OBJECTIVE: The objective of this study was to compare the accuracy of four different digital intraoral scanners and the effects of buccal brackets and orthodontic wire.
METHODS: For this study, three sets of models (Control model, BKT model with buccal bracket, and WBKT model with buccal bracket and orthodontic wire) were scanned using four different types of intraoral scanners: E4D dentist, iTero, Trios, and Zfx IntraScan. The mesiodistal width of the teeth, intercanine width, and intermolar width measured by four scanners were compared. Three-dimensional (3D) images of the brackets were taken using the four scanners. Data were analyzed with one-way ANOVA, independent t test, and post-hoc Tukey test at a significance level of P < 0.05.
RESULTS: When comparing the 3D images with manual measurements using a traditional caliper, iTero and Trios showed the highest accuracy in horizontal measurements.iTero had the lowest values in Devmax-min of maxillary intermolar and intercanine widths (0.16 mm and 0.20 mm, respectively), whereas Trios had the lowest values in Devmax-min of mandibular intermolar and intercanine widths (0.36 mm and 0.14 mm, respectively). The horizontal variables were barely affected by the presence of buccal brackets and orthodontic wire. Comparison of 3D bracket images scanned by the four scanners showed differences in image distortion among the scanners. Bracket characteristics did not affect the 3D bracket images.
CONCLUSIONS: The four intraoral scanners used in this study differed in accuracy. However, the results acquired by iTero and Trios were more reliable. Effects of buccal brackets and orthodontic wire on the 3D images taken by intraoral scanners were not clinically significant.

Entities:  

Mesh:

Year:  2016        PMID: 27644178

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  7 in total

1.  Effect of the presence of orthodontic brackets on intraoral scans.

Authors:  Sung-Ja Kang; Youn-Ju Kee; Kyungmin Clara Lee
Journal:  Angle Orthod       Date:  2021-01-01       Impact factor: 2.079

2.  The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study.

Authors:  Maximiliane Amelie Schlenz; Katharina Klaus; Alexander Schmidt; Bernd Wöstmann; Marco Mersmann; Sabine Ruf; Niko Christian Bock
Journal:  Clin Oral Investig       Date:  2022-09-15       Impact factor: 3.606

3.  Comparison of the occlusal contact area of virtual models and actual models: a comparative in vitro study on Class I and Class II malocclusion models.

Authors:  Hyemin Lee; Jooly Cha; Youn-Sic Chun; Minji Kim
Journal:  BMC Oral Health       Date:  2018-06-19       Impact factor: 2.757

4.  Accuracy of a Method to Monitor Root Position Using a 3D Digital Crown/Root Model during Orthodontic Treatments.

Authors:  Kaho Ogawa; Yoshiki Ishida; Yukinori Kuwajima; Cliff Lee; Jacob R Emge; Mitsuru Izumisawa; Kazuro Satoh; Shigemi Ishikawa-Nagai; John D Da Silva; Chia-Yu Chen
Journal:  Tomography       Date:  2022-02-23

Review 5.  Intraoral Scanners in Orthodontics: A Critical Review.

Authors:  Isidora Christopoulou; Eleftherios G Kaklamanos; Miltiadis A Makrygiannakis; Ilias Bitsanis; Paula Perlea; Apostolos I Tsolakis
Journal:  Int J Environ Res Public Health       Date:  2022-01-27       Impact factor: 3.390

6.  The Effects of Orthodontic Brackets on the Time and Accuracy of Digital Impression Taking.

Authors:  Hyojin Heo; Minji Kim
Journal:  Int J Environ Res Public Health       Date:  2021-05-16       Impact factor: 3.390

7.  Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva.

Authors:  Jihu Song; Minji Kim
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.