Literature DB >> 27605260

Acoustic structure quantification by using ultrasound Nakagami imaging for assessing liver fibrosis.

Po-Hsiang Tsui1,2,3, Ming-Chih Ho4, Dar-In Tai5, Ying-Hsiu Lin2, Chiao-Yin Wang6, Hsiang-Yang Ma6.   

Abstract

Acoustic structure quantification (ASQ) is a recently developed technique widely used for detecting liver fibrosis. Ultrasound Nakagami parametric imaging based on the Nakagami distribution has been widely used to model echo amplitude distribution for tissue characterization. We explored the feasibility of using ultrasound Nakagami imaging as a model-based ASQ technique for assessing liver fibrosis. Standard ultrasound examinations were performed on 19 healthy volunteers and 91 patients with chronic hepatitis B and C (n = 110). Liver biopsy and ultrasound Nakagami imaging analysis were conducted to compare the METAVIR score and Nakagami parameter. The diagnostic value of ultrasound Nakagami imaging was evaluated using receiver operating characteristic (ROC) curves. The Nakagami parameter obtained through ultrasound Nakagami imaging decreased with an increase in the METAVIR score (p < 0.0001), representing an increase in the extent of pre-Rayleigh statistics for echo amplitude distribution. The area under the ROC curve (AUROC) was 0.88 for the diagnosis of any degree of fibrosis (≥F1), whereas it was 0.84, 0.69, and 0.67 for ≥F2, ≥F3, and ≥F4, respectively. Ultrasound Nakagami imaging is a model-based ASQ technique that can be beneficial for the clinical diagnosis of early liver fibrosis.

Entities:  

Mesh:

Year:  2016        PMID: 27605260      PMCID: PMC5015103          DOI: 10.1038/srep33075

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


The major consequence of chronic liver diseases is the increased deposition of fibrotic tissues within the liver, resulting in the development of cirrhosis and hepatocellular carcinoma1. Percutaneous liver biopsy is currently the gold standard for assessing liver fibrosis. Because of the invasiveness of and sampling errors23 in liver biopsy, many researchers have been focusing on developing imaging techniques for the noninvasive evaluation of liver fibrosis. Among all possibilities, ultrasound provides real-time screening of the liver and has been widely used in routine clinical examinations. The most commonly used ultrasound methods for assessing liver fibrosis are ultrasound elastography techniques, such as transient elastography, acoustic radiation force impulse imaging, and shear wave elastography4. Although liver stiffness is strongly correlated with the fibrosis stage, elastography only assesses stiffness and not fibrosis5. In all histological fibrosis scoring systems, the stages are based on morphological analyses, wherein the formation of septa and nodules is the major factor6. Therefore, morphological analysis–based conventional grayscale ultrasound may contain valuable information beyond that provided by elastography for assessing liver fibrosis. The acoustic structure quantification (ASQ) technique has recently gained attention as a tool for characterizing liver parenchyma578910. ASQ is performed on a basic pulse-echo ultrasound grayscale system for characterizing tissues through the statistical analysis of the acquired ultrasound echo signals11. Because normal liver parenchyma consists of a three-dimensional arrangement of microstructures that are smaller than the wavelength of ultrasound used clinically (unresolvable scatterers), the statistics of the echo amplitude follow Rayleigh distribution11121314. During liver fibrosis, the fibrotic structures and nodules develop and become larger than the wavelength (resolvable scatterers), resulting in a relatively high degree of variance in the scattering cross-sections of scatterers. In this condition, the echo texture is overall coarse and heterogeneous, and the echo amplitude distribution deviates from the Rayleigh distribution. Using ASQ, the degree of deviation from the Rayleigh distribution can be quantified for assessing liver fibrosis. The ASQ software has been commercialized and is available in Toshiba ultrasound scanners (Apilo XG, Toshiba Medical Systems, Otawara, Japan). The echo amplitude statistics can be quantified more precisely by estimating the shape parameters in the statistical models. The Nakagami parameter (denoted by m) of the Nakagami distribution is a simple and general method for describing all conditions of the echo amplitude distribution15161718. Numerous studies have revealed that Nakagami parameter–based ultrasound parametric imaging can visualize changes in the echo amplitude distribution; therefore, it has already been used in various applications, such as breast tumor classification19, cataract detection20, vascular flow analysis21, thermal ablation monitoring22, heart muscle characterization23, and liver fibrosis evaluation in rats2425. Previously, we preliminarily validated the feasibility of ultrasound Nakagami imaging for detecting liver fibrosis in humans. It was shown that the fibrosis score based on the features of liver surface (smooth, irregular, or undulated), liver parenchyma (homogeneous, heterogeneous, or coarse), hepatic vessel (smooth, obscure, or narrow), and spleen size (< 20 cm2 or >20 cm2) correlates with the severity of liver fibrosis26, and we observed that the Nakagami parameter correlated with the sonographic fibrosis score assigned according to the above features of the ultrasound image14. To further investigate the diagnostic ability of Nakagami imaging for assessing liver fibrosis, histological findings should be used as the ground truth for performance evaluations. This study investigated the relationship between the Nakagami parameter and histological findings in patients with liver fibrosis.

