Literature DB >> 12571496

The effect of sacral fracture malreduction on the safe placement of iliosacral screws.

Mark C Reilly1, Christopher M Bono, Behrang Litkouhi, Michael Sirkin, Fred F Behrens.   

Abstract

OBJECTIVES: To determine the effects of cranial displacement on the safe placement of iliosacral screws for zone II sacral fractures.
DESIGN: Computer imaging and dimensional analysis of a human cadaveric sacral fracture model.
SETTING: Cadaveric dissection, Orthopaedic Research Laboratories, Newark, New Jersey. MAIN OUTCOME MEASUREMENTS: Six cadaveric pelves with simulated zone II sacral fractures were imaged with computed tomography at controlled cranial displacements of 5, 10, 15, and 20 mm. The area of contact at the fracture site and volume of bone available for iliosacral screw placement was graphically measured using both two- and three-dimensional computer modeling. Areas of contact were also represented in terms of the maximal number of 7.0-mm screws that could be simultaneously implanted.
RESULTS: Cross-sectional contact area was decreased by 30%, 56%, 81%, and 90% at 5, 10, 15 and 20 mm of displacement, respectively. Volume of bone was decreased by 21%, 25%, 26%, and 34% for 5, 10, 15 and 20 mm of displacement, respectively. In 50% of the specimens at 15 mm and 66% of the specimens with 20 mm displacement, two iliosacral screws could not be contained simultaneously within bone. In 17% of the specimens displaced 15 mm and 50% of the specimens displaced 20 mm, the cross-sectional area was insufficient to contain a single iliosacral screw.
CONCLUSIONS: Although previous authors have accepted up to 15 mm of cranial displacement, the data demonstrate substantial compromise of available screw space with displacements greater than 1 cm. Fracture reduction is mandatory, as screw placement with residual displacement of 10 mm or more can endanger adjacent neural and vascular structures.

Entities:  

Mesh:

Year:  2003        PMID: 12571496     DOI: 10.1097/00005131-200302000-00002

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  19 in total

1.  Factors influencing the accuracy of iliosacral screw placement in trauma patients.

Authors:  Lars Grossterlinden; Johannes Rueger; Philip Catala-Lehnen; Martin Rupprecht; Wolfgang Lehmann; Andreas Rücker; Daniel Briem
Journal:  Int Orthop       Date:  2010-07-20       Impact factor: 3.075

2.  [Computer-assisted arthrodesis of the sacroiliac joint].

Authors:  F Gebhard; M Sarkar; G Maier; L Kinzl; M Arand
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

3.  Can lumbopelvic fixation salvage unstable complex sacral fractures?

Authors:  Clifford B Jones; Debra L Sietsema; Martin F Hoffmann
Journal:  Clin Orthop Relat Res       Date:  2012-08       Impact factor: 4.176

4.  [Bony sacroiliac corridor. A virtual volume model for the accurate insertion of transarticular screws].

Authors:  T Mendel; K Appelt; P Kuhn; N Suhm
Journal:  Unfallchirurg       Date:  2008-01       Impact factor: 1.000

5.  Gun barrel view of the anterior pelvic ring for percutaneous anterior column or superior pubic ramus screw placement.

Authors:  Nicholas Quercetti; Brandon Horne; Zac DiPaolo; Michael J Prayson
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-10-07

6.  Sex-specific differences of the infraacetabular corridor: a biomorphometric CT-based analysis on a database of 523 pelves.

Authors:  Florian Gras; Heiko Gottschling; Manuel Schröder; Ivan Marintschev; Nils Reimers; Rainer Burgkart
Journal:  Clin Orthop Relat Res       Date:  2014-09-27       Impact factor: 4.176

7.  Transsacral Osseous Corridor Anatomy Is More Amenable To Screw Insertion In Males: A Biomorphometric Analysis of 280 Pelves.

Authors:  Florian Gras; Heiko Gottschling; Manuel Schröder; Ivan Marintschev; Gunther O Hofmann; Rainer Burgkart
Journal:  Clin Orthop Relat Res       Date:  2016-07-08       Impact factor: 4.176

8.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

9.  [Percutaneous internal fixation of pelvic fractures. German version].

Authors:  A J Stevenson; B Swartman; A T Bucknill
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

Review 10.  Percutaneous internal fixation of pelvic fractures.

Authors:  A J Stevenson; B Swartman; A T Bucknill
Journal:  Unfallchirurg       Date:  2017-12       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.