Literature DB >> 33090962

Non-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients.

Beren Semiz, Andrew M Carek, Jessica C Johnson, Shireen Ahmad, J Alex Heller, Florencia G Vicente, Stacey Caron, Charles W Hogue, Mozziyar Etemadi, Omer T Inan.   

Abstract

OBJECTIVE: Optimizing peri-operative fluid management has been shown to improve patient outcomes and the use of stroke volume (SV) measurement has become an accepted tool to guide fluid therapy. The Transesophageal Doppler (TED) is a validated, minimally invasive device that allows clinical assessment of SV. Unfortunately, the use of the TED is restricted to the intra-operative setting in anesthetized patients and requires constant supervision and periodic adjustment for accurate signal quality. However, post-operative fluid management is also vital for improved outcomes. Currently, there is no device regularly used in clinics that can track patient's SV continuously and non-invasively both during and after surgery.
METHODS: In this paper, we propose the use of a wearable patch mounted on the mid-sternum, which captures the seismocardiogram (SCG) and electrocardiogram (ECG) signals continuously to predict SV in patients undergoing major surgery. In a study of 12 patients, hemodynamic data was recorded simultaneously using the TED and wearable patch. Signal processing and regression techniques were used to derive SV from the signals (SCG and ECG) captured by the wearable patch and compare it to values obtained by the TED.
RESULTS: The results showed that the combination of SCG and ECG contains substantial information regarding SV, resulting in a correlation and median absolute error between the predicted and reference SV values of 0.81 and 7.56 mL, respectively. SIGNIFICANCE: This work shows promise for the proposed wearable-based methodology to be used as an alternative to TED for continuous patient monitoring and guiding peri-operative fluid management.

Entities:  

Mesh:

Year:  2021        PMID: 33090962      PMCID: PMC8189504          DOI: 10.1109/JBHI.2020.3032938

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  38 in total

1.  Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery.

Authors:  H G Wakeling; M R McFall; C S Jenkins; W G A Woods; W F A Miles; G R Barclay; S C Fleming
Journal:  Br J Anaesth       Date:  2005-09-09       Impact factor: 9.166

2.  Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection.

Authors:  S E Noblett; C P Snowden; B K Shenton; A F Horgan
Journal:  Br J Surg       Date:  2006-09       Impact factor: 6.939

3.  Interaction between respiratory and RR interval oscillations at low frequencies.

Authors:  A Aguirre; G R Wodicka; C Maayan; D C Shannon
Journal:  J Auton Nerv Syst       Date:  1990-03

4.  Statistics corner: A guide to appropriate use of correlation coefficient in medical research.

Authors:  M M Mukaka
Journal:  Malawi Med J       Date:  2012-09       Impact factor: 0.875

5.  Less invasive hemodynamic monitoring in critically ill patients.

Authors:  Jean-Louis Teboul; Bernd Saugel; Maurizio Cecconi; Daniel De Backer; Christoph K Hofer; Xavier Monnet; Azriel Perel; Michael R Pinsky; Daniel A Reuter; Andrew Rhodes; Pierre Squara; Jean-Louis Vincent; Thomas W Scheeren
Journal:  Intensive Care Med       Date:  2016-05-07       Impact factor: 17.440

6.  A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms.

Authors:  Mojtaba Jafari Tadi; Eero Lehtonen; Tero Hurnanen; Juho Koskinen; Jonas Eriksson; Mikko Pänkäälä; Mika Teräs; Tero Koivisto
Journal:  Physiol Meas       Date:  2016-09-28       Impact factor: 2.833

7.  Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions.

Authors:  G Cybulski; E Michalak; E Koźluk; A Piatkowska; W Niewiadomski
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

8.  Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation.

Authors:  Md Mobashir Hasan Shandhi; Beren Semiz; Sinan Hersek; Nazli Goller; Farrokh Ayazi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2019-01-28       Impact factor: 5.772

9.  Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform.

Authors:  M M Hirschl; M Binder; M Gwechenberger; H Herkner; A Bur; H Kittler; A N Laggner
Journal:  Crit Care Med       Date:  1997-11       Impact factor: 7.598

Review 10.  Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery.

Authors:  S M Abbas; A G Hill
Journal:  Anaesthesia       Date:  2008-01       Impact factor: 6.955

View more
  2 in total

1.  Novel Noninvasive Biosensors and Artificial Intelligence for Optimized Heart Failure Management.

Authors:  Luke Neill; Mozziyar Etemadi; Liviu Klein; Omer T Inan
Journal:  JACC Basic Transl Sci       Date:  2022-04-04

2.  Enabling Continuous Wearable Reflectance Pulse Oximetry at the Sternum.

Authors:  Michael Chan; Venu G Ganti; J Alex Heller; Calvin A Abdallah; Mozziyar Etemadi; Omer T Inan
Journal:  Biosensors (Basel)       Date:  2021-12-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.