Leonardo Torquetti1, Carlos Arce2, Jesús Merayo-Lloves3, Guilherme Ferrara4, Paulo Ferrara4, Brenno Signorelli5, Armando Signorelli5. 1. Center for Excellence in Ophthalmology, Pará de Minas 35660-051, Brazil; Arce Clinic, Campinas 13106-028, Brazil. 2. Arce Clinic, Campinas 13106-028, Brazil. 3. Fernandez-Vega Eye Institute, Oviedo 33012, Spain. 4. Paulo Ferrara Eye Clinic, Belo Horizonte 30110-921, Brazil. 5. Campineiro Microsurgery Eye Center, Campinas 13013-161, Brazil.
Abstract
AIM: To evaluate corneal parameters measured with a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments (ICRS). METHODS: Fifty eyes of 40 keratoconus patients had Ferrara ICRS implantation from November 2010 to April 2014. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction, keratometry, asphericity, elevation, pachymetry, root mean square (RMS), spherical aberration and coma were studied. All patients were evaluated using a dual Scheimpflug system. RESULTS: The mean follow-up time after the procedure was 12.7mo. The mean UCVA improved from 0.82 to 0.31 (P<0.001); the mean BCVA improved from 0.42 to 0.05 (P<0.0001), the mean spherical refraction changed from -3.06±3.80 D to -0.80±2.5 D (P<0.0001) and the mean refraction astigmatism reduced from -4.51±2.08 D to -2.26±1.18 D (P<0.0001). The changes from preoperative to postoperative, in parameters of the anterior and posterior surface of the cornea, were statistically significant except the elevation posterior at the apex of the cornea and posterior asphericity. CONCLUSION: The implantation of Ferrara ICRS induces changes in both anterior and posterior surfaces of the cornea.
AIM: To evaluate corneal parameters measured with a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments (ICRS). METHODS: Fifty eyes of 40 keratoconus patients had Ferrara ICRS implantation from November 2010 to April 2014. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction, keratometry, asphericity, elevation, pachymetry, root mean square (RMS), spherical aberration and coma were studied. All patients were evaluated using a dual Scheimpflug system. RESULTS: The mean follow-up time after the procedure was 12.7mo. The mean UCVA improved from 0.82 to 0.31 (P<0.001); the mean BCVA improved from 0.42 to 0.05 (P<0.0001), the mean spherical refraction changed from -3.06±3.80 D to -0.80±2.5 D (P<0.0001) and the mean refraction astigmatism reduced from -4.51±2.08 D to -2.26±1.18 D (P<0.0001). The changes from preoperative to postoperative, in parameters of the anterior and posterior surface of the cornea, were statistically significant except the elevation posterior at the apex of the cornea and posterior asphericity. CONCLUSION: The implantation of Ferrara ICRS induces changes in both anterior and posterior surfaces of the cornea.
Entities:
Keywords:
dual Scheimpflug; intrastromal corneal ring segments; keratoconus
Authors: Mohammad Nasser Hashemian; Mohammad Ali Zare; Mehrdad Mohammadpour; Firouzeh Rahimi; Mohammad Reza Fallah; Fereydoun Keramat Panah Journal: J Ophthalmic Vis Res Date: 2014 Jul-Sep