Literature DB >> 27639808

Wear, strength, modulus and hardness of CAD/CAM restorative materials.

Nathaniel C Lawson1, Ritika Bansal2, John O Burgess3.   

Abstract

OBJECTIVE: To measure the mechanical properties of several CAD/CAM materials, including lithium disilicate (e.max CAD), lithium silicate/zirconia (Celtra Duo), 3 resin composites (Cerasmart, Lava Ultimate, Paradigm MZ100), and a polymer infiltrated ceramic (Enamic).
METHODS: CAD/CAM blocks were sectioned into 2.5mm×2.5mm×16mm bars for flexural strength and elastic modulus testing and 4mm thick blocks for hardness and wear testing. E.max CAD and half the Celtra Duo specimens were treated in a furnace. Flexural strength specimens (n=10) were tested in a three-point bending fixture. Vickers microhardness (n=2, 5 readings per specimen) was measured with a 1kg load and 15s dwell time. The CAD/CAM materials as well as labial surfaces of human incisors were mounted in the UAB wear device. Cusps of human premolars were mounted as antagonists. Specimens were tested for 400,000 cycles at 20N force, 2mm sliding distance, 1Hz frequency, 24°C, and 33% glycerin lubrication. Volumetric wear and opposing enamel wear were measured with non-contact profilometry. Data were analyzed with 1-way ANOVA and Tukey post-hoc analysis (alpha=0.05). Specimens were observed with SEM.
RESULTS: Properties were different for each material (p<0.01). E.max CAD and Celtra Duo were generally stronger, stiffer, and harder than the other materials. E.max CAD, Celtra Duo, Enamic, and enamel demonstrated signs of abrasive wear, whereas Cerasmart, Lava Ultimate, Paradigm MZ100 demonstrated signs of fatigue. SIGNIFICANCE: Resin composite and resin infiltrated ceramic materials have demonstrated adequate wear resistance for load bearing restorations, however, they will require at least similar material thickness as lithium disilicate restorations due to their strength.
Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CAD/CAM; Elastic modulus; Enamel; Flexural strength; Hardness; Wear

Mesh:

Substances:

Year:  2016        PMID: 27639808     DOI: 10.1016/j.dental.2016.08.222

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  38 in total

1.  [Effect of occlusal thickness design on the fracture resistance of endocrowns restored with lithium disilicate ceramic and zirconia].

Authors:  Zhen-Xiang Lin; Zai-Xing Pan; Qi-Qing Ye; Zhi-Qiang Zheng; Jie Lin
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-12-01

2.  Polishing effects and wear performance of chairside CAD/CAM materials.

Authors:  Mike Matzinger; Sebastian Hahnel; Verena Preis; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-05-16       Impact factor: 3.573

3.  Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia.

Authors:  M Wendler; M R Kaizer; R Belli; U Lohbauer; Y Zhang
Journal:  Dent Mater       Date:  2020-01-30       Impact factor: 5.304

4.  An in situ and ex situ study of the microstructural evolution of a novel lithium silicate glass-ceramic during crystallization firing.

Authors:  Angel L Ortiz; Camila S Rodrigues; Fernando Guiberteau; Yu Zhang
Journal:  Dent Mater       Date:  2020-04-08       Impact factor: 5.304

5.  In Vitro Evaluation of the Effect of Different Surface Treatments of a Hybrid Ceramic on the Microtensile Bond Strength to a Luting Resin Cement.

Authors:  Fariba Motevasselian; Zahra Amiri; Nasim Chiniforush; Mansoreh Mirzaei; Van Thompson
Journal:  J Lasers Med Sci       Date:  2019-10-01

6.  Wear behavior and abrasiveness of monolithic CAD/CAM ceramics after simulated mastication.

Authors:  Ahmed Mahmoud Fouda; Osama Atta; Amr Shebl Kassem; Mohamed Desoky; Christoph Bourauel
Journal:  Clin Oral Investig       Date:  2022-07-11       Impact factor: 3.606

7.  Clinical survival of chair-side generated monolithic lithium disilicate crowns:10-year results.

Authors:  Angelika Rauch; Sven Reich; Luise Dalchau; Oliver Schierz
Journal:  Clin Oral Investig       Date:  2017-11-04       Impact factor: 3.573

8.  Retention of CAD/CAM resin composite crowns following different bonding protocols.

Authors:  Amir H Nejat; Jinwhan Lee; Shreya Shah; Chee Paul Lin; Prajakta Kulkarni; Ramakiran Chavali; Nathaniel C Lawson
Journal:  Am J Dent       Date:  2018-04       Impact factor: 1.522

9.  Bond Strength of Metal and Ceramic Brackets on Resin Nanoceramic Material With Different Surface Treatments.

Authors:  Mehmet Kara; Özgür Demir; Mehmet Doğru
Journal:  Turk J Orthod       Date:  2020-06-01

10.  In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years.

Authors:  Gintare Burian; Kurt Erdelt; Josef Schweiger; Christine Keul; Daniel Edelhoff; Jan-Frederik Güth
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.