Materials and Methods

Study Population

This prospective study was approved by the Institutional Review Boards of National Taiwan University Hospital and Chang Gung Memorial Hospital. All participants signed informed consent forms. All the experimental methods were carried out in accordance with the approved guidelines. Between August 2014 and July 2015, we enrolled 19 healthy volunteers from Chang Gung University as the control group and 91 patients (59 patients from Taiwan University Hospital and 32 patients from Chang Gung Memorial Hospital) as the study group. The volunteers had no drinking and smoking habits, no remarkable past medical history, and no clinical symptoms and signs of liver and renal parenchymal diseases. Patients with confirmed chronic hepatitis B or C infection scheduled for liver biopsy or partial liver resection were recruited.

Clinical and laboratory examination

Age, sex, weight, height, and body mass index (BMI) was recorded for each patient. Venous blood samples collected after overnight fasting for 8 h were used for measuring the aspartate aminotransferase (AST) level, platelet (PLT) count, and AST-to-PLT ratio (APRI).

Ultrasound Examination

A portable clinical ultrasound scanner (Model 3000, Terason, Burlington, MA, USA) and a convex transducer with a central frequency of 3 MHz, 128 elements, and a pulse length of approximately 2.3 mm (Model 5C2A, Terason) were used for sonographic imaging. All participants underwent a standard-care ultrasound examination. For each participant, five valid grayscale images of the liver parenchyma (no acoustic shadowing artifacts and exclusion of large vessels in the region of analysis) were obtained from the right intercostal view by a gastroenterologist. The focus and depth of imaging were set at 4 and 8 cm, respectively. The grayscale image data were stored as a ULT file dedicated to the Terason ultrasound system. Raw echo signal data consisting of 128 scan lines corresponding to each grayscale image were obtained by converting the ULT files into MAT files, which were read using the MATLAB software for offline data processing and ultrasound Nakagami imaging.

Ultrasound Nakagami imaging

Echo amplitude distribution measured from tissues can be classified as Rayleigh, pre-Rayleigh, and post-Rayleigh distributions27. The variation of the Nakagami parameter from 0 to 1 corresponds to a change in the echo amplitude distribution from the pre-Rayleigh to Rayleigh distribution; Nakagami parameters higher than 1 indicate that the statistics of the echo amplitude conform to the post-Rayleigh distribution15. Therefore, the Nakagami parameter allows the quantification of echo amplitude distributions with specific physical meanings. The detailed techniques of Nakagami parameter estimation and imaging were described previously142829. In brief, (i) The envelope image was obtained using the absolute value of the Hilbert Transform of each echo signal filtered using empirical mode decomposition28; (ii) A square window within the envelope image was used to collect local amplitude data for estimating the Nakagami parameter, which is assigned as the new pixel located in the center of the window. The side length of the window was three times the pulse length of the transducer1424252729. The maximum likelihood estimator (MLE) derived by Greenwood30 was selected to calculate the Nakagami parameter because MLE yields a lower variance in estimating the Nakagami parameter313233. (iii) The window was allowed to move throughout the envelope image in a one-pixel step, and step 2 was repeated to construct a Nakagami parameter map, which was further converted into a fan-shaped image according to the geometry of the curve probe. The key factor for a stable estimation of the Nakagami parameter is the axial length of the envelope signal, not the number of data points or the length of the lateral side of the window. As long as the sampling rate of the analog-to-digital converter in the imaging system satisfies the Nyquist theory, the signal waveform can be reconstructed without the aliasing effect to describe the trend of the variation in the envelope amplitude; and (iv) a primary region of interest (ROI) was manually set on the image of the liver parenchyma. The pixel values (i.e., the Nakagami parameter) within the ROI, which served as the biomarker of liver fibrosis, were averaged. The image data processing was performed using MATLAB software (Version R2012a, The MathWorks, Inc., MA, USA).

