0.05); †indicates that there was a statistically significant difference in each shade between 2 thicknesses (p < 0.05).
Vickers microhardness numbers of choice 2 resin cement under various types, thicknesses, and shades of computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics
| CAD/CAM material | A1 | A3 | ||
|---|---|---|---|---|
| 1 mm | 2 mm | 1 mm | 2 mm | |
| VITA Mark II | 44.1 ± 1.3a*† | 31.2 ± 0.6a* | 36.3 ± 1.5a† | 25.9 ± 0.2a |
| IPS e.max CAD | 36.3 ± 0.9b*† | 22.1 ± 1.5b* | 31.2 ± 0.7b† | 20.4 ± 0.5b |
| VITA Suprinity | 32.7 ± 1.0c*† | 18.5 ± 1.0c* | 28.0 ± 0.7c† | 16.7 ± 0.5c |
| Control | 78.6 | |||
Data are presented as mean ± standard deviation (n = 10). Different superscript lowercase letters indicate that there were statistically significant differences within each column.
*Indicates that there was a statistically significant difference in each thickness between 2 shades (p < 0.05); †indicates that there was a statistically significant difference in each shade between 2 thicknesses (p < 0.05).