Literature DB >> 27664429

Conversion Coefficients for Proton Beams using Standing and Sitting Male Hybrid Computational Phantom Calculated in Idealized Irradiation Geometries.

M C Alves1, W S Santos2, C Lee3, W E Bolch4, J G Hunt5, A B Carvalho Júnior1.   

Abstract

The aim of this study was the calculation of conversion coefficients for absorbed doses per fluence (DT/Φ) using the sitting and standing male hybrid phantom (UFH/NCI) exposure to monoenergetic protons with energy ranging from 2 MeV to 10 GeV. Sex-averaged effective dose per fluence (E/Φ) using the results of DT/Φ for the male and female hybrid phantom in standing and sitting postures were also calculated. Results of E/Φ of UFH/NCI standing phantom were also compared with tabulated effective dose conversion coefficients provided in ICRP publication 116. To develop an exposure scenario implementing the male UFH/NCI phantom in sitting and standing postures was used the radiation transport code MCNPX. Whole-body irradiations were performed using the recommended irradiation geometries by ICRP publication 116 antero-posterior (AP), postero-anterior (PA), right and left lateral, rotational (ROT) and isotropic (ISO). In most organs, the conversion coefficients DT/Φ were similar for both postures. However, relative differences were significant for organs located in the lower abdominal region, such as prostate, testes and urinary bladder, especially in the AP geometry. Results of effective dose conversion coefficients were 18% higher in the standing posture of the UFH/NCI phantom, especially below 100 MeV in AP and PA. In lateral geometry, the conversion coefficients values below 20 MeV were 16% higher in the sitting posture. In ROT geometry, the differences were below 10%, for almost all energies. In ISO geometry, the differences in E/Φ were negligible. The results of E/Φ of UFH/NCI phantom were in general below the results of the conversion coefficients provided in ICRP publication 116.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27664429      PMCID: PMC6257014          DOI: 10.1093/rpd/ncw271

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  15 in total

1.  Calculation of the radiation environment caused by galactic cosmic rays for determining air crew exposure.

Authors:  A Ferrari; M Pelliccioni; T Rancati
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

2.  On the conversion coefficients for cosmic ray dosimetry.

Authors:  A Ferrari; M Pelliccioni
Journal:  Radiat Prot Dosimetry       Date:  2003       Impact factor: 0.972

3.  ICRP Publication 116. Conversion coefficients for radiological protection quantities for external radiation exposures.

Authors:  N Petoussi-Henss; W E Bolch; K F Eckerman; A Endo; N Hertel; J Hunt; M Pelliccioni; H Schlattl; M Zankl
Journal:  Ann ICRP       Date:  2010 Apr-Oct

4.  Application of a sitting MIRD phantom for effective dose calculations.

Authors:  Richard H Olsher; Kenneth A Van Riper
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

5.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

6.  Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms.

Authors:  Tatsuhiko Sato; Akira Endo; Maria Zankl; Nina Petoussi-Henss; Koji Niita
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

7.  Calculated organ equivalent doses for individuals in a sitting posture above a contaminated ground and a PET imaging room.

Authors:  Lin Su; Bin Han; X George Xu
Journal:  Radiat Prot Dosimetry       Date:  2011-04-22       Impact factor: 0.972

8.  Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident.

Authors:  Eun Young Han; Wi-Ho Ha; Young-Woo Jin; Wesley E Bolch; Choonsik Lee
Journal:  J Radiol Prot       Date:  2014-12-11       Impact factor: 1.394

9.  The UF family of reference hybrid phantoms for computational radiation dosimetry.

Authors:  Choonsik Lee; Daniel Lodwick; Jorge Hurtado; Deanna Pafundi; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

10.  Fluence-to-dose conversion coefficients for monoenergetic proton beams based on the VIP-Man anatomical model.

Authors:  A Bozkurt; X G Xu
Journal:  Radiat Prot Dosimetry       Date:  2004-08-10       Impact factor: 0.972

View more
  3 in total

1.  Comparison of photon organ and effective dose coefficients for PIMAL stylized phantom in bent positions in standard irradiation geometries.

Authors:  Shaheen Dewji; K Lisa Reed; Mauritius Hiller
Journal:  Radiat Environ Biophys       Date:  2017-06-22       Impact factor: 1.925

2.  Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries.

Authors:  K Bales; S Dewji; E Sanchez
Journal:  Radiat Environ Biophys       Date:  2018-08-23       Impact factor: 1.925

3.  Development of a novel program for conversion from tetrahedral-mesh-based phantoms to DICOM dataset for radiation treatment planning: TET2DICOM.

Authors:  Bo-Wi Cheon; Se Hyung Lee; Min Cheol Han; Chul Hee Min; Haegin Han; Chan Hyeong Kim; Jin Sung Kim
Journal:  J Appl Clin Med Phys       Date:  2021-10-11       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.