Histological analysis

After ultrasound examination, liver resection or percutaneous liver biopsy was performed within 1 wk. For each patient scheduled for liver resection, one specimen taken for histological examination was located far away from the main lesion (>1 cm). For each patient underwent liver biopsy, one specimen was obtained from the right liver lobe through an intercostal approach under ultrasound imaging guidance. All specimens were placed in formalin, and sent to the Department of Pathology for histological examinations. Samples were embedded in paraffin, stained with hematoxylineosin (H&E) and picrosirius red (PR), and read on-site by expert liver histologists. Samples showing a minimum of six portal tracts were considered adequate for histological evaluation5. Liver fibrosis was semiquantitatively evaluated using the METAVIR scoring system: F0, no fibrosis; F1, portal fibrosis with no septa; F2, portal fibrosis with few septa; F3, bridging fibrosis with many septa; and F4, cirrhosis (nodular stage)6.

Statistical analysis

The Nakagami parameter as a function of the METAVIR score was expressed as the median and interquartile range (IQR). The Pearson correlation coefficient r and the probability value (p) were calculated for evaluating the correlation between the Nakagami parameter and METAVIR score. Independent t-test was performed to compare the difference in the Nakagami parameter between each group (p < 0.05 was considered statistically significant). The receiver operating characteristic (ROC) curve analysis at 95% confidence interval (CI) was performed to obtain the area under the ROC (AUROC). The AUROC was used to determine the predictive value of the Nakagami parameter for diagnosing each fibrosis threshold: F0 versus F1–F4 (≥F1), F0–F1 versus F2–F4 (≥F2), F0–F2 versus F3–F4 (≥F3), and F0–F3 versus F4 (≥F4). In addition, sensitivity, specificity, and accuracy were reported. All statistical analyses were performed using SigmaPlot software (Version 12.0, Systat Software, Inc., CA, USA).

Results

The characteristics of healthy volunteers in the control group are summarized in Table 1, and the patients’ demographic data and biological and histological findings are summarized in Table 2. Because the volunteers had a normal BMI and no remarkable past medical history or clinical symptoms of liver parenchymal diseases, the control group data were categorized as F0 for comparison with the patient data. The PR-stained section images obtained from patients with different stages of liver fibrosis are shown in Fig. 1. Figures 2 and 3 present the grayscale B-mode and Nakagami images obtained from the healthy volunteers and patients with liver fibrosis, respectively. The brightness of the Nakagami image typically decreased as the METAVIR scores increased from F1 to F4. The Nakagami parameters corresponding to each liver fibrosis stage are presented in Fig. 4. The dynamic range (i.e., the difference between the maximum and minimum values) of the Nakagami parameter was 0.53–0.85. The Nakagami parameter monotonically decreased as the severity of liver fibrosis increased (r = −0.45, p < 0.0001). The median Nakagami parameter was 0.77 (IQR: 0.73–0.79) for F0, 0.72 (IQR: 0.68–0.75) for F1, 0.68 (IQR: 0.64–0.70) for F2, 0.68 (IQR: 0.66–0.71) for F3, and 0.69 (IQR: 0.65–0.70) for F4. A significant difference was observed between F0 and F1 (p = 0.0006) and F1 and F2 (p = 0.0033). However, no significant difference was observed between F2 and F3 (p = 0.45) and F3 and F4 (p = 0.91). The ROC curves for diagnosing different liver fibrosis stages are presented in Fig. 5. The AUROCs (95% CI) were 0.88 (0.79–0.95), 0.84 (0.75–0.92), 0.69 (0.58–0.79), and 0.67 (0.56–0.77) for fibrosis stages ≥F1, ≥F2, ≥F3, and ≥F4, respectively. The performance profile for ultrasound Nakagami imaging is presented in Table 3.
Table 1

The characteristics of healthy volunteers in the control group.

