Literature DB >> 27659309

Percutaneous internal fixation of pelvic fractures.

A J Stevenson1, B Swartman2, A T Bucknill3.   

Abstract

BACKGROUND: Percutaneous internal fixation of pelvic fractures is increasing in popularity with multiple new techniques reported.
OBJECTIVES: The purpose of this article is to outline the imaging, indication, planning, equipment, surgical technique and complications of these methods.
METHODS: A review of the literature is provided and the techniques for anterior and posterior pelvic stabilisation are discussed.
RESULTS: High-quality preoperative CT scans are essential in planning for this technique. The anterior internal fixator ("InFix") is an effective method for stabilising the anterior ring and should be usually used in conjunction with posterior fixation. Good technique avoids neurovascular injury, which can be a devastating complication. The retrograde anterior column screw (RACS) is a technique that can be used in most patients, although in smaller patients smaller screw diameters may be needed. The entry point for the screw is more lateral in women than men. Iliosacral screws (ISS) are an effective method of posterior stabilisation and can be placed using 2D or 3D fluoroscopy, computer navigation or CT navigation.
CONCLUSION: Percutaneous fixation of pelvic fractures requires high-quality imaging and can be aided by computer navigation. Safe techniques are reproducible; however, not all patients and fracture patterns can be treated using these techniques.

Entities:  

Keywords:  Complications; Fracture fixation, internal; Fractures, bone; Minimally invasive surgical procedures; Pelvis

Mesh:

Year:  2017        PMID: 27659309     DOI: 10.1007/s00113-016-0225-x

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  64 in total

1.  The lateral sacral triangle--a decision support for secure transverse sacroiliac screw insertion.

Authors:  T Mendel; H Noser; D Wohlrab; K Stock; F Radetzki
Journal:  Injury       Date:  2011-10       Impact factor: 2.586

2.  Accuracy of computer-assisted iliosacral screw placement using a hybrid operating room.

Authors:  P H Richter; F Gebhard; C Dehner; A Scola
Journal:  Injury       Date:  2015-12-12       Impact factor: 2.586

3.  CT-guided iliosacral screw placement.

Authors:  Richard H Daffner; Robert L Sciulli
Journal:  Semin Musculoskelet Radiol       Date:  2013-10-07       Impact factor: 1.777

4.  Sex-specific differences of the infraacetabular corridor: a biomorphometric CT-based analysis on a database of 523 pelves.

Authors:  Florian Gras; Heiko Gottschling; Manuel Schröder; Ivan Marintschev; Nils Reimers; Rainer Burgkart
Journal:  Clin Orthop Relat Res       Date:  2014-09-27       Impact factor: 4.176

5.  Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series.

Authors:  Rahul Vaidya; Robert Colen; Jonathan Vigdorchik; Fredrick Tonnos; Anil Sethi
Journal:  J Orthop Trauma       Date:  2012-01       Impact factor: 2.512

Review 6.  Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis.

Authors:  Jörn Zwingmann; Oliver Hauschild; Gerrit Bode; Norbert P Südkamp; Hagen Schmal
Journal:  Arch Orthop Trauma Surg       Date:  2013-06-08       Impact factor: 3.067

7.  The effect of sacral fracture malreduction on the safe placement of iliosacral screws.

Authors:  Mark C Reilly; Christopher M Bono; Behrang Litkouhi; Michael Sirkin; Fred F Behrens
Journal:  J Orthop Trauma       Date:  2003-02       Impact factor: 2.512

Review 8.  Maneuvering the retrograde medullary screw in pubic ramus fractures.

Authors:  Rami Mosheiff; Meir Liebergall
Journal:  J Orthop Trauma       Date:  2002-09       Impact factor: 2.512

9.  Percutaneous iliosacral screw fixation in unstable pelvic ring lesions: the interest of O-ARM CT-guided navigation.

Authors:  C Coste; Y Asloum; P S Marcheix; P Dijoux; J L Charissoux; C Mabit
Journal:  Orthop Traumatol Surg Res       Date:  2013-04-29       Impact factor: 2.256

10.  Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus.

Authors:  Li-hai Zhang; Li-cheng Zhang; Qing-hua Si; Yuan Gao; Xiu-yun Su; Zhe Zhao; Pei-fu Tang
Journal:  BMC Musculoskelet Disord       Date:  2016-01-15       Impact factor: 2.362

View more
  2 in total

Review 1.  Computer navigation-assisted minimally invasive percutaneous screw placement for pelvic fractures.

Authors:  Tong Yu; Xue-Liang Cheng; Yang Qu; Rong-Peng Dong; Ming-Yang Kang; Jian-Wu Zhao
Journal:  World J Clin Cases       Date:  2020-06-26       Impact factor: 1.337

2.  The first use of laparoscopy to treat pelvic ring fractures: A case report.

Authors:  Rémi Di Francia; Jean-Loup Tanner; Julien Marolleau
Journal:  Int J Surg Case Rep       Date:  2020-09-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.