Literature DB >> 27649474

The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy.

Anton Mans1, Danny Schuring, Mark P Arends, Cornelia A J M Vugts, Jochem W H Wolthaus, Heidi T Lotz, Marjan Admiraal, Rob J W Louwe, Michel C Öllers, Jeroen B van de Kamer.   

Abstract

In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, inevitably, a Dutch focus. This paper is a condensed version of these guidelines, the full report in English is freely available from the NCS website www.radiationdosimetry.org. After describing the transition from IMRT to VMAT, the paper addresses machine quality assurance (QA) and treatment planning system (TPS) commissioning for VMAT. The final section discusses patient specific QA issues such as the use of class solutions, measurement devices and dose evaluation methods.

Entities:  

Mesh:

Year:  2016        PMID: 27649474     DOI: 10.1088/0031-9155/61/19/7221

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Dosimetric accuracy of dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) for primary brain tumours.

Authors:  Gregory Smyth; Philip M Evans; Jeffrey C Bamber; Henry C Mandeville; A Rollo Moore; Liam C Welsh; Frank H Saran; James L Bedford
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

Review 2.  Complexity metrics for IMRT and VMAT plans: a review of current literature and applications.

Authors:  Sophie Chiavassa; Igor Bessieres; Magali Edouard; Michel Mathot; Alexandra Moignier
Journal:  Br J Radiol       Date:  2019-07-24       Impact factor: 3.039

3.  A novel and independent method for time-resolved gantry angle quality assurance for VMAT.

Authors:  Todsaporn Fuangrod; Peter B Greer; Benjamin J Zwan; Michael P Barnes; Joerg Lehmann
Journal:  J Appl Clin Med Phys       Date:  2017-07-13       Impact factor: 2.102

4.  Auditing local methods for quality assurance in radiotherapy using the same set of predefined treatment plans.

Authors:  Enrica Seravalli; Antonetta C Houweling; Leo Van Battum; Thom A Raaben; Marc Kuik; Jacco A de Pooter; Marion P R Van Gellekom; Jochem Kaas; Wilfred de Vries; Erik A Loeff; Jeroen B Van de Kamer
Journal:  Phys Imaging Radiat Oncol       Date:  2018-02-02

5.  In vivo dosimetry with an electronic portal imaging device for prostate cancer radiotherapy with an endorectal balloon.

Authors:  Bo Sterckx; Isabell Steinseifer; Markus Wendling
Journal:  Phys Imaging Radiat Oncol       Date:  2019-11-09

6.  Survey of patient-specific quality assurance practice for IMRT and VMAT.

Authors:  Gordon H Chan; Lee C L Chin; Ady Abdellatif; Jean-Pierre Bissonnette; Lesley Buckley; Daria Comsa; Dal Granville; Jenna King; Patrick L Rapley; Aaron Vandermeer
Journal:  J Appl Clin Med Phys       Date:  2021-06-19       Impact factor: 2.102

7.  Evaluation of 4-Hz log files and secondary Monte Carlo dose calculation as patient-specific quality assurance for VMAT prostate plans.

Authors:  Philipp Szeverinski; Matthias Kowatsch; Thomas Künzler; Marco Meinschad; Patrick Clemens; Alexander F DeVries
Journal:  J Appl Clin Med Phys       Date:  2021-06-20       Impact factor: 2.102

  7 in total