CharacteristicsValue
Male/Female16/3 (n = 19)
Age, years
 Mean ± standard deviation (range)22.1 ± 1.4 (20–26)
 Median22
BMI, kg/m2
 Mean ± standard deviation (range)23.0 ± 4.4 (17.9–32.9)
 Median20.7

Note—Unless otherwise noted, data are numbers of patients. BMI: body mass index. BMI was calculated and defined according the Department of Health in Taiwan: optimal BMI was defined as 18.5 ≦ BMI < 24 kg/m2, overweight as 24 ≦ BMI < 27 kg/m2, and obesity was defined as BMI ≧ 27 kg/m2.

Table 2

Patients’ demographic data and biological and histological findings obtained by liver biopsy examination.

CharacteristicsValue
Male/Female72/19
Age, years
 Mean ± standard deviation (range)55.4 ± 11.0 (26–75)
 Median58
BMI, kg/m2
 Mean ± standard deviation (range)25.1 ± 5.2 (18.3–65.7)
 Median24.2
AST level, ×ULN
 Mean ± standard deviation (range)1.4 ± 1.6 (0.4–8.6)
 Median0.8
PLT, 103/mm3
 Mean ± standard deviation (range)187.5 ± 67.9 (70–431)
 Median176
APRI
 Mean ± standard deviation (range)0.8 ± 0.5 (0.1–2.4)
 Median0.6
HCC43
HBV infection40
HCV infection8
Histological fibrosis stage
 F04
 F119
 F223
 F312
 F433

Note—Unless otherwise noted, data are numbers of patients. BMI: body mass index, AST: aspartate aminotransferase, PLT: platelet count, APRI: AST/PLT, HCC: hepatocellular carcinoma, HBV: hepatitis B virus, HCV: hepatitis C virus, ULN: upper limit of normal. Normal AST levels for female and male subjects are less than 35 U/L and less than 50 U/L, respectively.

Figure 1

PR-stained sections (100 magnification) obtained from patients’ livers with different degrees of fibrosis from F0 to F4.

(a) F0: no fibrosis; (b) F1: fibrous expansion of portal areas without septa (i.e., portal fibrosis); (c) F2: portal fibrosis with few septa was observed; (d) F3: fibrous expansion of portal areas with marked bridging or septa (i.e., septal fibrosis); (e) F4: the tissue is composed of nodules surrounded completely by fibrosis (i.e., cirrhosis).

Figure 2

Grayscale B-mode images obtained from the healthy volunteers and patients with liver fibrosis.

(a) F0; (b) F1; (c) F2; (d) F3; (e) F4. B-mode images were reconstructed using log-compressed envelopes of ultrasound signals provided by the Terason ultrasound scanner.

Figure 3

Ultrasound Nakagami images obtained from the healthy volunteers and patients with liver fibrosis.

(a) F0; (b) F1; (c) F2; (d) F3; (e) F4. The brightness of the Nakagami image typically decreased as the METAVIR scores increased from F0 to F4.

Figure 4

The Nakagami parameters corresponding to each liver fibrosis stage.

Data are expressed using box plots. The Nakagami parameter decreased with an increase in the histological fibrosis stage, representing an increase in the degree of pre-Rayleigh statistics for the echo amplitude distribution.

Figure 5

ROC curves for diagnosing different liver fibrosis stages.

The AUROC obtained using ultrasound Nakagami imaging in our study was 0.88, 0.84, 0.69, and 0.67 for ≥F1, ≥F2, ≥F3, and ≥F4, respectively.

