Markus Troeltzsch1, Matthias Troeltzsch2, Philipp Kauffmann3, Rudolph Gruber3, Phillipp Brockmeyer3, Norman Moser3, Anna Rau4, Henning Schliephake3. 1. Department of Maxillofacial Surgery (Head: Prof. Dr. Dr. H. Schliephake), University of Goettingen, Germany. Electronic address: troeltzsch@gmx.net. 2. Department of Maxillofacial Surgery, Ludwig - Maximilians - University of Munich, Germany. 3. Department of Maxillofacial Surgery (Head: Prof. Dr. Dr. H. Schliephake), University of Goettingen, Germany. 4. Department of Anesthesiology, University of Goettingen, Germany.
Abstract
PURPOSE: To evaluate the efficacy of grafting materials in lateral and vertical ridge augmentations. MATERIALS AND METHODS: A systematic review of the literature on the clinical use of grafting materials of the years 1995 to April 2015 was conducted using electronic search of PubMed and Cochrane libraries and hand search of eight print journals. A total of 184 papers were included, comprising 6182 patients. Parameters evaluated were observation period [months], bone formation [histologic area%], defect fill [%], horizontal and vertical gain [mm], loss of augmented volume [mm], complication rate [%], and implant survival rate [%]. Results are expressed as weighted means ± SD. RESULTS: Results were obtained after a weighted mean observation period of 27.4 months (range 3-168 months). Bone formation in the augmented areas varied from 33.2 ± 14.9% for allogeneic grafts to 56.0 ± 25.6% for mixtures of autogenous and other grafting materials. Defect fill in dehiscence defects ranged from 51.0 ± 13.6% (synthetic) to 85.8 ± 13.4% (xenogeneic) for the different materials, with an overall weighted mean of 79.8 ± 18.7%. Weighted mean horizontal gain for all particulate grafting materials was 3.7 ± 1.2 mm, with variation between 2.2 ± 1.2 mm (synthetic) and 4.5 ± 1.0 mm (mixtures of autogenous bone with allogeneic/xenogeneic grafting material) without statistical significance. Weighted overall mean vertical gain was 3.7 ± 1.4 mm. Vertical gain was substantially higher when space-making barrier materials such as titanium meshes were used; however this was also associated with strong increase in complication rate. Block grafts achieved higher horizontal gain by approximately 1 mm. The use of block grafts achieved significantly increased vertical gain compared to particulate material only when autogenous block grafts from extraoral donor sites were used. CONCLUSION: Horizontal and vertical gain by 3.7 mm on average can be achieved using particulate materials. This can be increased by using titanium meshes. Substantial vertical gains beyond this dimension require the use of extraoral bone block grafts.
PURPOSE: To evaluate the efficacy of grafting materials in lateral and vertical ridge augmentations. MATERIALS AND METHODS: A systematic review of the literature on the clinical use of grafting materials of the years 1995 to April 2015 was conducted using electronic search of PubMed and Cochrane libraries and hand search of eight print journals. A total of 184 papers were included, comprising 6182 patients. Parameters evaluated were observation period [months], bone formation [histologic area%], defect fill [%], horizontal and vertical gain [mm], loss of augmented volume [mm], complication rate [%], and implant survival rate [%]. Results are expressed as weighted means ± SD. RESULTS: Results were obtained after a weighted mean observation period of 27.4 months (range 3-168 months). Bone formation in the augmented areas varied from 33.2 ± 14.9% for allogeneic grafts to 56.0 ± 25.6% for mixtures of autogenous and other grafting materials. Defect fill in dehiscence defects ranged from 51.0 ± 13.6% (synthetic) to 85.8 ± 13.4% (xenogeneic) for the different materials, with an overall weighted mean of 79.8 ± 18.7%. Weighted mean horizontal gain for all particulate grafting materials was 3.7 ± 1.2 mm, with variation between 2.2 ± 1.2 mm (synthetic) and 4.5 ± 1.0 mm (mixtures of autogenous bone with allogeneic/xenogeneic grafting material) without statistical significance. Weighted overall mean vertical gain was 3.7 ± 1.4 mm. Vertical gain was substantially higher when space-making barrier materials such as titanium meshes were used; however this was also associated with strong increase in complication rate. Block grafts achieved higher horizontal gain by approximately 1 mm. The use of block grafts achieved significantly increased vertical gain compared to particulate material only when autogenous block grafts from extraoral donor sites were used. CONCLUSION: Horizontal and vertical gain by 3.7 mm on average can be achieved using particulate materials. This can be increased by using titanium meshes. Substantial vertical gains beyond this dimension require the use of extraoral bone block grafts.
Authors: I Sanz-Martin; L Ferrantino; F Vignoletti; J Nuñez; N Baldini; M Duvina; J Alcaraz; M Sanz Journal: Clin Oral Investig Date: 2017-10-03 Impact factor: 3.573
Authors: Rene Rothweiler; Christian Gross; Emely Bortel; Sarah Früh; Javier Gerber; Elodie Boller; Jonas Wüster; Andres Stricker; Tobias Fretwurst; Gerhard Iglhaut; Susanne Nahles; Rainer Schmelzeisen; Bernhard Hesse; Katja Nelson Journal: Front Bioeng Biotechnol Date: 2022-06-17
Authors: Carlos Navarro Cuéllar; Manuel Tousidonis Rial; Raúl Antúnez-Conde; Santiago Ochandiano Caicoya; Ignacio Navarro Cuéllar; Gema Arenas de Frutos; Ángela Sada Urmeneta; María Isabel García-Hidalgo Alonso; Carlos Navarro Vila; José Ignacio Salmerón Escobar Journal: J Clin Med Date: 2021-04-29 Impact factor: 4.241
Authors: Lara Schorn; Christoph Sproll; Michelle Ommerborn; Christian Naujoks; Norbert R Kübler; Rita Depprich Journal: Head Face Med Date: 2017-06-07 Impact factor: 2.151
Authors: Önder Solakoglu; Werner Götz; Maren C Kiessling; Christopher Alt; Christoph Schmitz; Eckhard U Alt Journal: World J Stem Cells Date: 2019-02-26 Impact factor: 5.326