Literature DB >> 27681033

A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms.

Mojtaba Jafari Tadi1, Eero Lehtonen, Tero Hurnanen, Juho Koskinen, Jonas Eriksson, Mikko Pänkäälä, Mika Teräs, Tero Koivisto.   

Abstract

Heart rate monitoring helps in assessing the functionality and condition of the cardiovascular system. We present a new real-time applicable approach for estimating beat-to-beat time intervals and heart rate in seismocardiograms acquired from a tri-axial microelectromechanical accelerometer. Seismocardiography (SCG) is a non-invasive method for heart monitoring which measures the mechanical activity of the heart. Measuring true beat-to-beat time intervals from SCG could be used for monitoring of the heart rhythm, for heart rate variability analysis and for many other clinical applications. In this paper we present the Hilbert adaptive beat identification technique for the detection of heartbeat timings and inter-beat time intervals in SCG from healthy volunteers in three different positions, i.e. supine, left and right recumbent. Our method is electrocardiogram (ECG) independent, as it does not require any ECG fiducial points to estimate the beat-to-beat intervals. The performance of the algorithm was tested against standard ECG measurements. The average true positive rate, positive prediction value and detection error rate for the different positions were, respectively, supine (95.8%, 96.0% and ≃0.6%), left (99.3%, 98.8% and ≃0.001%) and right (99.53%, 99.3% and ≃0.01%). High correlation and agreement was observed between SCG and ECG inter-beat intervals (r  >  0.99) for all positions, which highlights the capability of the algorithm for SCG heart monitoring from different positions. Additionally, we demonstrate the applicability of the proposed method in smartphone based SCG. In conclusion, the proposed algorithm can be used for real-time continuous unobtrusive cardiac monitoring, smartphone cardiography, and in wearable devices aimed at health and well-being applications.

Mesh:

Year:  2016        PMID: 27681033     DOI: 10.1088/0967-3334/37/11/1885

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  20 in total

1.  Hypersampling of pseudo-periodic signals by analytic phase projection.

Authors:  Henning U Voss
Journal:  Comput Biol Med       Date:  2018-05-16       Impact factor: 4.589

2.  Efficient detection of aortic stenosis using morphological characteristics of cardiomechanical signals and heart rate variability parameters.

Authors:  Arash Shokouhmand; Nicole D Aranoff; Elissa Driggin; Philip Green; Negar Tavassolian
Journal:  Sci Rep       Date:  2021-12-10       Impact factor: 4.379

3.  Time-Frequency Distribution of Seismocardiographic Signals: A Comparative Study.

Authors:  Amirtaha Taebi; Hansen A Mansy
Journal:  Bioengineering (Basel)       Date:  2017-04-07

4.  Fast detection and data compensation for electrodes disconnection in long-term monitoring of dynamic brain electrical impedance tomography.

Authors:  Ge Zhang; Meng Dai; Lin Yang; Weichen Li; Haoting Li; Canhua Xu; Xuetao Shi; Xiuzhen Dong; Feng Fu
Journal:  Biomed Eng Online       Date:  2017-01-07       Impact factor: 2.819

5.  Gyrocardiography: A New Non-invasive Monitoring Method for the Assessment of Cardiac Mechanics and the Estimation of Hemodynamic Variables.

Authors:  Mojtaba Jafari Tadi; Eero Lehtonen; Antti Saraste; Jarno Tuominen; Juho Koskinen; Mika Teräs; Juhani Airaksinen; Mikko Pänkäälä; Tero Koivisto
Journal:  Sci Rep       Date:  2017-07-28       Impact factor: 4.379

Review 6.  Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review.

Authors:  Luwei Nie; Daniel Berckmans; Chaoyuan Wang; Baoming Li
Journal:  Sensors (Basel)       Date:  2020-04-17       Impact factor: 3.576

7.  High-Resolution Seismocardiogram Acquisition and Analysis System.

Authors:  Fábio Leitão; Eurico Moreira; Filipe Alves; Mário Lourenço; Olga Azevedo; João Gaspar; Luis A Rocha
Journal:  Sensors (Basel)       Date:  2018-10-13       Impact factor: 3.576

8.  Non-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients.

Authors:  Beren Semiz; Andrew M Carek; Jessica C Johnson; Shireen Ahmad; J Alex Heller; Florencia G Vicente; Stacey Caron; Charles W Hogue; Mozziyar Etemadi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2021-05-11       Impact factor: 5.772

9.  On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

Authors:  Prasan Kumar Sahoo; Hiren Kumar Thakkar; Wen-Yen Lin; Po-Cheng Chang; Ming-Yih Lee
Journal:  Sensors (Basel)       Date:  2018-01-28       Impact factor: 3.576

10.  Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers.

Authors:  Loc Luu; Anh Dinh
Journal:  Sensors (Basel)       Date:  2018-04-02       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.