Table 3

Clinical performance of ultrasound Nakagami imaging in the assessment of liver fibrosis in this study.

Parameter≧F1≧F2≧F3≧F4
Cutoff value0.71680.71640.70250.7025
Sensitivity, %75.86 (65.50 to 84.40)85.29 (74.61 to 92.72)71.11 (55.69 to 83.63)72.73 (54.48 to 86.70)
Specificity, %91.30 (71.96 to 98.93)76.19 (60.55 to 87.95)64.62 (51.77 to 76.08)59.74 (47.94 to 70.77)
LR+8.71953.58212.00991.8065
LR−0.26440.19310.44710.4565
PPV, %97.1085.2958.9244.64
NPV, %51.2176.1977.7785.18
AUROC0.88 (0.79–0.95)0.84 (0.75–0.92)0.69 (0.58–0.79)0.67 (0.56–0.77)

LR+: positive likelihood ratio, LR−: negative likelihood ratio, PPV: positive predictive value, NPV: negative predictive value, AUROC: area under the receiver operating characteristics curve.

Discussion

In this study, we proposed ultrasound Nakagami imaging as an alternative for the acoustic structure characterization of liver tissue. A decrease in the brightness of the Nakagami image of the liver represents the liver parenchyma deviating from the normal state (a relatively homogeneous medium) to the fibrotic state (a medium with a relatively high degree of variance in the scattering cross-sections of scatterers). The Nakagami parameter is inversely proportional to the severity of liver fibrosis. The advantage of ultrasound Nakagami imaging is that the echo amplitude distribution can be quantified with a specific physical meaning (i.e., m < 1: pre-Rayleigh distribution, m = 1: Rayleigh distribution, and m > 1: post-Rayleigh distribution). We observed that the Nakagami parameters of normal livers were smaller than 1; this finding is consistent with that of a previous study that reported that the real echo amplitude distribution is not a perfect Rayleigh statistic because of the presence of small vessel walls10. As the METAVIR score increased, the Nakagami parameter decreased, representing an increase in the degree of pre-Rayleigh statistics for the echo amplitude distribution. For clinicians, the most critical question regarding a patient with chronic liver disease is whether the patient has cirrhosis1. Ultrasound elastography, including elastography strain imaging, transient elastography, acoustic radiation force impulse imaging, and shear wave elastography, has been demonstrated to produce a reliable evaluation of liver cirrhosis43435. A recently published consensus statement indicated that ultrasound elastography may discriminate between the early (METAVIR scores F0 and F1) and late stages (METAVIR scores F3 and F4) of liver fibrosis1. However, hepatic inflammation influences the estimation of liver stiffness363738. By contrast, elastography strain imaging is operator dependent, and both transient elastography and shear wave elastography are performed only when a specific probe is available and system requirements are met. When these functional elastography systems are unavailable in a clinical setting, using a conventional grayscale scanner for yielding liver fibrosis-related information becomes crucial. Compared with ultrasound elastography, ultrasound Nakagami imaging can be a complementary tool for diagnosing liver fibrosis. Nakagami imaging may be less affected by the inflammatory activity because a study reported no significant correlation between the measurements of the echo amplitude distribution and blood alanine aminotransferase level5. Using approaches based on acoustic structure characterization may benefit liver fibrosis assessment in patients with chronic hepatitis B. Moreover, using a morphological ultrasound technique prevents interference from ascites, which is a contraindication for transient elastography5. In particular, the algorithms of ultrasound Nakagami imaging are completely compatible with those of a conventional ultrasound B-mode system, making the combination of the routine liver examinations and liver fibrosis assessment more feasible. The diagnostic value of the conventional ASQ in quantifying the degree of liver fibrosis remains questionable because of inconsistent findings. The performances of ASQ in liver fibrosis assessment reported in literature are summarized in Table 4. Toyoda et al.11 and Ricci et al.39 have shown that ASQ can differentiate between individual fibrosis stages. No significant correlation was observed between ASQ parameters and liver fibrosis stages in Kramer et al.7 and Keller et al.40. To date, the most satisfactory performance of ASQ was in Huang et al. (AUROC was 0.84, 0.86, and 0.83 for ≥F2, ≥F3, and ≥F4, respectively)5. By contrast, the AUROC obtained using ultrasound Nakagami imaging in our study was 0.88, 0.84, 0.69, and 0.67 for ≥F1, ≥F2, ≥F3, and ≥F4, respectively. Ultrasound Nakagami imaging not only improves the diagnostic performance but also efficiently discriminates between the normal and fibrotic stages of the liver tissue, implying that Nakagami imaging has great potential in the early detection of liver fibrosis (≥F1). This finding has not been revealed in previous ASQ literatures.
Table 4

Performances of ASQ in liver fibrosis assessment reported in previous literatures.

AuthorsYearPatients (n)DiseasesAUROC or correlation with fibrosis stages
≧F1≧F2≧F3≧F4Probability value
Toyoda et al.112009148HCV<0.05
Ricci et al.39201377HBV, HCV0.710.77<0.05
Kramer et al.7201480HBV, HCV0.460.38>0.05
Huang et al.52015114HBV0.840.860.83<0.001
Huang et al.92015113<0.001
Keller et al.40201551HBV, HCV>0.05

AUROC: area under the ROC curve, HCV: hepatitis C virus, HBV: hepatitis B virus.

This study has some limitations that should be addressed in future work. First, the patients were recruited from two hospitals. Therefore, ultrasound scanning and fibrosis scoring were performed by different gastroenterologists and pathologists, respectively. Scoring and scanning errors between data may occur. Second, few patients with histologically proven F0 were recruited. More patients with different types of liver diseases should also be enrolled. Moreover, Nakagami imaging is a model-based ASQ technique for quantifying echo amplitude distribution. Thus, the ASQ-related problems may be encountered when using Nakagami imaging for assessing liver fibrosis. For instance, the lack of a standardized analysis protocol may yield inconsistent results9. A coexisting hepatic steatosis may lead to interferences affecting fibrosis detection3940. Future studies focusing on establishing a standardized analysis procedure, exploring the effect of steatosis, and validating the reproducibility of ultrasound Nakagami imaging are warranted. Finally, according to current results and discussion, advantages and limitations of the Nakagami model-based ASQ and the frequently used imaging techniques for liver fibrosis assessment are compared in Table 5. The superiorities of Nakagami imaging over the other methods may include (i) the ability in early detection of liver fibrosis, (ii) using a conventional B-mode machine only as a system requirement, and (iii) potentially a less dependency of inflammation activity because the echo amplitude distribution has no significant correlation with blood alanine aminotransferase level5.
Table 5

A comparison of noninvasive imaging methods in liver fibrosis assessment.

 Advantages or potentialsLimitations
Nakagami model-based ASQSuperior for detecting early liver fibrosisMay be affected by fatty liver
A conventional B-mode system is needed only Worse performance in cirrhosisdetection
May be less affected by the effect of inflammation
Ultrasound elastographySuperior for detecting liver cirrhosisInfluence of inflammation
Good reproducibility
Computer tomography (CT)Superior for detecting liver cirrhosisRadiation dose
Hard for routine uses
Magnetic resonance (MR) elastographySuperior for detecting fibrosisExpensive
No inter-rater variabilityHard for routine uses

Note—Comparisons of Nakagami imaging and ultrasound elastography in the assessment of liver fibrosis are based on the clinical results and discussion in this work. The advantages and limitations of CT and MR elastography are referred to a review paper41.

Concluding remarks

Ultrasound Nakagami imaging is a model-based ASQ technique for assessing liver fibrosis. The Nakagami model-based ASQ visualizes changes in the echo amplitude distribution and may have an impact on clinical detection of early liver fibrosis by using standard B-mode ultrasound examinations. We suggest that Nakagami imaging is a complementary tool and may be further combined with elastography in the future. The Nakagami-based ASQ detects early liver fibrosis by imaging the signal amplitude distribution for evaluations of microstructures. Ultrasound elastography is responsible for identifying advanced fibrosis by measuring the liver stiffness. Two-dimensional analysis based on microstructure analysis and stiffness measurement may be a good strategy for future ultrasound diagnosis of liver fibrosis.

Additional Information

How to cite this article: Tsui, P.-H. et al. Acoustic structure quantification by using ultrasound Nakagami imaging for assessing liver fibrosis. Sci. Rep. 6, 33075; doi: 10.1038/srep33075 (2016).
  34 in total

1.  Effect of adaptive threshold filtering on ultrasonic nakagami parameter to detect variation in scatterer concentration.

Authors:  Po-Hsiang Tsui; Yung-Liang Wan; Chih-Chung Huang; Ming-Chen Wang
Journal:  Ultrason Imaging       Date:  2010-10       Impact factor: 1.578

2.  Statistics of boundaries in ultrasonic B-scan images.

Authors:  P Mohana Shankar
Journal:  Ultrasound Med Biol       Date:  2014-10-22       Impact factor: 2.998

3.  Flow quantification with nakagami parametric imaging for suppressing contrast microbubbles attenuation.

Authors:  Xiaolin Gu; Min Wei; Yujin Zong; Hujie Jiang; Mingxi Wan
Journal:  Ultrasound Med Biol       Date:  2013-02-04       Impact factor: 2.998

4.  A pilot approach for quantitative assessment of liver fibrosis using ultrasound: preliminary results in 79 cases.

Authors:  Hiroyuki Yamada; Masaaki Ebara; Tadashi Yamaguchi; Shinichirou Okabe; Hiroyuki Fukuda; Masaharu Yoshikawa; Takashi Kishimoto; Hisahiro Matsubara; Hiroyuki Hachiya; Hiroshi Ishikura; Hiromitsu Saisho
Journal:  J Hepatol       Date:  2005-09-15       Impact factor: 25.083

5.  Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement.

Authors:  Richard G Barr; Giovanna Ferraioli; Mark L Palmeri; Zachary D Goodman; Guadalupe Garcia-Tsao; Jonathan Rubin; Brian Garra; Robert P Myers; Stephanie R Wilson; Deborah Rubens; Deborah Levine
Journal:  Radiology       Date:  2015-06-16       Impact factor: 11.105

6.  Hepatic Steatosis: Assessment with Acoustic Structure Quantification of US Imaging.

Authors:  Jee-Young Son; Jae Young Lee; Nam-Joon Yi; Kwang-Woong Lee; Kyung-Suk Suh; Kwang Gi Kim; Jeong Min Lee; Joon Koo Han; Byung Ihn Choi
Journal:  Radiology       Date:  2015-06-29       Impact factor: 11.105

7.  Correlation between ultrasonographic and pathologic diagnoses of hepatitis B and C virus-related cirrhosis.

Authors:  Chao-Hung Hung; Sheng-Nan Lu; Jing-Houng Wang; Chuan-Mo Lee; Tsung-Ming Chen; Hung-Da Tung; Chien-Hung Chen; Wu-Shiung Huang; Chi-Sin Changchien
Journal:  J Gastroenterol       Date:  2003       Impact factor: 7.527

8.  Using ultrasound backscattering signals and Nakagami statistical distribution to assess regional cataract hardness.

Authors:  Miguel Caixinha; Danilo A Jesus; Elena Velte; Mário J Santos; Jaime B Santos
Journal:  IEEE Trans Biomed Eng       Date:  2014-07-08       Impact factor: 4.538

Review 9.  Real-time elastography in the assessment of liver fibrosis: a review of qualitative and semi-quantitative methods for elastogram analysis.

Authors:  Francesco Paparo; Francesco Corradi; Luca Cevasco; Matteo Revelli; Andrea Marziano; Lucio Molini; Giovanni Cenderello; Giovanni Cassola; Gian Andrea Rollandi
Journal:  Ultrasound Med Biol       Date:  2014-06-25       Impact factor: 2.998

10.  Comparison of Acoustic Structure Quantification (ASQ), shearwave elastography and histology in patients with diffuse hepatopathies.

Authors:  Jan Keller; Tanja Eva-Maria Kaltenbach; Mark Martin Haenle; Suemeyra Oeztuerk; Tilmann Graeter; Richard Andrew Mason; Thomas Seufferlein; Wolfgang Kratzer
Journal:  BMC Med Imaging       Date:  2015-12-03       Impact factor: 1.930

View more
  12 in total

1.  Ultrasound Image Computerized Analysis for Non-invasive Quantitative Evaluation of Hepatic Fibrosis.

Authors:  Georgiana Nagy; Maria Adriana Neag; Mihaela Gordan; Doinita Crisan; Mircea Petru; Romeo Chira
Journal:  Turk J Gastroenterol       Date:  2021-10       Impact factor: 1.852

2.  Ultrasound Sample Entropy Imaging: A New Approach for Evaluating Hepatic Steatosis and Fibrosis.

Authors:  Hsien-Jung Chan; Zhuhuang Zhou; Jui Fang; Dar-In Tai; Jeng-Hwei Tseng; Ming-Wei Lai; Bao-Yu Hsieh; Tadashi Yamaguchi; Po-Hsiang Tsui
Journal:  IEEE J Transl Eng Health Med       Date:  2021-11-02       Impact factor: 3.316

3.  Generalized formulations producing a Burr distribution of speckle statistics.

Authors:  Kevin J Parker; Sedigheh S Poul
Journal:  J Med Imaging (Bellingham)       Date:  2022-04-01

4.  Diagnosis of liver fibrosis in patients with hepatitis B-related liver disease using ultrasound with wave-number domain attenuation coefficient.

Authors:  Danqing He; Chaoxue Zhang; Wenqian Qiu; Qinxiu Xie
Journal:  Turk J Gastroenterol       Date:  2020-12       Impact factor: 1.852

5.  Use of a convolutional neural network and quantitative ultrasound for diagnosis of fatty liver.

Authors:  Trong N Nguyen; Anthony S Podkowa; Trevor H Park; Rita J Miller; Minh N Do; Michael L Oelze
Journal:  Ultrasound Med Biol       Date:  2020-12-25       Impact factor: 2.998

6.  Quantitative Ultrasound Radiofrequency Data Analysis for the Assessment of Hepatic Steatosis in Nonalcoholic Fatty Liver Disease Using Magnetic Resonance Imaging Proton Density Fat Fraction as the Reference Standard.

Authors:  Sun Kyung Jeon; Jeong Min Lee; Ijin Joo; Sae Jin Park
Journal:  Korean J Radiol       Date:  2021-03-09       Impact factor: 3.500

7.  Evaluation of muscular changes by ultrasound Nakagami imaging in Duchenne muscular dystrophy.

Authors:  Wen-Chin Weng; Po-Hsiang Tsui; Chia-Wei Lin; Chun-Hao Lu; Chun-Yen Lin; Jeng-Yi Shieh; Frank Leigh Lu; Ting-Wei Ee; Kuan-Wen Wu; Wang-Tso Lee
Journal:  Sci Rep       Date:  2017-06-30       Impact factor: 4.379

Review 8.  Quantitative ultrasound approaches for diagnosis and monitoring hepatic steatosis in nonalcoholic fatty liver disease.

Authors:  Amir M Pirmoazen; Aman Khurana; Ahmed El Kaffas; Aya Kamaya
Journal:  Theranostics       Date:  2020-03-04       Impact factor: 11.556

9.  Monitoring of Adult Zebrafish Heart Regeneration Using High-Frequency Ultrasound Spectral Doppler and Nakagami Imaging.

Authors:  Sunmi Yeo; Changhan Yoon; Ching-Ling Lien; Tai-Kyong Song; K Kirk Shung
Journal:  Sensors (Basel)       Date:  2019-09-22       Impact factor: 3.576

10.  Quantitative ultrasound radiofrequency data analysis for the assessment of hepatic steatosis using the controlled attenuation parameter as a reference standard.

Authors:  Sun Kyung Jeon; Ijin Joo; So Yeon Kim; Jong Keon Jang; Juil Park; Hee Sun Park; Eun Sun Lee; Jeong Min Lee
Journal:  Ultrasonography       Date:  2020-05-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.